An in-depth Analysis on Four Classes of Antidepressants Quantification from Human Serum using LC-MS/MS
Abstract Depression is a growing global crisis, with females at a higher rate of diagnosis than males. While the percentage of patients on prescribed antidepressants have tripled over the last two decades, we are still at a crossroad where discrepancy lies between finding a drug to suit a patient and monitoring the abundance of it in the body to prevent unwanted side-effects. Liquid Chromatography tandem mass spectrometry (LC-MS/MS) has garnered the attention of clinicians as a technique to accurately monitor therapeutic drugs in human serum with high specificity and accuracy. This may be a potential solution, but challenge persists in the realm of sample preparation where a method is automatable. We have developed and validated an LC-MS/MS-based assay for simultaneous quantification of 5-different classes of the commonly prescribed antidepressants in women, that is automated using a JANUS® G3 Robotic Liquid Handler. Our method utilizes a simple sample preparation technique, utilizing only 20 μL of serum sample, to accurately measure Bupropion, Citalopram, Desipramine, Imipramine, Olanzapine, Sertraline and Vilazodone across a range of 1.0 to 230 ng/mL. Our method exhibits a linearity of R2 ≥0.99 when detected in MRM mode, and % CV of ≤20% for all analytes across the board. In addition, we have designed a prototype that can be utilized at a clinical mass spectrometry lab, and we have assessed the long-term use of this prototype using an accelerated stability study. Overall, our developed method has the potential to be translated to clinical settings to monitor post-partum depression for large number of patient samples using automation..
Medienart: |
Preprint |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
ResearchSquare.com - (2022) vom: 21. Nov. Zur Gesamtaufnahme - year:2022 |
---|
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Fariha, Ramisa [VerfasserIn] |
---|
Links: |
Volltext [kostenfrei] |
---|
Themen: |
---|
doi: |
10.21203/rs.3.rs-2282174/v1 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
XRA037935984 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | XRA037935984 | ||
003 | DE-627 | ||
005 | 20230429182314.0 | ||
007 | cr uuu---uuuuu | ||
008 | 221122s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.21203/rs.3.rs-2282174/v1 |2 doi | |
035 | |a (DE-627)XRA037935984 | ||
035 | |a (ResearchSquare)10.21203/rs.3.rs-2282174/v1 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Fariha, Ramisa |e verfasserin |4 aut | |
245 | 1 | 0 | |a An in-depth Analysis on Four Classes of Antidepressants Quantification from Human Serum using LC-MS/MS |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Abstract Depression is a growing global crisis, with females at a higher rate of diagnosis than males. While the percentage of patients on prescribed antidepressants have tripled over the last two decades, we are still at a crossroad where discrepancy lies between finding a drug to suit a patient and monitoring the abundance of it in the body to prevent unwanted side-effects. Liquid Chromatography tandem mass spectrometry (LC-MS/MS) has garnered the attention of clinicians as a technique to accurately monitor therapeutic drugs in human serum with high specificity and accuracy. This may be a potential solution, but challenge persists in the realm of sample preparation where a method is automatable. We have developed and validated an LC-MS/MS-based assay for simultaneous quantification of 5-different classes of the commonly prescribed antidepressants in women, that is automated using a JANUS® G3 Robotic Liquid Handler. Our method utilizes a simple sample preparation technique, utilizing only 20 μL of serum sample, to accurately measure Bupropion, Citalopram, Desipramine, Imipramine, Olanzapine, Sertraline and Vilazodone across a range of 1.0 to 230 ng/mL. Our method exhibits a linearity of R2 ≥0.99 when detected in MRM mode, and % CV of ≤20% for all analytes across the board. In addition, we have designed a prototype that can be utilized at a clinical mass spectrometry lab, and we have assessed the long-term use of this prototype using an accelerated stability study. Overall, our developed method has the potential to be translated to clinical settings to monitor post-partum depression for large number of patient samples using automation. | ||
650 | 4 | |a Biology |7 (dpeaa)DE-84 | |
650 | 4 | |a 570 |7 (dpeaa)DE-84 | |
700 | 1 | |a Deshpande, Prutha Sameer |e verfasserin |4 aut | |
700 | 1 | |a Rothkopf, Emma |e verfasserin |4 aut | |
700 | 1 | |a Jabrah, Mohannad |e verfasserin |4 aut | |
700 | 1 | |a Spooner, Adam |e verfasserin |4 aut | |
700 | 1 | |a Okoh, Oluwanifemi David |e verfasserin |4 aut | |
700 | 1 | |a Tripathi, Anubhav |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t ResearchSquare.com |g (2022) vom: 21. Nov. |
773 | 1 | 8 | |g year:2022 |g day:21 |g month:11 |
856 | 4 | 0 | |u http://dx.doi.org/10.21203/rs.3.rs-2282174/v1 |z kostenfrei |3 Volltext |
912 | |a GBV_XRA | ||
912 | |a SSG-OLC-PHA | ||
951 | |a AR | ||
952 | |j 2022 |b 21 |c 11 |