A hydrogel-based ratiometric fluorescent sensor relying on rhodamine B labelled AIE-featured hyperbranched poly(amido amine) for heparin detection
Copyright © 2024 Elsevier B.V. All rights reserved..
The fluorescent flexible sensor for point-of-care quantification of clinical anticoagulant drug, Heparin (Hep), is still an urgent need of breakthrough. In this research, a hyperbranched poly(amido amine) (HPA) was decorated with tetraphenylethene (TPE) and Rhodamine B (RhB), constructing a ratiometric fluorescent sensor (TR-HPA) for Hep. When the sensor was exposed to Hep, the TPE units within the probe skeleton would aggregate, resulting in an increasing fluorescent emission at 483 nm. The 580 nm of fluorescence came from RhB enhance, simultaneously, due to the fluorescence resonance energy transfer. As a result, there are two good linear correlation between the fluorescence emission ratio (E483/E580) of TR-HPA and the Hep concentration over a range of 0-1.0 μM, with a low limit of detection of 3.0 nM. Furthermore, we incorporate the TR-HPA probe into a polyvinyl alcohol (PVA) hydrogel matrix to create a flexible fluorescent sensing system platform, denoted as TR-HPA/PVA. This approach offers a straightforward visual detection method by causing a fluorescence color change from pink to blue when trace amounts of Hep are present. The hydrogel-based fluorescent sensor streamlines the detection procedures for Hep in biomedical applications. It shows great potential in rapid and point-of-care human blood clotting condition monitoring, making it suitable for next-generation wearable medical devices.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:1300 |
---|---|
Enthalten in: |
Analytica chimica acta - 1300(2024) vom: 29. März, Seite 342466 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Li, Cheng [VerfasserIn] |
---|
Links: |
---|
Themen: |
9005-49-6 |
---|
Anmerkungen: |
Date Completed 25.03.2024 Date Revised 25.03.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.aca.2024.342466 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM370111451 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM370111451 | ||
003 | DE-627 | ||
005 | 20240325235638.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240324s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.aca.2024.342466 |2 doi | |
028 | 5 | 2 | |a pubmed24n1347.xml |
035 | |a (DE-627)NLM370111451 | ||
035 | |a (NLM)38521573 | ||
035 | |a (PII)S0003-2670(24)00267-8 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Li, Cheng |e verfasserin |4 aut | |
245 | 1 | 2 | |a A hydrogel-based ratiometric fluorescent sensor relying on rhodamine B labelled AIE-featured hyperbranched poly(amido amine) for heparin detection |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 25.03.2024 | ||
500 | |a Date Revised 25.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2024 Elsevier B.V. All rights reserved. | ||
520 | |a The fluorescent flexible sensor for point-of-care quantification of clinical anticoagulant drug, Heparin (Hep), is still an urgent need of breakthrough. In this research, a hyperbranched poly(amido amine) (HPA) was decorated with tetraphenylethene (TPE) and Rhodamine B (RhB), constructing a ratiometric fluorescent sensor (TR-HPA) for Hep. When the sensor was exposed to Hep, the TPE units within the probe skeleton would aggregate, resulting in an increasing fluorescent emission at 483 nm. The 580 nm of fluorescence came from RhB enhance, simultaneously, due to the fluorescence resonance energy transfer. As a result, there are two good linear correlation between the fluorescence emission ratio (E483/E580) of TR-HPA and the Hep concentration over a range of 0-1.0 μM, with a low limit of detection of 3.0 nM. Furthermore, we incorporate the TR-HPA probe into a polyvinyl alcohol (PVA) hydrogel matrix to create a flexible fluorescent sensing system platform, denoted as TR-HPA/PVA. This approach offers a straightforward visual detection method by causing a fluorescence color change from pink to blue when trace amounts of Hep are present. The hydrogel-based fluorescent sensor streamlines the detection procedures for Hep in biomedical applications. It shows great potential in rapid and point-of-care human blood clotting condition monitoring, making it suitable for next-generation wearable medical devices | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Detection | |
650 | 4 | |a Fluorescence | |
650 | 4 | |a Heparin | |
650 | 4 | |a Hydrogel | |
650 | 4 | |a Hyperbranched poly(amido amine) | |
650 | 7 | |a rhodamine B |2 NLM | |
650 | 7 | |a K7G5SCF8IL |2 NLM | |
650 | 7 | |a Heparin |2 NLM | |
650 | 7 | |a 9005-49-6 |2 NLM | |
650 | 7 | |a Fluorescent Dyes |2 NLM | |
650 | 7 | |a Amines |2 NLM | |
650 | 7 | |a Hydrogels |2 NLM | |
650 | 7 | |a Rhodamines |2 NLM | |
700 | 1 | |a Liu, Bai-Tong |e verfasserin |4 aut | |
700 | 1 | |a Wang, Yi-Ting |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Tian-Jiao |e verfasserin |4 aut | |
700 | 1 | |a Zheng, Xiaochun |e verfasserin |4 aut | |
700 | 1 | |a Chen, Li |e verfasserin |4 aut | |
700 | 1 | |a Li, Shaobo |e verfasserin |4 aut | |
700 | 1 | |a Tian, Xiaoxian |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Dequan |e verfasserin |4 aut | |
700 | 1 | |a Wang, Yong |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Analytica chimica acta |d 1966 |g 1300(2024) vom: 29. März, Seite 342466 |w (DE-627)NLM000012637 |x 1873-4324 |7 nnns |
773 | 1 | 8 | |g volume:1300 |g year:2024 |g day:29 |g month:03 |g pages:342466 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.aca.2024.342466 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 1300 |j 2024 |b 29 |c 03 |h 342466 |