Wide-vergence, multi-spectral adaptive optics scanning laser ophthalmoscope with diffraction-limited illumination and collection

Abstract Visualizing and assessing the function of microscopic retinal structures in the human eye is a challenging task that has been greatly facilitated by ophthalmic adaptive optics (AO). Yet, as AO imaging systems advance in functionality by employing multiple spectral channels and larger vergence ranges, achieving optimal resolution and signal-to-noise ratios (SNR) becomes difficult and is often compromised. While current-generation AO retinal imaging systems have demonstrated excellent, near diffraction-limited imaging performance over wide vergence and spectral ranges, a full theoretical and experimental analysis of an AOSLO that includes both the light delivery and collection optics has not been done, and neither has the effects of extending wavefront correction from one wavelength to imaging performance in different spectral channels. Here, we report a methodology and system design for simultaneously achieving diffraction-limited performance in both the illumination and collection paths for a wide-vergence, multi-spectral AO scanning laser ophthalmoscope (SLO) over a 1.2 diopter vergence range while correcting the wavefront in a separate wavelength. To validate the design, an AOSLO was constructed to have three imaging channels spanning different wavelength ranges (543 ± 11 nm, 680 ± 11 nm, and 840 ± 6 nm, respectively) and one near-infrared wavefront sensing channel (940 ± 5 nm). The AOSLO optics and their alignment were determined via simulations in optical and optomechanical design software and then experimentally verified by measuring the AOSLO’s illumination and collection point spread functions (PSF) for each channel using a phase retrieval technique. The collection efficiency was then measured for each channel as a function of confocal pinhole size when imaging a model eye achieving near-theoretical performance. Imaging results from healthy human adult volunteers demonstrate the system’s ability to resolve the foveal cone mosaic in all three imaging channels despite a wide spectral separation between the wavefront sensing and imaging channels.OCIS codes (110.1080) Active or adaptive optics; (170.4460) Ophthalmic optics and devices; (170.4470) Ophthalmology.

Medienart:

Preprint

Erscheinungsjahr:

2020

Erschienen:

2020

Enthalten in:

bioRxiv.org - (2020) vom: 02. Juni Zur Gesamtaufnahme - year:2020

Sprache:

Englisch

Beteiligte Personen:

Mozaffari, Sanam [VerfasserIn]
Larocca, Francesco [VerfasserIn]
Jaedicke, Volker [VerfasserIn]
Tiruveedhula, Pavan [VerfasserIn]
Roorda, Austin [VerfasserIn]

Links:

Volltext [lizenzpflichtig]
Volltext [kostenfrei]

doi:

10.1101/2020.01.29.924969

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

XBI000717282