The upgrading of the cyclic neutron activation analysis facility at the Dalat research reactor

Abstract The cyclic neutron activation analysis (CNAA) facility based on a pneumatic transfer system for short irradiation and rapid counting has recently been upgraded at the Dalat research reactor. The original facility was only designed for single irradiation. Therefore, this work has aimed to upgrade both hardware and software for the cyclic irradiation. In this paper, the upgrading of the facility for CNAA was described. Irradiation time of the facility were calibrated, thereby reducing irradiation time to seconds with precision. The accuracy and sensitivity of CNAA based-on the upgraded facility were assessed by determination of some short-lived nuclides..

Medienart:

Artikel

Erscheinungsjahr:

2017

Erschienen:

2017

Enthalten in:

Zur Gesamtaufnahme - volume:315

Enthalten in:

Journal of radioanalytical and nuclear chemistry - 315(2017), 3 vom: 29. Dez., Seite 703-709

Sprache:

Englisch

Beteiligte Personen:

Ho, Van Doanh [VerfasserIn]
Ho, Manh Dung [VerfasserIn]
Ha, Thanh Viet [VerfasserIn]
Tran, Quang Thien [VerfasserIn]
Cao, Dong Vu [VerfasserIn]

Links:

Volltext [lizenzpflichtig]

BKL:

35.00

Themen:

Cyclic neutron activation analysis
Dalat research reactor
K0-CNAA

Anmerkungen:

© Akadémiai Kiadó, Budapest, Hungary 2017

doi:

10.1007/s10967-017-5673-4

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

OLC2041973072