Determination of the standard deviation for proficiency assessment from past participant’s performances
Abstract The “uncertainty function” introduced by Thompson et al. estimates the reproducibility standard deviation as a function of concentration or mass fraction. This model was successfully applied to data derived from three proficiency testing schemes aiming at the quantification of cadmium, lead and mercury in blood and urine. This model allows the estimation of standard deviation for the performance assessment for proficiency testing rounds..
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2012 |
---|---|
Erschienen: |
2012 |
Enthalten in: |
Zur Gesamtaufnahme - volume:17 |
---|---|
Enthalten in: |
Accreditation and quality assurance - 17(2012), 4 vom: 19. Juni, Seite 389-393 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Côté, Isabelle [VerfasserIn] |
---|
Links: |
Volltext [lizenzpflichtig] |
---|
Themen: |
Horwitz equation |
---|
Anmerkungen: |
© The Author(s) 2012 |
---|
doi: |
10.1007/s00769-012-0906-2 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
OLC2051610878 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2051610878 | ||
003 | DE-627 | ||
005 | 20230502151022.0 | ||
007 | tu | ||
008 | 200819s2012 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1007/s00769-012-0906-2 |2 doi | |
035 | |a (DE-627)OLC2051610878 | ||
035 | |a (DE-He213)s00769-012-0906-2-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 540 |a 660 |q VZ |
100 | 1 | |a Côté, Isabelle |e verfasserin |4 aut | |
245 | 1 | 0 | |a Determination of the standard deviation for proficiency assessment from past participant’s performances |
264 | 1 | |c 2012 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © The Author(s) 2012 | ||
520 | |a Abstract The “uncertainty function” introduced by Thompson et al. estimates the reproducibility standard deviation as a function of concentration or mass fraction. This model was successfully applied to data derived from three proficiency testing schemes aiming at the quantification of cadmium, lead and mercury in blood and urine. This model allows the estimation of standard deviation for the performance assessment for proficiency testing rounds. | ||
650 | 4 | |a Horwitz equation | |
650 | 4 | |a Thompson-modified equation | |
650 | 4 | |a Uncertainty function | |
650 | 4 | |a Limit of detection | |
650 | 4 | |a Reproducibility | |
650 | 4 | |a Proficiency testing | |
700 | 1 | |a Robouch, Piotr |4 aut | |
700 | 1 | |a Robouch, Benjamin |4 aut | |
700 | 1 | |a Bisson, David |4 aut | |
700 | 1 | |a Gamache, Philippe |4 aut | |
700 | 1 | |a LeBlanc, Alain |4 aut | |
700 | 1 | |a Dumas, Pierre |4 aut | |
700 | 1 | |a Pedneault, Mikaël |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Accreditation and quality assurance |d Springer-Verlag, 1996 |g 17(2012), 4 vom: 19. Juni, Seite 389-393 |w (DE-627)198683790 |w (DE-600)1315843-0 |w (DE-576)052818772 |x 0949-1775 |7 nnns |
773 | 1 | 8 | |g volume:17 |g year:2012 |g number:4 |g day:19 |g month:06 |g pages:389-393 |
856 | 4 | 1 | |u https://doi.org/10.1007/s00769-012-0906-2 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_267 | ||
912 | |a GBV_ILN_2016 | ||
912 | |a GBV_ILN_2018 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4277 | ||
951 | |a AR | ||
952 | |d 17 |j 2012 |e 4 |b 19 |c 06 |h 389-393 |