A New Bioreactor for the Development of Tissue-Engineered Heart Valves
Abstract This paper reports the design, manufacturing, and characterization of a new bioreactor dedicated to the development of tissue-engineered heart valve substitutes. First, a comprehensive review of the state of the art in bioreactors is presented and a rigorous classification is put forward. The existing bioreactors found in literature are organized in three groups and discussed with respect to their quality of reproduction compared to the physiological environment. The bioreactor architecture is then decomposed into basic components which may be grouped together in different arrangements, and the well-known Windkessel approach is used to study the global behavior of the system. Then, the new design, which is based on a synthesis of the features of the most evolved systems as well as on new improvements, is explained in detail. Optimal fluid dynamics are obtained with the presented bioreactor through carefully designed components and an advanced computer-controlled actuator. This allows a very accurate reproduction of physiological parameters, namely the pulsating flow rate and pressure. Finally, experimental results of flow rate and pressure waveforms are presented, where an excellent correlation with physiological measurements can be observed..
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2009 |
---|---|
Erschienen: |
2009 |
Enthalten in: |
Zur Gesamtaufnahme - volume:37 |
---|---|
Enthalten in: |
Annals of biomedical engineering - 37(2009), 4 vom: 23. Jan., Seite 674-681 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Ruel, Jean [VerfasserIn] |
---|
Links: |
Volltext [lizenzpflichtig] |
---|
Themen: |
---|
Anmerkungen: |
© Biomedical Engineering Society 2009 |
---|
doi: |
10.1007/s10439-009-9646-9 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
OLC2036406157 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2036406157 | ||
003 | DE-627 | ||
005 | 20230502193202.0 | ||
007 | tu | ||
008 | 200820s2009 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1007/s10439-009-9646-9 |2 doi | |
035 | |a (DE-627)OLC2036406157 | ||
035 | |a (DE-He213)s10439-009-9646-9-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q VZ |
100 | 1 | |a Ruel, Jean |e verfasserin |4 aut | |
245 | 1 | 0 | |a A New Bioreactor for the Development of Tissue-Engineered Heart Valves |
264 | 1 | |c 2009 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © Biomedical Engineering Society 2009 | ||
520 | |a Abstract This paper reports the design, manufacturing, and characterization of a new bioreactor dedicated to the development of tissue-engineered heart valve substitutes. First, a comprehensive review of the state of the art in bioreactors is presented and a rigorous classification is put forward. The existing bioreactors found in literature are organized in three groups and discussed with respect to their quality of reproduction compared to the physiological environment. The bioreactor architecture is then decomposed into basic components which may be grouped together in different arrangements, and the well-known Windkessel approach is used to study the global behavior of the system. Then, the new design, which is based on a synthesis of the features of the most evolved systems as well as on new improvements, is explained in detail. Optimal fluid dynamics are obtained with the presented bioreactor through carefully designed components and an advanced computer-controlled actuator. This allows a very accurate reproduction of physiological parameters, namely the pulsating flow rate and pressure. Finally, experimental results of flow rate and pressure waveforms are presented, where an excellent correlation with physiological measurements can be observed. | ||
650 | 4 | |a Bioreactor | |
650 | 4 | |a Design | |
650 | 4 | |a Heart valve | |
650 | 4 | |a Tissue engineering | |
650 | 4 | |a Windkessel | |
700 | 1 | |a Lachance, Geneviève |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Annals of biomedical engineering |d Springer US, 1972 |g 37(2009), 4 vom: 23. Jan., Seite 674-681 |w (DE-627)129397709 |w (DE-600)185984-5 |w (DE-576)014780984 |x 0090-6964 |7 nnns |
773 | 1 | 8 | |g volume:37 |g year:2009 |g number:4 |g day:23 |g month:01 |g pages:674-681 |
856 | 4 | 1 | |u https://doi.org/10.1007/s10439-009-9646-9 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_2016 | ||
912 | |a GBV_ILN_4012 | ||
951 | |a AR | ||
952 | |d 37 |j 2009 |e 4 |b 23 |c 01 |h 674-681 |