Covered stent placement for treatment of coarctation of the aorta : immediate and long-term results
OBJECTIVES: This study aimed to describe the safety and efficacy of covered stents in patients with coarctation of aorta (CoA) for immediate and long-term follow-up.
BACKGROUND: Covered stents are increasingly being used in (re)CoA, mainly to reduce the risk of aortic wall injuries (AWI). However, limited data are available on intermediate and long-term outcome.
METHODS: In 89 patients (67.4% male) with a mean age of 23.9 ± 15.8 (min max range 5.1-71.6) years were 102 covered stents implanted (January 2003 - December 2017). Short-term pre/post-implant hemodynamics and angiographic data were reported. Changes in blood pressure, the use of antihypertensive drugs and complications were recorded during follow-up.
RESULTS: The procedural success rate was 100%. The mean invasive ascending-to-descending aorta systolic gradient under general anaesthesia decreased from 25 ± 16 mmHg to 4 ± 7 mmHg (p < 0.001). After a mean follow-up time of 6.6 ± 3.7 years, there was a persistent improvement of the mean systolic blood pressure gradient between right arm and leg (-7 ± 18 vs 38 ± 24 mmHg; p < 0.001). A larger proportion of patients required antihypertensive medication (33.7% vs 50.0%, p = 0.017) and needed ≥ 2 drugs (20.2% vs 27.4%, p = 0.066) to control blood pressure. Long-term adverse events were found in 4.5% of patients [covered stent fracture (n = 3), aneurysm formation (n = 2)].
CONCLUSIONS: Covered stent implantation for CoA is highly successful, safe and results in a persistent hemodynamic improvement in the immediate and long-term outcome. Lifelong follow-up with additional antihypertensive drug treatment is mandatory to maintain favourable hemodynamic results after stenting.
CONDENSED ABSTRACT: Long-term follow-up data on covered stents in patients with coarctation of the aorta are scarce. A cohort of 89 patients was reviewed. The procedural implantation success rate was 100%. The invasive gradient decreased from 25 ± 16 mmHg to 4 ± 7 mmHg (p < 0.001). After follow-up of 6.6 ± 3.7 years, there was a persistent improvement of the clinical systolic blood pressure gradient (-7 ± 18 vs 38 ± 24 mmHg; p < 0.001). However, a larger proportion of patients required antihypertensive medication (33.7% vs 50.0%, p = 0.017). Covered stent implantation results in favourable hemodynamic effects, but lifelong follow-up with additional antihypertensive drug treatment is mandatory to maintain these results.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:76 |
---|---|
Enthalten in: |
Acta cardiologica - 76(2021), 5 vom: 03. Juli, Seite 464-472 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Stassen, Jan [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 25.11.2021 Date Revised 24.04.2022 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1080/00015385.2020.1838126 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM316776416 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM316776416 | ||
003 | DE-627 | ||
005 | 20231225161818.0 | ||
007 | cr uuu---uuuuu | ||
008 | 231225s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1080/00015385.2020.1838126 |2 doi | |
028 | 5 | 2 | |a pubmed24n1055.xml |
035 | |a (DE-627)NLM316776416 | ||
035 | |a (NLM)33108973 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Stassen, Jan |e verfasserin |4 aut | |
245 | 1 | 0 | |a Covered stent placement for treatment of coarctation of the aorta |b immediate and long-term results |
264 | 1 | |c 2021 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 25.11.2021 | ||
500 | |a Date Revised 24.04.2022 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a OBJECTIVES: This study aimed to describe the safety and efficacy of covered stents in patients with coarctation of aorta (CoA) for immediate and long-term follow-up | ||
520 | |a BACKGROUND: Covered stents are increasingly being used in (re)CoA, mainly to reduce the risk of aortic wall injuries (AWI). However, limited data are available on intermediate and long-term outcome | ||
520 | |a METHODS: In 89 patients (67.4% male) with a mean age of 23.9 ± 15.8 (min max range 5.1-71.6) years were 102 covered stents implanted (January 2003 - December 2017). Short-term pre/post-implant hemodynamics and angiographic data were reported. Changes in blood pressure, the use of antihypertensive drugs and complications were recorded during follow-up | ||
520 | |a RESULTS: The procedural success rate was 100%. The mean invasive ascending-to-descending aorta systolic gradient under general anaesthesia decreased from 25 ± 16 mmHg to 4 ± 7 mmHg (p < 0.001). After a mean follow-up time of 6.6 ± 3.7 years, there was a persistent improvement of the mean systolic blood pressure gradient between right arm and leg (-7 ± 18 vs 38 ± 24 mmHg; p < 0.001). A larger proportion of patients required antihypertensive medication (33.7% vs 50.0%, p = 0.017) and needed ≥ 2 drugs (20.2% vs 27.4%, p = 0.066) to control blood pressure. Long-term adverse events were found in 4.5% of patients [covered stent fracture (n = 3), aneurysm formation (n = 2)] | ||
520 | |a CONCLUSIONS: Covered stent implantation for CoA is highly successful, safe and results in a persistent hemodynamic improvement in the immediate and long-term outcome. Lifelong follow-up with additional antihypertensive drug treatment is mandatory to maintain favourable hemodynamic results after stenting | ||
520 | |a CONDENSED ABSTRACT: Long-term follow-up data on covered stents in patients with coarctation of the aorta are scarce. A cohort of 89 patients was reviewed. The procedural implantation success rate was 100%. The invasive gradient decreased from 25 ± 16 mmHg to 4 ± 7 mmHg (p < 0.001). After follow-up of 6.6 ± 3.7 years, there was a persistent improvement of the clinical systolic blood pressure gradient (-7 ± 18 vs 38 ± 24 mmHg; p < 0.001). However, a larger proportion of patients required antihypertensive medication (33.7% vs 50.0%, p = 0.017). Covered stent implantation results in favourable hemodynamic effects, but lifelong follow-up with additional antihypertensive drug treatment is mandatory to maintain these results | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Coarctation | |
650 | 4 | |a congenital | |
650 | 4 | |a covered | |
650 | 4 | |a stent | |
700 | 1 | |a De Meester, Pieter |e verfasserin |4 aut | |
700 | 1 | |a Troost, Els |e verfasserin |4 aut | |
700 | 1 | |a Roggen, Leen |e verfasserin |4 aut | |
700 | 1 | |a Moons, Philip |e verfasserin |4 aut | |
700 | 1 | |a Gewillig, Marc |e verfasserin |4 aut | |
700 | 1 | |a Van De Bruaene, Alexander |e verfasserin |4 aut | |
700 | 1 | |a Budts, Werner |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Acta cardiologica |d 1946 |g 76(2021), 5 vom: 03. Juli, Seite 464-472 |w (DE-627)NLM000152854 |x 1784-973X |7 nnns |
773 | 1 | 8 | |g volume:76 |g year:2021 |g number:5 |g day:03 |g month:07 |g pages:464-472 |
856 | 4 | 0 | |u http://dx.doi.org/10.1080/00015385.2020.1838126 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 76 |j 2021 |e 5 |b 03 |c 07 |h 464-472 |