High-pitch dual-source CT coronary angiography with low volumes of contrast medium
Objectives To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). Methods One-hundred consecutive patients (body weight 65–85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/$ m^{2} $) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes ($ G_{30} $, 30 mL; $ G_{40} $, 40 mL; $ G_{50} $, 50 mL; $ G_{60} $, 60 mL; $ G_{70} $, 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Results Mean attenuation for men and women ranged from 345.0 and 399.1 HU in $ G_{30} $ to 478.2 and 571.8 HU in $ G_{70} $. Mean attenuation values were higher in groups with higher CM volumes (P < 0.0001) and higher in women than in men (P < 0.0001). The proportions of segments with attenuation of at least 300 HU in $ G_{30} $, $ G_{40} $, $ G_{50} $, $ G_{60} $ and $ G_{70} $ were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. Conclusions In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. Key Points • High-pitch dual-source coronary angiography is feasible with low contrast media volumes. • Traditional injection rules still apply: higher volumes result in higher enhancement. • The patient’s gender is a co-factor determining the level of contrast enhancement. • Volumes can be reduced down to 30–40 mL in selected patients..
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2013 |
---|---|
Erschienen: |
2013 |
Enthalten in: |
Zur Gesamtaufnahme - volume:24 |
---|---|
Enthalten in: |
European radiology - 24(2013), 1 vom: 15. Aug., Seite 120-127 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Lembcke, Alexander [VerfasserIn] |
---|
Links: |
Volltext [lizenzpflichtig] |
---|
Themen: |
Cardiac-gated imaging techniques |
---|
RVK: |
---|
Anmerkungen: |
© European Society of Radiology 2013 |
---|
doi: |
10.1007/s00330-013-2988-6 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
OLC2092266888 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | OLC2092266888 | ||
003 | DE-627 | ||
005 | 20230331112755.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230331s2013 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00330-013-2988-6 |2 doi | |
035 | |a (DE-627)OLC2092266888 | ||
035 | |a (DE-He213)s00330-013-2988-6-e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q VZ |
084 | |a ELIB24 |q VZ |2 rvk | ||
100 | 1 | |a Lembcke, Alexander |e verfasserin |4 aut | |
245 | 1 | 0 | |a High-pitch dual-source CT coronary angiography with low volumes of contrast medium |
264 | 1 | |c 2013 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a © European Society of Radiology 2013 | ||
520 | |a Objectives To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). Methods One-hundred consecutive patients (body weight 65–85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/$ m^{2} $) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes ($ G_{30} $, 30 mL; $ G_{40} $, 40 mL; $ G_{50} $, 50 mL; $ G_{60} $, 60 mL; $ G_{70} $, 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Results Mean attenuation for men and women ranged from 345.0 and 399.1 HU in $ G_{30} $ to 478.2 and 571.8 HU in $ G_{70} $. Mean attenuation values were higher in groups with higher CM volumes (P < 0.0001) and higher in women than in men (P < 0.0001). The proportions of segments with attenuation of at least 300 HU in $ G_{30} $, $ G_{40} $, $ G_{50} $, $ G_{60} $ and $ G_{70} $ were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. Conclusions In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. Key Points • High-pitch dual-source coronary angiography is feasible with low contrast media volumes. • Traditional injection rules still apply: higher volumes result in higher enhancement. • The patient’s gender is a co-factor determining the level of contrast enhancement. • Volumes can be reduced down to 30–40 mL in selected patients. | ||
650 | 4 | |a Cardiac-gated imaging techniques | |
650 | 4 | |a Contrast media | |
650 | 4 | |a Coronary angiography | |
650 | 4 | |a Coronary artery disease | |
650 | 4 | |a Multidetector computed tomography | |
700 | 1 | |a Schwenke, Carsten |4 aut | |
700 | 1 | |a Hein, Patrick A. |4 aut | |
700 | 1 | |a Knobloch, Gesine |4 aut | |
700 | 1 | |a Durmus, Tahir |4 aut | |
700 | 1 | |a Hamm, Bernd |4 aut | |
700 | 1 | |a Huppertz, Alexander |4 aut | |
773 | 0 | 8 | |i Enthalten in |t European radiology |d Springer Berlin Heidelberg, 1991 |g 24(2013), 1 vom: 15. Aug., Seite 120-127 |h Online-Ressource |w (DE-627)268757526 |w (DE-600)1472718-3 |w (DE-576)103868070 |x 1432-1084 |7 nnns |
773 | 1 | 8 | |g volume:24 |g year:2013 |g number:1 |g day:15 |g month:08 |g pages:120-127 |
856 | 4 | 0 | |u https://dx.doi.org/10.1007/s00330-013-2988-6 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a GBV_ILN_11 | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_101 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_120 | ||
912 | |a GBV_ILN_138 | ||
912 | |a GBV_ILN_150 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_152 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_187 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_267 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_636 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_711 | ||
912 | |a GBV_ILN_2001 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2004 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2007 | ||
912 | |a GBV_ILN_2008 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2010 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2026 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2031 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2037 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2039 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2049 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2057 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2070 | ||
912 | |a GBV_ILN_2086 | ||
912 | |a GBV_ILN_2088 | ||
912 | |a GBV_ILN_2093 | ||
912 | |a GBV_ILN_2106 | ||
912 | |a GBV_ILN_2107 | ||
912 | |a GBV_ILN_2108 | ||
912 | |a GBV_ILN_2110 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2112 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2116 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2119 | ||
912 | |a GBV_ILN_2122 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2144 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2148 | ||
912 | |a GBV_ILN_2152 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2188 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2232 | ||
912 | |a GBV_ILN_2336 | ||
912 | |a GBV_ILN_2446 | ||
912 | |a GBV_ILN_2470 | ||
912 | |a GBV_ILN_2474 | ||
912 | |a GBV_ILN_2507 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_2548 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4046 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4246 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4251 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4326 | ||
912 | |a GBV_ILN_4328 | ||
912 | |a GBV_ILN_4333 | ||
912 | |a GBV_ILN_4334 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4336 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4393 | ||
912 | |a GBV_ILN_4700 | ||
936 | r | v | |a ELIB24 |
951 | |a AR | ||
952 | |d 24 |j 2013 |e 1 |b 15 |c 08 |h 120-127 |