Torque-Cadence Profile and Maximal Dynamic Force in Cyclists : A Novel Approach
We aimed to determine the feasibility, test-retest reliability and long-term stability of a novel method for assessing the force (torque)-velocity (cadence) profile and maximal dynamic force (MDF) during leg-pedaling using a friction-loaded isoinertial cycle ergometer and a high-precision power-meter device. Fifty-two trained male cyclists completed a progressive loading test up to the one-repetition maximum (1RM) on a cycle ergometer. The MDF was defined as the force attained at the cycle performed with the 1RM-load. To examine the test-retest reliability and long-term stability of torque-cadence values, the progressive test was repeated after 72 h and also after 10 weeks of aerobic and strength training. The participants' MDF averaged 13.4 ± 1.3 N·kg-1, which was attained with an average pedal cadence of 21 ± 3 rpm. Participants' highest power output value was attained with a cadence of 110 ± 16 rpm (52 ± 5% MDF). The relationship between the MDF and cadence proved to be very strong (R2 = 0.978) and independent of the cyclists' MDF (p = 0.66). Cadence values derived from this relationship revealed a very high test-retest repeatability (mean SEM = 4 rpm, 3.3%) and long-term stability (SEM = 3 rpm, 2.3%); despite increases in the MDF following the 10-week period. Our findings support the validity, reliability and long-term stability of this method for the assessment of the torque-cadence profile and MDF in cyclists.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:24 |
---|---|
Enthalten in: |
Sensors (Basel, Switzerland) - 24(2024), 6 vom: 21. März |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Rodríguez-Rielves, Víctor [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 29.03.2024 Date Revised 30.03.2024 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.3390/s24061997 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM370338146 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM370338146 | ||
003 | DE-627 | ||
005 | 20240331002118.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240329s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/s24061997 |2 doi | |
028 | 5 | 2 | |a pubmed24n1357.xml |
035 | |a (DE-627)NLM370338146 | ||
035 | |a (NLM)38544265 | ||
035 | |a (PII)1997 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Rodríguez-Rielves, Víctor |e verfasserin |4 aut | |
245 | 1 | 0 | |a Torque-Cadence Profile and Maximal Dynamic Force in Cyclists |b A Novel Approach |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 29.03.2024 | ||
500 | |a Date Revised 30.03.2024 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a We aimed to determine the feasibility, test-retest reliability and long-term stability of a novel method for assessing the force (torque)-velocity (cadence) profile and maximal dynamic force (MDF) during leg-pedaling using a friction-loaded isoinertial cycle ergometer and a high-precision power-meter device. Fifty-two trained male cyclists completed a progressive loading test up to the one-repetition maximum (1RM) on a cycle ergometer. The MDF was defined as the force attained at the cycle performed with the 1RM-load. To examine the test-retest reliability and long-term stability of torque-cadence values, the progressive test was repeated after 72 h and also after 10 weeks of aerobic and strength training. The participants' MDF averaged 13.4 ± 1.3 N·kg-1, which was attained with an average pedal cadence of 21 ± 3 rpm. Participants' highest power output value was attained with a cadence of 110 ± 16 rpm (52 ± 5% MDF). The relationship between the MDF and cadence proved to be very strong (R2 = 0.978) and independent of the cyclists' MDF (p = 0.66). Cadence values derived from this relationship revealed a very high test-retest repeatability (mean SEM = 4 rpm, 3.3%) and long-term stability (SEM = 3 rpm, 2.3%); despite increases in the MDF following the 10-week period. Our findings support the validity, reliability and long-term stability of this method for the assessment of the torque-cadence profile and MDF in cyclists | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a assessment | |
650 | 4 | |a cycling | |
650 | 4 | |a force | |
650 | 4 | |a laboratory | |
650 | 4 | |a testing | |
700 | 1 | |a Barranco-Gil, David |e verfasserin |4 aut | |
700 | 1 | |a Buendía-Romero, Ángel |e verfasserin |4 aut | |
700 | 1 | |a Hernández-Belmonte, Alejandro |e verfasserin |4 aut | |
700 | 1 | |a Higueras-Liébana, Enrique |e verfasserin |4 aut | |
700 | 1 | |a Iriberri, Jon |e verfasserin |4 aut | |
700 | 1 | |a Sánchez-Redondo, Iván R |e verfasserin |4 aut | |
700 | 1 | |a Lillo-Beviá, José Ramón |e verfasserin |4 aut | |
700 | 1 | |a Martínez-Cava, Alejandro |e verfasserin |4 aut | |
700 | 1 | |a de Pablos, Raúl |e verfasserin |4 aut | |
700 | 1 | |a Valenzuela, Pedro L |e verfasserin |4 aut | |
700 | 1 | |a Pallarés, Jesús G |e verfasserin |4 aut | |
700 | 1 | |a Alejo, Lidia B |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Sensors (Basel, Switzerland) |d 2007 |g 24(2024), 6 vom: 21. März |w (DE-627)NLM187985170 |x 1424-8220 |7 nnns |
773 | 1 | 8 | |g volume:24 |g year:2024 |g number:6 |g day:21 |g month:03 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/s24061997 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 24 |j 2024 |e 6 |b 21 |c 03 |