Feasibility and efficacy of real-time ultrasound-guided venous closure with suture-mediated vascular closure device
Copyright © 2024 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved..
BACKGROUND: Venous vascular access complications are usually nonfatal but are the most common complications after transvenous catheter intervention. Vascular closure devices (VCDs) have recently become available for venous closure.
OBJECTIVE: This study aimed to evaluate the feasibility and efficacy of real-time ultrasound-guided venous closure with suture-mediated VCDs in patients who underwent catheter ablation.
METHODS: This single-center observational study enrolled 226 consecutive patients who underwent elective catheter ablation with femoral venipuncture. For hemostasis, vessel closure by VCD was performed with real-time ultrasound guidance after 2022 (n = 123) and without ultrasound guidance in 2021 (n = 103). The occurrence of venous access site-related complications (major, minor, or other) was compared.
RESULTS: The rate of device failure was significantly lower in patients with ultrasound guidance than in those without (1.6% vs 6.3%; P = .048). The occurrence of all venous access site-related complications was significantly lower in patients with ultrasound guidance than in those without (4.9% vs 18.4%; P = .001). Time to ambulation was shorter in patients with ultrasound guidance than in those without (2.0 ± 0.1 hours vs 2.2 ± 0.6 hours; P < .001).
CONCLUSION: Real-time ultrasound guidance can reduce device failure, access site-related complications, and time to ambulation in performing venous closure with a VCD.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - year:2024 |
---|---|
Enthalten in: |
Heart rhythm - (2024) vom: 10. Apr. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Tachi, Masaya [VerfasserIn] |
---|
Links: |
---|
Themen: |
Ablation |
---|
Anmerkungen: |
Date Revised 28.04.2024 published: Print-Electronic Citation Status Publisher |
---|
doi: |
10.1016/j.hrthm.2024.04.041 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM370982290 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM370982290 | ||
003 | DE-627 | ||
005 | 20240429232152.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240413s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.hrthm.2024.04.041 |2 doi | |
028 | 5 | 2 | |a pubmed24n1392.xml |
035 | |a (DE-627)NLM370982290 | ||
035 | |a (NLM)38608918 | ||
035 | |a (PII)S1547-5271(24)02368-3 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Tachi, Masaya |e verfasserin |4 aut | |
245 | 1 | 0 | |a Feasibility and efficacy of real-time ultrasound-guided venous closure with suture-mediated vascular closure device |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 28.04.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status Publisher | ||
520 | |a Copyright © 2024 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved. | ||
520 | |a BACKGROUND: Venous vascular access complications are usually nonfatal but are the most common complications after transvenous catheter intervention. Vascular closure devices (VCDs) have recently become available for venous closure | ||
520 | |a OBJECTIVE: This study aimed to evaluate the feasibility and efficacy of real-time ultrasound-guided venous closure with suture-mediated VCDs in patients who underwent catheter ablation | ||
520 | |a METHODS: This single-center observational study enrolled 226 consecutive patients who underwent elective catheter ablation with femoral venipuncture. For hemostasis, vessel closure by VCD was performed with real-time ultrasound guidance after 2022 (n = 123) and without ultrasound guidance in 2021 (n = 103). The occurrence of venous access site-related complications (major, minor, or other) was compared | ||
520 | |a RESULTS: The rate of device failure was significantly lower in patients with ultrasound guidance than in those without (1.6% vs 6.3%; P = .048). The occurrence of all venous access site-related complications was significantly lower in patients with ultrasound guidance than in those without (4.9% vs 18.4%; P = .001). Time to ambulation was shorter in patients with ultrasound guidance than in those without (2.0 ± 0.1 hours vs 2.2 ± 0.6 hours; P < .001) | ||
520 | |a CONCLUSION: Real-time ultrasound guidance can reduce device failure, access site-related complications, and time to ambulation in performing venous closure with a VCD | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Ablation | |
650 | 4 | |a Ultrasound guidance | |
650 | 4 | |a VCD | |
650 | 4 | |a Vascular closure device | |
650 | 4 | |a Venous closure | |
700 | 1 | |a Tanaka, Akihito |e verfasserin |4 aut | |
700 | 1 | |a Teraoka, Tsubasa |e verfasserin |4 aut | |
700 | 1 | |a Furuta, Tappei |e verfasserin |4 aut | |
700 | 1 | |a Matsushita, Etsushi |e verfasserin |4 aut | |
700 | 1 | |a Hayashi, Kazunori |e verfasserin |4 aut | |
700 | 1 | |a Shimojo, Masafumi |e verfasserin |4 aut | |
700 | 1 | |a Yanagisawa, Satoshi |e verfasserin |4 aut | |
700 | 1 | |a Inden, Yasuya |e verfasserin |4 aut | |
700 | 1 | |a Murohara, Toyoaki |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Heart rhythm |d 2004 |g (2024) vom: 10. Apr. |w (DE-627)NLM154896640 |x 1556-3871 |7 nnns |
773 | 1 | 8 | |g year:2024 |g day:10 |g month:04 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.hrthm.2024.04.041 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |j 2024 |b 10 |c 04 |