Retrospective observational study of diagnostic accuracy of the Xpert® MTB/RIF assay on fiberoptic bronchoscopy sampling for early diagnosis of smear-negative or sputum-scarce patients with suspected tuberculosis

Background Fiberoptic bronchoscopy (FOB) is a useful diagnosis tool in low-burden countries for patients with suspected pulmonary tuberculosis (TB) who are smear-negative or sputum-scarce. This study sought to determine the accuracy of the Xpert® MTB/RIF (XP) assay using FOB samples. Methods We retrospectively reviewed clinical, radiological, and microbiological characteristics of 175 TB-suspected patients requiring diagnostic FOB (bronchial aspirate or bronchoalveolar lavage) with XP assay. Polymerase chain reaction (PCR) and smear microscopy (SM) performances were first compared to culture, then to the final diagnosis, established based on clinical or radiological evolution when cultures were negative. Results Of the total 162 included patients, 30 (18.5%) had a final diagnosis of pulmonary TB, with positive cultures reported in 23. As compared to culture, sensitivity and specificity values were 80.0% and 98.6% for the XP assay, and 25.0% and 95.8% for SM, respectively. As compared to final diagnosis, the corresponding performance values were 60.0% and 100.0% for the XP assay, and 16.7% and 95.5% for SM, respectively. The sensitivity of the XP assay was significantly higher than that of SM in both cases (p = 0.003 and p = 0.001). Concerning the final diagnosis, both XP assay and culture sensitivities were similar (60% vs. 66.7%). PCR assay enabled pulmonary TB to be diagnosed earlier in 13 more cases, compared to SM. Conclusion Our study has confirmed the clinical benefits provided by XP assay compared to SM for the early diagnosis of suspected pulmonary TB cases requiring FOB, on per procedure samples, especially in a low TB-burden country..

Medienart:

E-Artikel

Erscheinungsjahr:

2014

Erschienen:

2014

Enthalten in:

Zur Gesamtaufnahme - volume:14

Enthalten in:

BMC pulmonary medicine - 14(2014), 1 vom: 12. Aug.

Sprache:

Englisch

Beteiligte Personen:

Le Palud, Pierre [VerfasserIn]
Cattoir, Vincent [VerfasserIn]
Malbruny, Brigitte [VerfasserIn]
Magnier, Romain [VerfasserIn]
Campbell, Karine [VerfasserIn]
Oulkhouir, Youssef [VerfasserIn]
Zalcman, Gérard [VerfasserIn]
Bergot, Emmanuel [VerfasserIn]

Links:

Volltext [lizenzpflichtig]

Themen:

Fiberoptic bronchoscopy
Smear microscopy
Tuberculosis diagnosis
Xpert® MTB/RIF assay

Anmerkungen:

© Le Palud et al.; licensee BioMed Central Ltd. 2014. This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (

doi:

10.1186/1471-2466-14-137

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

SPR027990788