Effect of Transcranial Direct Current Stimulation over the Primary Motor Cortex on Cerebral Blood Flow: A Time Course Study Using Near-infrared Spectroscopy
Transcranial direct current stimulation (tDCS) is a noninvasive brain stimulation technique that is applied during stroke rehabilitation. The purpose of this study was to examine diachronic intracranial hemodynamic changes using near-infrared spectroscopy (NIRS) during tDCS applied to the primary motor cortex (M1). Seven healthy volunteers were tested during real stimulation (anodal and cathodal) and during sham stimulation. Stimulation lasted 20 min and NIRS data were collected for about 23 min including the baseline. NIRS probe holders were positioned over the entire contralateral sensory motor area. Compared to the sham condition, both anodal and cathodal stimulation resulted in significantly lower oxyhemoglobin (O2Hb) concentrations in the contralateral premotor cortex (PMC), supplementary motor area (SMA), and M1 (p < 0.01). Particularly in the SMA, the O2Hb concentration during anodal stimulation was significantly lower than that during the sham condition (p < 0.01), while the O2Hb concentration during cathodal stimulation was lower than that during anodal stimulation (p < 0.01). In addition, in the primary sensory cortex, the O2Hb concentration during anodal stimulation was significantly higher than the concentrations during both cathodal stimulation and the sham condition (p < 0.05). The factor of time did not demonstrate significant differences. These results suggest that both anodal and cathodal tDCS cause widespread changes in cerebral blood flow, not only in the area immediately under the electrode, but also in other areas of the cortex..
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2016 |
---|---|
Erschienen: |
2016 |
Enthalten in: |
Zur Gesamtaufnahme - volume:876 |
---|---|
Enthalten in: |
Advances in experimental medicine and biology - 876(2016), Seite 335 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Takai, Haruna [VerfasserIn] |
---|
Links: |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
OLC1970566590 |
---|
LEADER | 01000caa a2200265 4500 | ||
---|---|---|---|
001 | OLC1970566590 | ||
003 | DE-627 | ||
005 | 20230511233930.0 | ||
007 | tu | ||
008 | 160212s2016 xx ||||| 00| ||eng c | ||
028 | 5 | 2 | |a PQ20160212 |
035 | |a (DE-627)OLC1970566590 | ||
035 | |a (DE-599)GBVOLC1970566590 | ||
035 | |a (PRQ)pubmed_primary_267822300 | ||
035 | |a (KEY)0028055020160000876000000335effectoftranscranialdirectcurrentstimulationoverth | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 050 |q DNB |
082 | 0 | 4 | |a 610 |q AVZ |
100 | 1 | |a Takai, Haruna |e verfasserin |4 aut | |
245 | 1 | 0 | |a Effect of Transcranial Direct Current Stimulation over the Primary Motor Cortex on Cerebral Blood Flow: A Time Course Study Using Near-infrared Spectroscopy |
264 | 1 | |c 2016 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
520 | |a Transcranial direct current stimulation (tDCS) is a noninvasive brain stimulation technique that is applied during stroke rehabilitation. The purpose of this study was to examine diachronic intracranial hemodynamic changes using near-infrared spectroscopy (NIRS) during tDCS applied to the primary motor cortex (M1). Seven healthy volunteers were tested during real stimulation (anodal and cathodal) and during sham stimulation. Stimulation lasted 20 min and NIRS data were collected for about 23 min including the baseline. NIRS probe holders were positioned over the entire contralateral sensory motor area. Compared to the sham condition, both anodal and cathodal stimulation resulted in significantly lower oxyhemoglobin (O2Hb) concentrations in the contralateral premotor cortex (PMC), supplementary motor area (SMA), and M1 (p < 0.01). Particularly in the SMA, the O2Hb concentration during anodal stimulation was significantly lower than that during the sham condition (p < 0.01), while the O2Hb concentration during cathodal stimulation was lower than that during anodal stimulation (p < 0.01). In addition, in the primary sensory cortex, the O2Hb concentration during anodal stimulation was significantly higher than the concentrations during both cathodal stimulation and the sham condition (p < 0.05). The factor of time did not demonstrate significant differences. These results suggest that both anodal and cathodal tDCS cause widespread changes in cerebral blood flow, not only in the area immediately under the electrode, but also in other areas of the cortex. | ||
700 | 1 | |a Sugawara, Kazuhiro |4 oth | |
700 | 1 | |a Onishi, Hideaki |4 oth | |
700 | 1 | |a Oyanagi, Keiichi |4 oth | |
700 | 1 | |a Miyaguchi, Shota |4 oth | |
700 | 1 | |a Matsumoto, Takuya |4 oth | |
700 | 1 | |a Yamamoto, Noriaki |4 oth | |
700 | 1 | |a Tsubaki, Atsuhiro |4 oth | |
773 | 0 | 8 | |i Enthalten in |t Advances in experimental medicine and biology |d Cham : Springer, 1967 |g 876(2016), Seite 335 |w (DE-627)129970778 |w (DE-600)410187-X |w (DE-576)015534642 |x 0065-2598 |
773 | 1 | 8 | |g volume:876 |g year:2016 |g pages:335 |
856 | 4 | 2 | |u http://www.ncbi.nlm.nih.gov/pubmed/26782230 |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-PHA | ||
912 | |a SSG-OLC-DE-84 | ||
912 | |a GBV_ILN_4219 | ||
951 | |a AR | ||
952 | |d 876 |j 2016 |h 335 |