Intraosseous pressure measurement during iliac bone marrow biopsy: its feasibility and difference of IOP in diseased marrow and non-diseased marrow
Objective The purposes of this study were (1) to establish the feasibility and safety of an imaging-guided technique for intraosseous pressure (IOP) measurement in a large cohort of patients, and (2) to compare IOP values between normal and diseased bone marrow. Methods Adult patients undergoing CT-guided marrow biopsy were prospectively and consecutively enrolled from November 2020 to February 2022. IOP measurements were obtained connecting the biopsy needle to a monitoring device using a standard arterial line setup. Clinical data including sex, age and pathology results were obtained. Student t test and Pearson correlation were used for continuous variables comparisons. Univariable analyses were performed using Fisher’s exact test. A P value of .05 was considered statistically significant. Results A total of 139 participants were initially enrolled, and four were excluded during technique optimization. There were no complications related to the measurement technique. Ninety participants (90/135, 67%) had histology confirming marrow pathology. The participants in the diseased marrow group were older than those in the normal marrow group (63 ± 14 vs. 55 ± 14 years; P < .01). There was no difference in mean IOP between both groups (66 ± 23 vs. 64 ± 28 mmHg; P = .69). There was no correlation between mean arterial blood pressure and mean IOP (P = .08). Conclusion There was no difference in IOP measurements between patients with normal and diseased marrow undergoing CT-guided biopsy. IOP does not appear to be influenced by systemic blood pressure. No complication occurred during the procedures..
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:53 |
---|---|
Enthalten in: |
Skeletal radiology - 53(2023), 3 vom: 28. Aug., Seite 481-487 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Vicentini, Joao Rafael T. [VerfasserIn] |
---|
Links: |
Volltext [lizenzpflichtig] |
---|
Themen: |
---|
Anmerkungen: |
© The Author(s), under exclusive licence to International Skeletal Society (ISS) 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. |
---|
doi: |
10.1007/s00256-023-04431-3 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
SPR054319196 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | SPR054319196 | ||
003 | DE-627 | ||
005 | 20240110064634.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240110s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00256-023-04431-3 |2 doi | |
035 | |a (DE-627)SPR054319196 | ||
035 | |a (SPR)s00256-023-04431-3-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Vicentini, Joao Rafael T. |e verfasserin |0 (orcid)0000-0002-0838-1659 |4 aut | |
245 | 1 | 0 | |a Intraosseous pressure measurement during iliac bone marrow biopsy: its feasibility and difference of IOP in diseased marrow and non-diseased marrow |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a © The Author(s), under exclusive licence to International Skeletal Society (ISS) 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. | ||
520 | |a Objective The purposes of this study were (1) to establish the feasibility and safety of an imaging-guided technique for intraosseous pressure (IOP) measurement in a large cohort of patients, and (2) to compare IOP values between normal and diseased bone marrow. Methods Adult patients undergoing CT-guided marrow biopsy were prospectively and consecutively enrolled from November 2020 to February 2022. IOP measurements were obtained connecting the biopsy needle to a monitoring device using a standard arterial line setup. Clinical data including sex, age and pathology results were obtained. Student t test and Pearson correlation were used for continuous variables comparisons. Univariable analyses were performed using Fisher’s exact test. A P value of .05 was considered statistically significant. Results A total of 139 participants were initially enrolled, and four were excluded during technique optimization. There were no complications related to the measurement technique. Ninety participants (90/135, 67%) had histology confirming marrow pathology. The participants in the diseased marrow group were older than those in the normal marrow group (63 ± 14 vs. 55 ± 14 years; P < .01). There was no difference in mean IOP between both groups (66 ± 23 vs. 64 ± 28 mmHg; P = .69). There was no correlation between mean arterial blood pressure and mean IOP (P = .08). Conclusion There was no difference in IOP measurements between patients with normal and diseased marrow undergoing CT-guided biopsy. IOP does not appear to be influenced by systemic blood pressure. No complication occurred during the procedures. | ||
650 | 4 | |a Intraosseous pressure |7 (dpeaa)DE-He213 | |
650 | 4 | |a CT-guided biopsy |7 (dpeaa)DE-He213 | |
650 | 4 | |a Marrow pathology |7 (dpeaa)DE-He213 | |
700 | 1 | |a Habibollahi, Sina |4 aut | |
700 | 1 | |a Habib, Ukasha |4 aut | |
700 | 1 | |a Chang, Connie Y. |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Skeletal radiology |d Berlin : Springer, 1976 |g 53(2023), 3 vom: 28. Aug., Seite 481-487 |w (DE-627)SPR003067432 |w (DE-600)1461957-X |x 1432-2161 |7 nnns |
773 | 1 | 8 | |g volume:53 |g year:2023 |g number:3 |g day:28 |g month:08 |g pages:481-487 |
856 | 4 | 0 | |u https://dx.doi.org/10.1007/s00256-023-04431-3 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_SPRINGER | ||
951 | |a AR | ||
952 | |d 53 |j 2023 |e 3 |b 28 |c 08 |h 481-487 |