Efficacy and safety of novel temperature-controlled radiofrequency ablation system during pulmonary vein isolation in patients with paroxysmal atrial fibrillation: TRAC-AF study

Background and purpose Saline-irrigated radiofrequency ablation (RFA) for atrial fibrillation (AF) is limited by the absence of reliable thermal feedback limiting the utility of temperature monitoring for power titration. The DiamondTemp (DT) ablation catheter was designed to allow efficient temperature-controlled irrigated ablation. We sought to assess the 1-year clinical safety and efficacy of the DT catheter in treating drug-refractory paroxysmal AF. Methods The TRAC-AF trial (NCT02821351) is a prospective, multi-center (n = 4), single-arm study which enrolled patients with symptomatic, drug-refractory, paroxysmal AF. Using the DT catheter, point-by-point ablation was performed around all pulmonary veins (PVs) to achieve PV isolation (PVI). Ablation was performed in a temperature-controlled mode (60 °C, max 50 W). Acute and chronic efficacy and safety was evaluated. Results Seventy-one patients (age 69.9 ± 11.0 years; 60.6% male) were ablated using the DT catheter. The mean fluoroscopy and RF ablation times were 9.3 ± 6.1 min and 20.6 ± 8.9 min, respectively. Acute isolation of all PVs was achieved in 100% of patients, and freedom from AF after 1 year was 70.6%. There were no steam pops, char, or coagulum on the catheter tip after ablation. There were few serious procedure/device-related adverse events including a single case of cardiac tamponade (1.4%) and transient ischemic attack (1.4). Conclusion This first in man series demonstrates that temperature-controlled irrigated RFA with the DT catheter is efficient, safe, and effective in the treatment of paroxysmal AF. Randomized controlled trials are ongoing and will evaluate better the role of this catheter in relation to standard RFA. Trial registration Registered on the site ClinicalTrials.gov January 2016 with identifier: NCT02821351.

Medienart:

Artikel

Erscheinungsjahr:

2021

Erschienen:

2021

Enthalten in:

Zur Gesamtaufnahme - volume:64

Enthalten in:

Journal of interventional cardiac electrophysiology - 64(2021), 2 vom: 05. Juni, Seite 375-381

Sprache:

Englisch

Beteiligte Personen:

Starek, Zdenek [VerfasserIn]
Lehar, Frantisek [VerfasserIn]
Jez, Jiri [VerfasserIn]
Pesl, Martin [VerfasserIn]
Neuzil, Petr [VerfasserIn]
Sediva, Lucie [VerfasserIn]
Petru, Jan [VerfasserIn]
Dujka, Libor [VerfasserIn]
Funasako, Moritoshi [VerfasserIn]
Kautzner, Josef [VerfasserIn]
Peichl, Petr [VerfasserIn]
Aldhoon, Bashar [VerfasserIn]
Albenque, Jean-Paul [VerfasserIn]
Combes, Stephane [VerfasserIn]
Boveda, Serge [VerfasserIn]
Dukkipati, Srinivas R. [VerfasserIn]
Reddy, Vivek Y. [VerfasserIn]

Links:

Volltext [lizenzpflichtig]

Themen:

Atrial fibrillation
Catheter radiofrequency ablation
Diamond tip irrigated catheter
High-resolution electrograms
Safety and efficacy
Temperature contol ablation

Anmerkungen:

© Springer Science+Business Media, LLC, part of Springer Nature 2021

doi:

10.1007/s10840-021-00986-0

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

OLC2079402048