A Simple Extraction Procedure for HPLC Analysis of Fluoxetine in Rat Plasma Samples
In present study, a simple liquid-liquid extraction-high performance liquid chromatography-fluorescence method was developed for the determination of fluoxetine (FLU) in rat plasma samples. A MZ Analytical Column C18 (250 mm x 4.6 mm, 5µm i.d.) was used for the separation of FLU. The total analysis time was less than 7 minutes. The rat plasma samples were simply treated with acetonitrile and analyzed using developed method. The recovery of the FLU from rat plasma samples is 92.70% ± 0.48. FLU in spiked rat plasma samples provided linear data over a range of 0.2 - 2.00 µg mL-1. The method was validated according to the FDA guidelines and can be proposed for quantification of FLU in rat plasma..
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2017 |
---|---|
Erschienen: |
2017 |
Enthalten in: |
Zur Gesamtaufnahme - volume:13 |
---|---|
Enthalten in: |
Current pharmaceutical analysis - 13(2017), 1, Seite 80-84 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Recber, Tuba [VerfasserIn] |
---|
Links: |
---|
BKL: |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
OLC1986715981 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC1986715981 | ||
003 | DE-627 | ||
005 | 20230518181140.0 | ||
007 | cr uuu---uuuuu | ||
008 | 170131s2017 xx |||||o 00| ||eng c | ||
028 | 5 | 2 | |a fidpha_zeitschriften_20170130.pp |
035 | |a (DE-627)OLC1986715981 | ||
035 | |a (DE-599)GBVOLC1986715981 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |
084 | |a PHARM |2 fid | ||
084 | |a 44.40 |2 bkl | ||
100 | 1 | |a Recber, Tuba |e verfasserin |4 aut | |
245 | 1 | 0 | |a A Simple Extraction Procedure for HPLC Analysis of Fluoxetine in Rat Plasma Samples |
264 | 1 | |c 2017 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a In present study, a simple liquid-liquid extraction-high performance liquid chromatography-fluorescence method was developed for the determination of fluoxetine (FLU) in rat plasma samples. A MZ Analytical Column C18 (250 mm x 4.6 mm, 5µm i.d.) was used for the separation of FLU. The total analysis time was less than 7 minutes. The rat plasma samples were simply treated with acetonitrile and analyzed using developed method. The recovery of the FLU from rat plasma samples is 92.70% ± 0.48. FLU in spiked rat plasma samples provided linear data over a range of 0.2 - 2.00 µg mL-1. The method was validated according to the FDA guidelines and can be proposed for quantification of FLU in rat plasma. | ||
700 | 1 | |a Ozkan, Ece |e verfasserin |4 aut | |
700 | 1 | |a Eren-Kocak, Emine |e verfasserin |4 aut | |
700 | 1 | |a Y|lmaz, Murat |e verfasserin |4 aut | |
700 | 1 | |a Nemutlu, Emirhan |e verfasserin |4 aut | |
700 | 1 | |a K|r, Sedef |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Current pharmaceutical analysis |d Sharjah : Bentham Sc. Publ., 2005 |g 13(2017), 1, Seite 80-84 |w (DE-627)486563324 |w (DE-600)2188299-X |w (DE-576)435514342 |x 1573-4129 |7 nnns |
773 | 1 | 8 | |g volume:13 |g year:2017 |g number:1 |g pages:80-84 |
856 | 4 | 0 | |u http://www.eurekaselect.com/openurl/content.php?genre=article&issn=1573-4129&volume=13&issue=1&spage=80 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a FID-PHARM | ||
912 | |a SSG-OLC-PHA | ||
912 | |a SSG-OLC-DE-84 | ||
912 | |a SSG-OPC-PHA | ||
936 | b | k | |a 44.40 |q AVZ |
951 | |a AR | ||
952 | |d 13 |j 2017 |e 1 |h 80-84 |