Production, quality control of next-generation PET radioisotope iodine-124 and its thyroid imaging
Abstract In this paper, 124Te(p,n)124I nuclear reaction was used for 124I production. The 124$ TeO_{2} $/$ Al_{2} $$ O_{3} $ target was irradiated by 12.5 MeV proton at 20 μA for 3–8 h in a medical cyclotron. After irradiation, 124I was purified by dry distillation and dissolved in 0.02 M NaOH, with radioactivity 370–1480 MBq. Micro-PET/CT imaging of 124I in healthy mice showed the thyroid and stomach accumulations and kidney metabolism, which may be useful for thyroid disease diagnosis. In summary, we have produced next-generation PET radioisotope 124I routinely in sufficient and high quality..
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2018 |
---|---|
Erschienen: |
2018 |
Enthalten in: |
Zur Gesamtaufnahme - volume:318 |
---|---|
Enthalten in: |
Journal of radioanalytical and nuclear chemistry - 318(2018), 3 vom: 27. Okt., Seite 1999-2006 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Wang, Feng [VerfasserIn] |
---|
Links: |
Volltext [lizenzpflichtig] |
---|
BKL: | |
---|---|
Themen: |
Iodine-124 |
Anmerkungen: |
© Akadémiai Kiadó, Budapest, Hungary 2018 |
---|
doi: |
10.1007/s10967-018-6277-3 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
OLC2041978147 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2041978147 | ||
003 | DE-627 | ||
005 | 20230518142151.0 | ||
007 | tu | ||
008 | 200819s2018 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1007/s10967-018-6277-3 |2 doi | |
035 | |a (DE-627)OLC2041978147 | ||
035 | |a (DE-He213)s10967-018-6277-3-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 540 |q VZ |
084 | |a 35.00 |2 bkl | ||
100 | 1 | |a Wang, Feng |e verfasserin |4 aut | |
245 | 1 | 0 | |a Production, quality control of next-generation PET radioisotope iodine-124 and its thyroid imaging |
264 | 1 | |c 2018 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © Akadémiai Kiadó, Budapest, Hungary 2018 | ||
520 | |a Abstract In this paper, 124Te(p,n)124I nuclear reaction was used for 124I production. The 124$ TeO_{2} $/$ Al_{2} $$ O_{3} $ target was irradiated by 12.5 MeV proton at 20 μA for 3–8 h in a medical cyclotron. After irradiation, 124I was purified by dry distillation and dissolved in 0.02 M NaOH, with radioactivity 370–1480 MBq. Micro-PET/CT imaging of 124I in healthy mice showed the thyroid and stomach accumulations and kidney metabolism, which may be useful for thyroid disease diagnosis. In summary, we have produced next-generation PET radioisotope 124I routinely in sufficient and high quality. | ||
650 | 4 | |a Solid target | |
650 | 4 | |a Iodine-124 | |
650 | 4 | |a Positron emission tomography (PET) | |
650 | 4 | |a Thyroid imaging | |
700 | 1 | |a Liu, Teli |4 aut | |
700 | 1 | |a Li, Liqiang |4 aut | |
700 | 1 | |a Guo, Xiaoyi |4 aut | |
700 | 1 | |a Duan, Dongban |4 aut | |
700 | 1 | |a Liu, Zhibo |4 aut | |
700 | 1 | |a Zhu, Hua |4 aut | |
700 | 1 | |a Yang, Zhi |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of radioanalytical and nuclear chemistry |d Springer International Publishing, 1984 |g 318(2018), 3 vom: 27. Okt., Seite 1999-2006 |w (DE-627)129942642 |w (DE-600)392456-7 |w (DE-576)015507769 |x 0236-5731 |7 nnns |
773 | 1 | 8 | |g volume:318 |g year:2018 |g number:3 |g day:27 |g month:10 |g pages:1999-2006 |
856 | 4 | 1 | |u https://doi.org/10.1007/s10967-018-6277-3 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-CHE | ||
912 | |a SSG-OLC-PHA | ||
912 | |a SSG-OLC-DE-84 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_4012 | ||
936 | b | k | |a 35.00 |q VZ |
951 | |a AR | ||
952 | |d 318 |j 2018 |e 3 |b 27 |c 10 |h 1999-2006 |