Coronavirus disease 2019 pandemic and identifying insufflators with desufflation mode and surgical smoke evacuators for safe CO2 removal
Abstract Introduction Given the propensity of severe acute respiratory syndrome coronavirus 2 to spread, it is imperative that those continuing to perform surgery take precautions to limit the potential generation of contaminated aerosols in smoke from energy‐based instruments. The aim of this study was to report current data regarding insufflators with desufflation mode and similar options to safely remove CO2 in minimal access surgery. Methods A non‐systematic review of the scientific literature was conducted using the PubMed database, and the main companies that provide surgical devices were contacted for information. Results Most commercially available smoke evacuators use a combination of suction and mechanical filtering. There are also electrostatic precipitators that charge surgical smoke and retain the particles via electrostatic attraction. The search identified three insufflators with desufflation mode, four modular smoke evacuators using mechanical filtration, and only one device using electrostatic precipitation. However, none of these devices has been tested with viruses. Conclusion This review identified commercially available equipment that employs mechanical filtering and electrostatic attraction principles that can be used for pneumoperitoneum evacuation during the present coronavirus disease 2019 pandemic. This pandemic should assist in raising awareness regarding protection measures and the risk of occupational exposure in surgery..
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2021 |
---|---|
Erschienen: |
2021 |
Enthalten in: |
Zur Gesamtaufnahme - volume:14 |
---|---|
Enthalten in: |
Asian Journal of Endoscopic Surgery - 14(2021), 2, Seite 165-169 |
Beteiligte Personen: |
da Costa, Karina M. [VerfasserIn] |
---|
BKL: |
---|
Anmerkungen: |
© 2021 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd |
---|
Umfang: |
5 |
---|
doi: |
10.1111/ases.12834 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
WLY00245730X |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | WLY00245730X | ||
003 | DE-627 | ||
005 | 20230307115336.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230211s2021 xx |||||o 00| ||und c | ||
024 | 7 | |a 10.1111/ases.12834 |2 doi | |
028 | 5 | 2 | |a ASES_ASES12834.xml |
035 | |a (DE-627)WLY00245730X | ||
035 | |a (WILEY)ASES12834 | ||
040 | |a DE-627 |b ger |c DE-627 |e rda | ||
082 | 0 | 4 | |a 610 |q ASE |
084 | |a 44.65 |2 bkl | ||
100 | 1 | |a da Costa, Karina M. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Coronavirus disease 2019 pandemic and identifying insufflators with desufflation mode and surgical smoke evacuators for safe CO2 removal |
264 | 1 | |c 2021 | |
300 | |a 5 | ||
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a © 2021 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd | ||
520 | |a Abstract Introduction Given the propensity of severe acute respiratory syndrome coronavirus 2 to spread, it is imperative that those continuing to perform surgery take precautions to limit the potential generation of contaminated aerosols in smoke from energy‐based instruments. The aim of this study was to report current data regarding insufflators with desufflation mode and similar options to safely remove CO2 in minimal access surgery. Methods A non‐systematic review of the scientific literature was conducted using the PubMed database, and the main companies that provide surgical devices were contacted for information. Results Most commercially available smoke evacuators use a combination of suction and mechanical filtering. There are also electrostatic precipitators that charge surgical smoke and retain the particles via electrostatic attraction. The search identified three insufflators with desufflation mode, four modular smoke evacuators using mechanical filtration, and only one device using electrostatic precipitation. However, none of these devices has been tested with viruses. Conclusion This review identified commercially available equipment that employs mechanical filtering and electrostatic attraction principles that can be used for pneumoperitoneum evacuation during the present coronavirus disease 2019 pandemic. This pandemic should assist in raising awareness regarding protection measures and the risk of occupational exposure in surgery. | ||
700 | 1 | |a Saxena, Amulya K. |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Asian Journal of Endoscopic Surgery |g 14(2021), 2, Seite 165-169 |w (DE-627)WLY002456087 |x 17585910 |7 nnns |
773 | 1 | 8 | |g volume:14 |g year:2021 |g number:2 |g pages:165-169 |g extent:5 |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_WLY | ||
936 | b | k | |a 44.65 |q ASE |
951 | |a AR | ||
952 | |d 14 |j 2021 |e 2 |h 165-169 |g 5 |