3D-Encoded DENSE MRI with Zonal Excitation for Quantifying Biventricular Myocardial Strain During a Breath-Hold
© 2021. Biomedical Engineering Society..
PURPOSE: Right ventricular (RV) function is increasingly recognized for its prognostic value in many disease states. As with the left ventricle (LV), strain-based measurements may have better prognostic value than typical chamber volumes or ejection fraction. Complete functional characterization of the RV requires high-resolution, 3D displacement tracking methods, which have been prohibitively challenging to implement. Zonal excitation during Displacement ENcoding with Stimulated Echoes (DENSE) magnetic resonance imaging (MRI) has helped reduce scan time for 2D LV strain quantification. We hypothesized that zonal excitation could alternatively be used to reproducibly acquire higher resolution, 3D-encoded DENSE images for quantification of bi-ventricular strain within a single breath-hold.
METHODS: We modified sequence parameters for a 3D zonal excitation DENSE sequence to achieve in-plane resolution < 2 mm and acquired two sets of images in eight healthy adult male volunteers with median (IQR) age 32.5 (32.0-33.8) years. We assessed the inter-test reproducibility of this technique, and compared computed strains and torsion with previously published data.
RESULTS: Data for one subject was excluded based on image artifacts. Reproducibility for LV (CoV: 6.1-9.0%) and RV normal strains (CoV: 6.3-8.2%) and LV torsion (CoV = 7.1%) were all very good. Reproducibility of RV torsion was lower (CoV = 16.7%), but still within acceptable limits. Computed global strains and torsion were within reasonable agreement with published data, but further studies in larger cohorts are needed to confirm.
CONCLUSION: Reproducible acquisition of 3D-encoded biventricular myocardial strain data in a breath-hold is feasible using DENSE with zonal excitation.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:12 |
---|---|
Enthalten in: |
Cardiovascular engineering and technology - 12(2021), 6 vom: 09. Dez., Seite 589-597 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Carruth, Eric D [VerfasserIn] |
---|
Links: |
---|
Themen: |
DENSE |
---|
Anmerkungen: |
Date Completed 31.12.2021 Date Revised 02.12.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s13239-021-00561-8 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM327907533 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM327907533 | ||
003 | DE-627 | ||
005 | 20231225201823.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s13239-021-00561-8 |2 doi | |
028 | 5 | 2 | |a pubmed24n1092.xml |
035 | |a (DE-627)NLM327907533 | ||
035 | |a (NLM)34244904 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Carruth, Eric D |e verfasserin |4 aut | |
245 | 1 | 0 | |a 3D-Encoded DENSE MRI with Zonal Excitation for Quantifying Biventricular Myocardial Strain During a Breath-Hold |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 31.12.2021 | ||
500 | |a Date Revised 02.12.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2021. Biomedical Engineering Society. | ||
520 | |a PURPOSE: Right ventricular (RV) function is increasingly recognized for its prognostic value in many disease states. As with the left ventricle (LV), strain-based measurements may have better prognostic value than typical chamber volumes or ejection fraction. Complete functional characterization of the RV requires high-resolution, 3D displacement tracking methods, which have been prohibitively challenging to implement. Zonal excitation during Displacement ENcoding with Stimulated Echoes (DENSE) magnetic resonance imaging (MRI) has helped reduce scan time for 2D LV strain quantification. We hypothesized that zonal excitation could alternatively be used to reproducibly acquire higher resolution, 3D-encoded DENSE images for quantification of bi-ventricular strain within a single breath-hold | ||
520 | |a METHODS: We modified sequence parameters for a 3D zonal excitation DENSE sequence to achieve in-plane resolution < 2 mm and acquired two sets of images in eight healthy adult male volunteers with median (IQR) age 32.5 (32.0-33.8) years. We assessed the inter-test reproducibility of this technique, and compared computed strains and torsion with previously published data | ||
520 | |a RESULTS: Data for one subject was excluded based on image artifacts. Reproducibility for LV (CoV: 6.1-9.0%) and RV normal strains (CoV: 6.3-8.2%) and LV torsion (CoV = 7.1%) were all very good. Reproducibility of RV torsion was lower (CoV = 16.7%), but still within acceptable limits. Computed global strains and torsion were within reasonable agreement with published data, but further studies in larger cohorts are needed to confirm | ||
520 | |a CONCLUSION: Reproducible acquisition of 3D-encoded biventricular myocardial strain data in a breath-hold is feasible using DENSE with zonal excitation | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Research Support, N.I.H., Extramural | |
650 | 4 | |a DENSE | |
650 | 4 | |a Myocardial mechanics | |
650 | 4 | |a Right ventricle | |
650 | 4 | |a Zonal excitation | |
700 | 1 | |a Fielden, Samuel W |e verfasserin |4 aut | |
700 | 1 | |a Nevius, Christopher D |e verfasserin |4 aut | |
700 | 1 | |a Fornwalt, Brandon K |e verfasserin |4 aut | |
700 | 1 | |a Haggerty, Christopher M |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Cardiovascular engineering and technology |d 2010 |g 12(2021), 6 vom: 09. Dez., Seite 589-597 |w (DE-627)NLM199374163 |x 1869-4098 |7 nnns |
773 | 1 | 8 | |g volume:12 |g year:2021 |g number:6 |g day:09 |g month:12 |g pages:589-597 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s13239-021-00561-8 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 12 |j 2021 |e 6 |b 09 |c 12 |h 589-597 |