Implementation of Continuous Glucose Monitoring in Critical Care: A Scoping Review
Purpose of Review The aim of this review is to identify the implementation approaches, strategies, and outcomes for continuous glucose monitoring (CGM) in the intensive care unit (ICU). Medline and Web of Science databases were searched to report relevant literature published between September 12, 2016 and September 12, 2021. Implementation outcomes and strategies, defined by the Expert Recommendations for Implementing Change (ERIC) project, were extracted. Recent Findings Of the 324 titles reviewed, 16 articles were included in the review. While no studies were identified as implementation research, 14 of 16 identified implementation strategies that aligned with ERIC definitions. Included studies described a multi-disciplinary approach. Clinical outcomes included Mean Absolute Relative Difference (MARD), ranging from 7.5 to 15.3%, and 33–71% reduction in frequency of point-of-care (POC) blood glucose monitoring (BGM) using hybrid protocols. Summary This scoping review provides valuable insight into the process of CGM implementation in the ICU. Continued research should include implementation outcomes to inform widespread utilization..
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:23 |
---|---|
Enthalten in: |
Current diabetes reports - 23(2023), 6 vom: 13. Apr., Seite 69-87 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Faulds, Eileen R. [VerfasserIn] |
---|
Links: |
Volltext [lizenzpflichtig] |
---|
Themen: |
Continuous glucose monitoring |
---|
Anmerkungen: |
© The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. |
---|
doi: |
10.1007/s11892-023-01503-5 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
OLC2134819286 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | OLC2134819286 | ||
003 | DE-627 | ||
005 | 20230510163843.0 | ||
007 | tu | ||
008 | 230510s2023 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1007/s11892-023-01503-5 |2 doi | |
035 | |a (DE-627)OLC2134819286 | ||
035 | |a (DE-He213)s11892-023-01503-5-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q VZ |
100 | 1 | |a Faulds, Eileen R. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Implementation of Continuous Glucose Monitoring in Critical Care: A Scoping Review |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. | ||
520 | |a Purpose of Review The aim of this review is to identify the implementation approaches, strategies, and outcomes for continuous glucose monitoring (CGM) in the intensive care unit (ICU). Medline and Web of Science databases were searched to report relevant literature published between September 12, 2016 and September 12, 2021. Implementation outcomes and strategies, defined by the Expert Recommendations for Implementing Change (ERIC) project, were extracted. Recent Findings Of the 324 titles reviewed, 16 articles were included in the review. While no studies were identified as implementation research, 14 of 16 identified implementation strategies that aligned with ERIC definitions. Included studies described a multi-disciplinary approach. Clinical outcomes included Mean Absolute Relative Difference (MARD), ranging from 7.5 to 15.3%, and 33–71% reduction in frequency of point-of-care (POC) blood glucose monitoring (BGM) using hybrid protocols. Summary This scoping review provides valuable insight into the process of CGM implementation in the ICU. Continued research should include implementation outcomes to inform widespread utilization. | ||
650 | 4 | |a Continuous glucose monitoring | |
650 | 4 | |a Inpatient | |
650 | 4 | |a Hospitalized | |
650 | 4 | |a Intensive care unit | |
650 | 4 | |a Implementation science | |
650 | 4 | |a Glucose monitoring | |
700 | 1 | |a Dungan, Kathleen M. |4 aut | |
700 | 1 | |a McNett, Molly |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Current diabetes reports |d Springer US, 2001 |g 23(2023), 6 vom: 13. Apr., Seite 69-87 |w (DE-627)340076372 |w (DE-600)2065167-3 |x 1534-4827 |7 nnns |
773 | 1 | 8 | |g volume:23 |g year:2023 |g number:6 |g day:13 |g month:04 |g pages:69-87 |
856 | 4 | 1 | |u https://doi.org/10.1007/s11892-023-01503-5 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
951 | |a AR | ||
952 | |d 23 |j 2023 |e 6 |b 13 |c 04 |h 69-87 |