Usefulness of Delay Time Setting in Computed Tomography Pulmonary Angiography
PURPOSE: During computed tomography pulmonary angiography (CTPA), a decrease in the CT value of the pulmonary artery may be observed due to poor contrast enhancement, even though the imaging is performed at the optimum timing while continuously injecting a contrast medium. This study focused on the increase in blood flow in the superior and inferior vena cava during inspiration that affects the decrease in the CT value of the pulmonary artery and investigated a radiography method in which a delay time was set after inspiration in clinical cases.
METHOD: A total of 50 patients who underwent CTPA for suspected pulmonary thromboembolism were included. Using the bolus tracking method, we monitored the pulmonary arteries before and after inspiration, and investigated the CT value changes.
RESULTS: A decrease in the CT value of the pulmonary artery after inspiration was observed in approximately 30% of cases. By setting the delay time, the contrast enhancement effect before and after inspiration became equivalent.
CONCLUSION: As a result of this study, avoiding a decrease in the CT value of the pulmonary artery is possible by setting a delay time after inspiration, which is considered useful during CTPA.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - year:2024 |
---|---|
Enthalten in: |
Nihon Hoshasen Gijutsu Gakkai zasshi - (2024) vom: 27. März |
Sprache: |
Japanisch |
---|
Beteiligte Personen: |
Kuramochi, Kenji [VerfasserIn] |
---|
Links: |
---|
Themen: |
Bolus tracking technique |
---|
Anmerkungen: |
Date Revised 27.03.2024 published: Print-Electronic Citation Status Publisher |
---|
doi: |
10.6009/jjrt.2024-1385 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM370278518 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM370278518 | ||
003 | DE-627 | ||
005 | 20240329001736.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240329s2024 xx |||||o 00| ||jpn c | ||
024 | 7 | |a 10.6009/jjrt.2024-1385 |2 doi | |
028 | 5 | 2 | |a pubmed24n1353.xml |
035 | |a (DE-627)NLM370278518 | ||
035 | |a (NLM)38538314 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a jpn | ||
100 | 1 | |a Kuramochi, Kenji |e verfasserin |4 aut | |
245 | 1 | 0 | |a Usefulness of Delay Time Setting in Computed Tomography Pulmonary Angiography |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 27.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status Publisher | ||
520 | |a PURPOSE: During computed tomography pulmonary angiography (CTPA), a decrease in the CT value of the pulmonary artery may be observed due to poor contrast enhancement, even though the imaging is performed at the optimum timing while continuously injecting a contrast medium. This study focused on the increase in blood flow in the superior and inferior vena cava during inspiration that affects the decrease in the CT value of the pulmonary artery and investigated a radiography method in which a delay time was set after inspiration in clinical cases | ||
520 | |a METHOD: A total of 50 patients who underwent CTPA for suspected pulmonary thromboembolism were included. Using the bolus tracking method, we monitored the pulmonary arteries before and after inspiration, and investigated the CT value changes | ||
520 | |a RESULTS: A decrease in the CT value of the pulmonary artery after inspiration was observed in approximately 30% of cases. By setting the delay time, the contrast enhancement effect before and after inspiration became equivalent | ||
520 | |a CONCLUSION: As a result of this study, avoiding a decrease in the CT value of the pulmonary artery is possible by setting a delay time after inspiration, which is considered useful during CTPA | ||
650 | 4 | |a English Abstract | |
650 | 4 | |a Journal Article | |
650 | 4 | |a Valsalva maneuver | |
650 | 4 | |a bolus tracking technique | |
650 | 4 | |a computed tomography (CT) | |
650 | 4 | |a computed tomography pulmonary angiography (CTPA) | |
700 | 1 | |a Sakashita, Taichi |e verfasserin |4 aut | |
700 | 1 | |a Ogawa, Yasuyoshi |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Nihon Hoshasen Gijutsu Gakkai zasshi |d 1993 |g (2024) vom: 27. März |w (DE-627)NLM074820923 |x 1881-4883 |7 nnns |
773 | 1 | 8 | |g year:2024 |g day:27 |g month:03 |
856 | 4 | 0 | |u http://dx.doi.org/10.6009/jjrt.2024-1385 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |j 2024 |b 27 |c 03 |