Efficiency of the Vitamin D Status Diagnosticator amongst Geriatric Patients with COVID-19
The vitamin D status diagnosticator (VDSD), a 16-item tool, effectively identifies hypovitaminosis D in healthy older adults and can assist in determining the need for blood tests in this population. Assessing vitamin D levels is particularly crucial in the context of COVID-19. This study aimed to evaluate the VDSD's effectiveness in pinpointing hypovitaminosis D in older adults affected by COVID-19. The research involved 102 unsupplemented geriatric inpatients consecutively admitted to the acute geriatric division of Angers University Hospital, France, with an average age of 85.0 ± 5.9 years (47.1% women). The physician-administered VDSD was conducted simultaneously with the measurement of serum 25-hydroxyvitamin D (25(OH)D). Hypovitaminosis D was defined as a serum 25(OH)D concentration of ≤75 nmol/L for vitamin D insufficiency and ≤50 nmol/L for vitamin D deficiency. Results revealed that 87 participants (85.3%) had vitamin D insufficiency and 63 (61.8%) had vitamin D deficiency. The VDSD accurately identified vitamin D deficiency with an area under the curve (AUC) of 0.81 and an odds ratio (OR) of 40. However, its accuracy in identifying vitamin D insufficiency was lower (AUC = 0.57). In conclusion, the 16-item VDSD, a concise questionnaire, effectively identifies vitamin D deficiency in geriatric patients with COVID-19. This tool can be valuable in guiding the decision to administer vitamin D supplementation during the early stages of COVID-19.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:16 |
---|---|
Enthalten in: |
Nutrients - 16(2024), 6 vom: 15. März |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Charonnat, Caroline [VerfasserIn] |
---|
Links: |
---|
Themen: |
1406-16-2 |
---|
Anmerkungen: |
Date Completed 29.03.2024 Date Revised 30.03.2024 published: Electronic Citation Status MEDLINE |
---|
doi: |
10.3390/nu16060856 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM370323157 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM370323157 | ||
003 | DE-627 | ||
005 | 20240331001913.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240329s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/nu16060856 |2 doi | |
028 | 5 | 2 | |a pubmed24n1357.xml |
035 | |a (DE-627)NLM370323157 | ||
035 | |a (NLM)38542767 | ||
035 | |a (PII)856 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Charonnat, Caroline |e verfasserin |4 aut | |
245 | 1 | 0 | |a Efficiency of the Vitamin D Status Diagnosticator amongst Geriatric Patients with COVID-19 |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 29.03.2024 | ||
500 | |a Date Revised 30.03.2024 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a The vitamin D status diagnosticator (VDSD), a 16-item tool, effectively identifies hypovitaminosis D in healthy older adults and can assist in determining the need for blood tests in this population. Assessing vitamin D levels is particularly crucial in the context of COVID-19. This study aimed to evaluate the VDSD's effectiveness in pinpointing hypovitaminosis D in older adults affected by COVID-19. The research involved 102 unsupplemented geriatric inpatients consecutively admitted to the acute geriatric division of Angers University Hospital, France, with an average age of 85.0 ± 5.9 years (47.1% women). The physician-administered VDSD was conducted simultaneously with the measurement of serum 25-hydroxyvitamin D (25(OH)D). Hypovitaminosis D was defined as a serum 25(OH)D concentration of ≤75 nmol/L for vitamin D insufficiency and ≤50 nmol/L for vitamin D deficiency. Results revealed that 87 participants (85.3%) had vitamin D insufficiency and 63 (61.8%) had vitamin D deficiency. The VDSD accurately identified vitamin D deficiency with an area under the curve (AUC) of 0.81 and an odds ratio (OR) of 40. However, its accuracy in identifying vitamin D insufficiency was lower (AUC = 0.57). In conclusion, the 16-item VDSD, a concise questionnaire, effectively identifies vitamin D deficiency in geriatric patients with COVID-19. This tool can be valuable in guiding the decision to administer vitamin D supplementation during the early stages of COVID-19 | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a COVID-19 | |
650 | 4 | |a older adults | |
650 | 4 | |a screening | |
650 | 4 | |a vitamin D | |
650 | 4 | |a vitamin D deficiency | |
650 | 7 | |a Vitamin D |2 NLM | |
650 | 7 | |a 1406-16-2 |2 NLM | |
650 | 7 | |a Vitamins |2 NLM | |
700 | 1 | |a Sanchez-Rodriguez, Dolores |e verfasserin |4 aut | |
700 | 1 | |a Karras, Spyridon N |e verfasserin |4 aut | |
700 | 1 | |a Gezen-Ak, Duygu |e verfasserin |4 aut | |
700 | 1 | |a Dursun, Erdinç |e verfasserin |4 aut | |
700 | 1 | |a Annweiler, Cédric |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Nutrients |d 2009 |g 16(2024), 6 vom: 15. März |w (DE-627)NLM206140738 |x 2072-6643 |7 nnns |
773 | 1 | 8 | |g volume:16 |g year:2024 |g number:6 |g day:15 |g month:03 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/nu16060856 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 16 |j 2024 |e 6 |b 15 |c 03 |