Topological Features of Electroencephalography are Robust to Re-referencing and Preprocessing
Abstract Electroencephalography (EEG) is among the most widely diffused, inexpensive, and adopted neuroimaging techniques. Nonetheless, EEG requires measurements against a reference site(s), which is typically chosen by the experimenter, and specific pre-processing steps precede analyses. It is therefore valuable to obtain quantities that are minimally affected by reference and pre-processing choices. Here, we show that the topological structure of embedding spaces, constructed either from multi-channel EEG timeseries or from their temporal structure, are subject-specific and robust to re-referencing and pre-processing pipelines. By contrast, the shape of correlation spaces, that is, discrete spaces where each point represents an electrode and the distance between them that is in turn related to the correlation between the respective timeseries, was neither significantly subject-specific nor robust to changes of reference. Our results suggest that the shape of spaces describing the observed configurations of EEG signals holds information about the individual specificity of the underlying individual’s brain dynamics, and that temporal correlations constrain to a large degree the set of possible dynamics. In turn, these encode the differences between subjects’ space of resting state EEG signals. Finally, our results and proposed methodology provide tools to explore the individual topographical landscapes and how they are explored dynamically. We propose therefore to augment conventional topographic analyses with an additional—topological—level of analysis, and to consider them jointly. More generally, these results provide a roadmap for the incorporation of topological analyses within EEG pipelines..
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2022 |
---|---|
Erschienen: |
2022 |
Enthalten in: |
Zur Gesamtaufnahme - volume:35 |
---|---|
Enthalten in: |
Brain topography - 35(2022), 1 vom: Jan., Seite 79-95 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Billings, Jacob [VerfasserIn] |
---|
Links: |
Volltext [lizenzpflichtig] |
---|
BKL: | |
---|---|
Themen: |
Computational modelling |
Anmerkungen: |
© The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 |
---|
doi: |
10.1007/s10548-021-00882-w |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
OLC2077957816 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2077957816 | ||
003 | DE-627 | ||
005 | 20230509110744.0 | ||
007 | tu | ||
008 | 221220s2022 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1007/s10548-021-00882-w |2 doi | |
035 | |a (DE-627)OLC2077957816 | ||
035 | |a (DE-He213)s10548-021-00882-w-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q VZ |
084 | |a 44.00 |2 bkl | ||
100 | 1 | |a Billings, Jacob |e verfasserin |0 (orcid)0000-0002-8186-6126 |4 aut | |
245 | 1 | 0 | |a Topological Features of Electroencephalography are Robust to Re-referencing and Preprocessing |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature 2021 | ||
520 | |a Abstract Electroencephalography (EEG) is among the most widely diffused, inexpensive, and adopted neuroimaging techniques. Nonetheless, EEG requires measurements against a reference site(s), which is typically chosen by the experimenter, and specific pre-processing steps precede analyses. It is therefore valuable to obtain quantities that are minimally affected by reference and pre-processing choices. Here, we show that the topological structure of embedding spaces, constructed either from multi-channel EEG timeseries or from their temporal structure, are subject-specific and robust to re-referencing and pre-processing pipelines. By contrast, the shape of correlation spaces, that is, discrete spaces where each point represents an electrode and the distance between them that is in turn related to the correlation between the respective timeseries, was neither significantly subject-specific nor robust to changes of reference. Our results suggest that the shape of spaces describing the observed configurations of EEG signals holds information about the individual specificity of the underlying individual’s brain dynamics, and that temporal correlations constrain to a large degree the set of possible dynamics. In turn, these encode the differences between subjects’ space of resting state EEG signals. Finally, our results and proposed methodology provide tools to explore the individual topographical landscapes and how they are explored dynamically. We propose therefore to augment conventional topographic analyses with an additional—topological—level of analysis, and to consider them jointly. More generally, these results provide a roadmap for the incorporation of topological analyses within EEG pipelines. | ||
650 | 4 | |a Resting-state electroencephalography | |
650 | 4 | |a Topography | |
650 | 4 | |a Topology | |
650 | 4 | |a Network | |
650 | 4 | |a Computational modelling | |
650 | 4 | |a Reference electrode | |
700 | 1 | |a Tivadar, Ruxandra |0 (orcid)0000-0002-6680-2917 |4 aut | |
700 | 1 | |a Murray, Micah M. |0 (orcid)0000-0002-7821-117X |4 aut | |
700 | 1 | |a Franceschiello, Benedetta |0 (orcid)0000-0003-0754-5081 |4 aut | |
700 | 1 | |a Petri, Giovanni |0 (orcid)0000-0003-1847-5031 |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Brain topography |d Springer US, 1988 |g 35(2022), 1 vom: Jan., Seite 79-95 |w (DE-627)170590720 |w (DE-600)1078442-1 |w (DE-576)063974428 |x 0896-0267 |7 nnns |
773 | 1 | 8 | |g volume:35 |g year:2022 |g number:1 |g month:01 |g pages:79-95 |
856 | 4 | 1 | |u https://doi.org/10.1007/s10548-021-00882-w |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-PHA | ||
912 | |a SSG-OLC-DE-84 | ||
936 | b | k | |a 44.00 |q VZ |
951 | |a AR | ||
952 | |d 35 |j 2022 |e 1 |c 01 |h 79-95 |