Comparison of sensitivity and specificity of 4 methods for detection of Giardia duodenalis in feces: immunofluorescence and PCR are superior to microscopy of concentrated iodine-stained samples
For decades, microscopy of feces after formol-ethylacetate (FEA) concentration and iodine staining has been the routine test for intestinal protozoa. Lately, polymerase chain reaction or fluorescence-labeled parasite-specific antibodies have been introduced, but their place in everyday routine diagnostics has not yet been established. We compared FEA and salt-sugar flotation (SSF) concentration followed by microscopy of iodine-stained concentrate and immunofluorescence assay (IFA) and real-time polymerase chain reaction (qPCR) for detection of Giardia duodenalis in human feces. The median number of Giardia cysts found by FEA in 19 Giardia-positive samples was 50 cysts per gram (CPG), by SSF 350 CPG, by IFA 76,700 CPG, and by qPCR 316,000 CPG. We next tested 455 consecutive samples for presence of Giardia cysts. Using IFA as reference, qPCR had a sensitivity of 91%, specificity of 95.1%, a false-positive rate of 50%, a false-negative rate of 0.48%, a positive predictive value of 50%, and a negative predictive value of 99.5%. In conclusion, qPCR and IFA were significantly more sensitive than microscopy of iodine-stained concentrates using either FEA or SSF. We suggest, when using qPCR, that positive samples are verified by IFA to prevent false-positive results..
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2016 |
---|---|
Erschienen: |
2016 |
Enthalten in: |
Zur Gesamtaufnahme - volume:84 |
---|---|
Enthalten in: |
Diagnostic microbiology and infectious disease - 84(2016), 3, Seite 187 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Gotfred-Rasmussen, Helle [VerfasserIn] |
---|
Links: |
---|
BKL: |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
OLC1973036894 |
---|
LEADER | 01000caa a2200265 4500 | ||
---|---|---|---|
001 | OLC1973036894 | ||
003 | DE-627 | ||
005 | 20220217023510.0 | ||
007 | tu | ||
008 | 160427s2016 xx ||||| 00| ||eng c | ||
028 | 5 | 2 | |a PQ20160430 |
035 | |a (DE-627)OLC1973036894 | ||
035 | |a (DE-599)GBVOLC1973036894 | ||
035 | |a (PRQ)p1123-f50518e9a39ae2b90930d294d3263f72fc4ac45454a438a391480c49f9e9eefe0 | ||
035 | |a (KEY)0121288520160000084000300187comparisonofsensitivityandspecificityof4methodsfor | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q DE-600 |
084 | |a 44.00 |2 bkl | ||
100 | 1 | |a Gotfred-Rasmussen, Helle |e verfasserin |4 aut | |
245 | 1 | 0 | |a Comparison of sensitivity and specificity of 4 methods for detection of Giardia duodenalis in feces: immunofluorescence and PCR are superior to microscopy of concentrated iodine-stained samples |
264 | 1 | |c 2016 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
520 | |a For decades, microscopy of feces after formol-ethylacetate (FEA) concentration and iodine staining has been the routine test for intestinal protozoa. Lately, polymerase chain reaction or fluorescence-labeled parasite-specific antibodies have been introduced, but their place in everyday routine diagnostics has not yet been established. We compared FEA and salt-sugar flotation (SSF) concentration followed by microscopy of iodine-stained concentrate and immunofluorescence assay (IFA) and real-time polymerase chain reaction (qPCR) for detection of Giardia duodenalis in human feces. The median number of Giardia cysts found by FEA in 19 Giardia-positive samples was 50 cysts per gram (CPG), by SSF 350 CPG, by IFA 76,700 CPG, and by qPCR 316,000 CPG. We next tested 455 consecutive samples for presence of Giardia cysts. Using IFA as reference, qPCR had a sensitivity of 91%, specificity of 95.1%, a false-positive rate of 50%, a false-negative rate of 0.48%, a positive predictive value of 50%, and a negative predictive value of 99.5%. In conclusion, qPCR and IFA were significantly more sensitive than microscopy of iodine-stained concentrates using either FEA or SSF. We suggest, when using qPCR, that positive samples are verified by IFA to prevent false-positive results. | ||
540 | |a Nutzungsrecht: Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved. | ||
700 | 1 | |a Lund, Marianne |4 oth | |
700 | 1 | |a Enemark, Heidi L |4 oth | |
700 | 1 | |a Erlandsen, Mogens |4 oth | |
700 | 1 | |a Petersen, Eskild |4 oth | |
773 | 0 | 8 | |i Enthalten in |t Diagnostic microbiology and infectious disease |d New York, NY : Elsevier, 1983 |g 84(2016), 3, Seite 187 |w (DE-627)130399507 |w (DE-600)604920-5 |w (DE-576)025082213 |x 0732-8893 |7 nnns |
773 | 1 | 8 | |g volume:84 |g year:2016 |g number:3 |g pages:187 |
856 | 4 | 2 | |u http://www.ncbi.nlm.nih.gov/pubmed/26707069 |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4219 | ||
936 | b | k | |a 44.00 |q AVZ |
951 | |a AR | ||
952 | |d 84 |j 2016 |e 3 |h 187 |