Right ventricular diastolic function in aging: a head-to-head comparison between phase-contrast MRI and Doppler echocardiography
Abstract To evaluate right ventricle (RV) diastolic function from phase-contrast MRI (PC-MRI) in aging. 89 healthy individuals (50 men, 43 ± 15 years) underwent cardiac MRI including 2D PC-MRI (1.5T) and reference Doppler echocardiography of both ventricles on the same day. Conventional echocardiographic parameters were estimated: early (E, cm/s) and atrial (A) peak velocities as well as myocardial early peak longitudinal velocity (E′). PC-MRI images were analyzed using custom software, providing: E′, E and A waves along with respective peak flow rates (Ef, Af, mL/s) and filling volume (mL), for both ventricles. Intra- and inter-observer reproducibility was studied in 30 subjects and coefficients of variation (CoV) as well as intra-class correlation coefficients (ICC) were provided. RV diastolic function indices derived from PC-MRI data were reproducible (CoV ≤ 21%, ICC ≥ 0.75) and reliable as reflected by significant associations with left ventricular diastolic function indices assessed using both echocardiography (linear regression Pearson correlation coefficient r ≤ 0.59) and PC-MRI (r ≤ 71). Despite the fair associations between RV echocardiography and PC-MRI (r ≤ 0.25), the highest correlation with age was obtained for MRI Ef/Af ratio (r = − 0.64, p < 0.0001 vs. r = − 0.40, p = 0.0001 for echocardiographic E/A). Among PC-MRI E/A ratios, highest correlations with age were observed for flow rate and mean velocity ratios (r = − 0.61, p < 0.0001) as compared to maximal velocity ratios (r = − 0.56, p < 0.0001). Associations with age for E′ were equivalent between PC-MRI (mean velocity: r = − 0.40, p < 0.0001; maximal velocity: r = − 0.36, p = 0.0005) and echocardiography (r = − 0.36, p = 0.0006). Finally, the significant and age-independent associations between RV mass/end-diastolic volume and E′ were stronger for PC-MRI (mean velocity: r = − 0.36, p = 0.0006; maximal velocity: r = − 0.28, p = 0.007) than echocardiography (r = − 0.09, p = 0.38). PC-MRI tricuspid inflow and annulus myocardial velocity parameters were reproducible and able to characterize age-related variations in RV diastolic function..
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2020 |
---|---|
Erschienen: |
2020 |
Enthalten in: |
Zur Gesamtaufnahme - volume:37 |
---|---|
Enthalten in: |
The international journal of cardiovascular imaging - 37(2020), 2 vom: 27. Sept., Seite 663-674 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Kachenoura, Nadjia [VerfasserIn] |
---|
Links: |
Volltext [lizenzpflichtig] |
---|
BKL: | |
---|---|
Themen: |
Anmerkungen: |
© Springer Nature B.V. 2020 |
---|
doi: |
10.1007/s10554-020-02040-y |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
OLC2123880752 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2123880752 | ||
003 | DE-627 | ||
005 | 20240321211735.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230505s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s10554-020-02040-y |2 doi | |
035 | |a (DE-627)OLC2123880752 | ||
035 | |a (DE-He213)s10554-020-02040-y-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q VZ |
084 | |a 44.85 |2 bkl | ||
084 | |a 44.64 |2 bkl | ||
100 | 1 | |a Kachenoura, Nadjia |e verfasserin |4 aut | |
245 | 1 | 0 | |a Right ventricular diastolic function in aging: a head-to-head comparison between phase-contrast MRI and Doppler echocardiography |
264 | 1 | |c 2020 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a © Springer Nature B.V. 2020 | ||
520 | |a Abstract To evaluate right ventricle (RV) diastolic function from phase-contrast MRI (PC-MRI) in aging. 89 healthy individuals (50 men, 43 ± 15 years) underwent cardiac MRI including 2D PC-MRI (1.5T) and reference Doppler echocardiography of both ventricles on the same day. Conventional echocardiographic parameters were estimated: early (E, cm/s) and atrial (A) peak velocities as well as myocardial early peak longitudinal velocity (E′). PC-MRI images were analyzed using custom software, providing: E′, E and A waves along with respective peak flow rates (Ef, Af, mL/s) and filling volume (mL), for both ventricles. Intra- and inter-observer reproducibility was studied in 30 subjects and coefficients of variation (CoV) as well as intra-class correlation coefficients (ICC) were provided. RV diastolic function indices derived from PC-MRI data were reproducible (CoV ≤ 21%, ICC ≥ 0.75) and reliable as reflected by significant associations with left ventricular diastolic function indices assessed using both echocardiography (linear regression Pearson correlation coefficient r ≤ 0.59) and PC-MRI (r ≤ 71). Despite the fair associations between RV echocardiography and PC-MRI (r ≤ 0.25), the highest correlation with age was obtained for MRI Ef/Af ratio (r = − 0.64, p < 0.0001 vs. r = − 0.40, p = 0.0001 for echocardiographic E/A). Among PC-MRI E/A ratios, highest correlations with age were observed for flow rate and mean velocity ratios (r = − 0.61, p < 0.0001) as compared to maximal velocity ratios (r = − 0.56, p < 0.0001). Associations with age for E′ were equivalent between PC-MRI (mean velocity: r = − 0.40, p < 0.0001; maximal velocity: r = − 0.36, p = 0.0005) and echocardiography (r = − 0.36, p = 0.0006). Finally, the significant and age-independent associations between RV mass/end-diastolic volume and E′ were stronger for PC-MRI (mean velocity: r = − 0.36, p = 0.0006; maximal velocity: r = − 0.28, p = 0.007) than echocardiography (r = − 0.09, p = 0.38). PC-MRI tricuspid inflow and annulus myocardial velocity parameters were reproducible and able to characterize age-related variations in RV diastolic function. | ||
650 | 4 | |a Phase-contrast MRI | |
650 | 4 | |a Right ventricle | |
650 | 4 | |a Diastolic function | |
650 | 4 | |a Aging | |
700 | 1 | |a Bollache, Emilie |4 aut | |
700 | 1 | |a Soulat, Gilles |4 aut | |
700 | 1 | |a Clément-Guinaudeau, Stéphanie |4 aut | |
700 | 1 | |a Ashrafpoor, Golmehr |4 aut | |
700 | 1 | |a Perdrix, Ludivine |4 aut | |
700 | 1 | |a Diebold, Benoit |4 aut | |
700 | 1 | |a Ladouceur, Magalie |4 aut | |
700 | 1 | |a Mousseaux, Elie |4 aut | |
773 | 0 | 8 | |i Enthalten in |t The international journal of cardiovascular imaging |d Springer Netherlands, 2001 |g 37(2020), 2 vom: 27. Sept., Seite 663-674 |h Online-Ressource |w (DE-627)320474321 |w (DE-600)2008950-8 |w (DE-576)121190994 |x 1875-8312 |7 nnns |
773 | 1 | 8 | |g volume:37 |g year:2020 |g number:2 |g day:27 |g month:09 |g pages:663-674 |
856 | 4 | 0 | |u https://dx.doi.org/10.1007/s10554-020-02040-y |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_11 | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_101 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_120 | ||
912 | |a GBV_ILN_138 | ||
912 | |a GBV_ILN_150 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_152 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_171 | ||
912 | |a GBV_ILN_187 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_224 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_250 | ||
912 | |a GBV_ILN_281 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_636 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_711 | ||
912 | |a GBV_ILN_2001 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2004 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2007 | ||
912 | |a GBV_ILN_2008 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2010 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2026 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2031 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2037 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2039 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2049 | ||
912 | |a GBV_ILN_2050 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2057 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2088 | ||
912 | |a GBV_ILN_2093 | ||
912 | |a GBV_ILN_2106 | ||
912 | |a GBV_ILN_2107 | ||
912 | |a GBV_ILN_2110 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2112 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2136 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2144 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2148 | ||
912 | |a GBV_ILN_2152 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2188 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2232 | ||
912 | |a GBV_ILN_2336 | ||
912 | |a GBV_ILN_2446 | ||
912 | |a GBV_ILN_2470 | ||
912 | |a GBV_ILN_2472 | ||
912 | |a GBV_ILN_2474 | ||
912 | |a GBV_ILN_2507 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_2548 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4046 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4246 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4251 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4326 | ||
912 | |a GBV_ILN_4328 | ||
912 | |a GBV_ILN_4333 | ||
912 | |a GBV_ILN_4334 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4336 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4393 | ||
912 | |a GBV_ILN_4700 | ||
936 | b | k | |a 44.85 |j Kardiologie |j Angiologie |j Kardiologie |j Angiologie |q VZ |
936 | b | k | |a 44.64 |j Radiologie |j Radiologie |q VZ |
951 | |a AR | ||
952 | |d 37 |j 2020 |e 2 |b 27 |c 09 |h 663-674 |