Laboratory errors – why the laboratory is not (always) to blame
More than half of the so called "laboratory errors" has already happened before the analysis starts in the laboratory and many mistakes are made after the analysis itself. Pre- and post-analytical errors cause 60 to 90 % of all unexpected or erroneous values; only 10 to 15 % are caused by analytical problems. Internal quality control and external quality assessments are a matter of course today while standardisation still could be improved. The pre- and post-analytical processes however are only scarcely supervised. Good patient preparation, reliable patient identification and correct blood draws still cannot be taken for granted - improved training and education are necessary. There is also room for improvement in the communication of the results and the implementation of the consequences thereof. Errors in all phases of the analytical process contain valuable clues for optimisations. An improved culture of failure management would allow tapping the full potential of these clues..
Medienart: |
Artikel |
---|
Erscheinungsjahr: |
2015 |
---|---|
Erschienen: |
2015 |
Enthalten in: |
Zur Gesamtaufnahme - volume:72 |
---|---|
Enthalten in: |
Therapeutische Umschau - 72(2015), 2, Seite 113 |
Sprache: |
Deutsch |
---|
Beteiligte Personen: |
Savoca, Reto [VerfasserIn] |
---|
Links: |
---|
Förderinstitution / Projekttitel: |
|
---|
PPN (Katalog-ID): |
OLC1965588492 |
---|
LEADER | 01000caa a2200265 4500 | ||
---|---|---|---|
001 | OLC1965588492 | ||
003 | DE-627 | ||
005 | 20210716025946.0 | ||
007 | tu | ||
008 | 160206s2015 xx ||||| 00| ||ger c | ||
028 | 5 | 2 | |a PQ20160617 |
035 | |a (DE-627)OLC1965588492 | ||
035 | |a (DE-599)GBVOLC1965588492 | ||
035 | |a (PRQ)pubmed_primary_256302930 | ||
035 | |a (KEY)0046632820150000072000200113laboratoryerrorswhythelaboratoryisnotalwaystoblame | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a ger | ||
082 | 0 | 4 | |a 610 |q DNB |
100 | 1 | |a Savoca, Reto |e verfasserin |4 aut | |
245 | 1 | 0 | |a Laboratory errors – why the laboratory is not (always) to blame |
264 | 1 | |c 2015 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
520 | |a More than half of the so called "laboratory errors" has already happened before the analysis starts in the laboratory and many mistakes are made after the analysis itself. Pre- and post-analytical errors cause 60 to 90 % of all unexpected or erroneous values; only 10 to 15 % are caused by analytical problems. Internal quality control and external quality assessments are a matter of course today while standardisation still could be improved. The pre- and post-analytical processes however are only scarcely supervised. Good patient preparation, reliable patient identification and correct blood draws still cannot be taken for granted - improved training and education are necessary. There is also room for improvement in the communication of the results and the implementation of the consequences thereof. Errors in all phases of the analytical process contain valuable clues for optimisations. An improved culture of failure management would allow tapping the full potential of these clues. | ||
650 | 4 | |a Diagnostic Errors - statistics & numerical data | |
650 | 4 | |a Clinical Laboratory Services - statistics & numerical data | |
650 | 4 | |a Diagnostic Tests, Routine - statistics & numerical data | |
650 | 4 | |a Clinical Laboratory Techniques - statistics & numerical data | |
650 | 4 | |a Diagnostic Errors - prevention & control | |
773 | 0 | 8 | |i Enthalten in |t Therapeutische Umschau |d Bern : Hogrefe, 1960 |g 72(2015), 2, Seite 113 |w (DE-627)129271403 |w (DE-600)82044-1 |w (DE-576)014462117 |x 0040-5930 |7 nnns |
773 | 1 | 8 | |g volume:72 |g year:2015 |g number:2 |g pages:113 |
856 | 4 | 2 | |u http://www.ncbi.nlm.nih.gov/pubmed/25630293 |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-PSY | ||
912 | |a GBV_ILN_72 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_267 | ||
912 | |a GBV_ILN_287 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2008 | ||
912 | |a GBV_ILN_2012 | ||
912 | |a GBV_ILN_2474 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4219 | ||
912 | |a GBV_ILN_4247 | ||
912 | |a GBV_ILN_4320 | ||
951 | |a AR | ||
952 | |d 72 |j 2015 |e 2 |h 113 |