Evidence for the induction of analgesic cross-tolerance between opioid and apelin/APJ systems in male rats
BACKGROUND: Opioids are potent pain relievers for managing severe pain. However, their effectiveness is hindered by tolerance, which causes the need for higher doses and leads to adverse effects. In a previous study, we found that prolonged use of apelin, similar to opioids, results in a tolerance to its analgesic effects. It remains unclear whether there is a cross-tolerance between morphine and apelin, meaning if the analgesic effects of one can reduce the effectiveness of the other.
METHODS: The tail-flick test was used to assess the nociceptive threshold. All experiments were carried out on 63 male Wistar rats, which received intrathecal apelin (3µg/rat) or morphine (15µg/rat) for 7 days. To determine cross-tolerance between the analgesic effect of morphine and apelin, the analgesic property of apelin or morphine was assessed in chronic morphine- or apelin-treated groups, respectively. To determine the role of apelin and opioid receptors signaling on the development of analgesic cross-tolerance, F13-A and naloxone, as apelin and opioid receptor antagonists, were injected simultaneously with morphine or apelin. At the end of the tests, the expression levels of apelin and mu-opioid receptors were evaluated by western blotting.
RESULTS: The data indicated that chronic apelin or morphine produced tolerance to the antinociceptive effects of each other. F13-A and naloxone could inhibit the induction of such cross-tolerance. The molecular data showed that there was a significant downregulation of apelin receptors in chronic morphine-treated rats and vice versa.
CONCLUSION: Chronic administration of apelin or morphine induces analgesic cross-tolerance that may, in part, be mediated through receptor interactions and downregulation. The demonstrated efficacy of F13-A in these experiments highlights its potential as a novel target for improving pain management through the inhibition of the apelin/APJ signaling pathway, meriting further investigation.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - year:2024 |
---|---|
Enthalten in: |
Journal of studies on alcohol and drugs - (2024) vom: 22. März |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Abbasloo, Elham [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Revised 23.03.2024 published: Print-Electronic Citation Status Publisher |
---|
doi: |
10.15288/jsad.23-00377 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM370073215 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM370073215 | ||
003 | DE-627 | ||
005 | 20240323235925.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240323s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.15288/jsad.23-00377 |2 doi | |
028 | 5 | 2 | |a pubmed24n1343.xml |
035 | |a (DE-627)NLM370073215 | ||
035 | |a (NLM)38517751 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Abbasloo, Elham |e verfasserin |4 aut | |
245 | 1 | 0 | |a Evidence for the induction of analgesic cross-tolerance between opioid and apelin/APJ systems in male rats |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 23.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status Publisher | ||
520 | |a BACKGROUND: Opioids are potent pain relievers for managing severe pain. However, their effectiveness is hindered by tolerance, which causes the need for higher doses and leads to adverse effects. In a previous study, we found that prolonged use of apelin, similar to opioids, results in a tolerance to its analgesic effects. It remains unclear whether there is a cross-tolerance between morphine and apelin, meaning if the analgesic effects of one can reduce the effectiveness of the other | ||
520 | |a METHODS: The tail-flick test was used to assess the nociceptive threshold. All experiments were carried out on 63 male Wistar rats, which received intrathecal apelin (3µg/rat) or morphine (15µg/rat) for 7 days. To determine cross-tolerance between the analgesic effect of morphine and apelin, the analgesic property of apelin or morphine was assessed in chronic morphine- or apelin-treated groups, respectively. To determine the role of apelin and opioid receptors signaling on the development of analgesic cross-tolerance, F13-A and naloxone, as apelin and opioid receptor antagonists, were injected simultaneously with morphine or apelin. At the end of the tests, the expression levels of apelin and mu-opioid receptors were evaluated by western blotting | ||
520 | |a RESULTS: The data indicated that chronic apelin or morphine produced tolerance to the antinociceptive effects of each other. F13-A and naloxone could inhibit the induction of such cross-tolerance. The molecular data showed that there was a significant downregulation of apelin receptors in chronic morphine-treated rats and vice versa | ||
520 | |a CONCLUSION: Chronic administration of apelin or morphine induces analgesic cross-tolerance that may, in part, be mediated through receptor interactions and downregulation. The demonstrated efficacy of F13-A in these experiments highlights its potential as a novel target for improving pain management through the inhibition of the apelin/APJ signaling pathway, meriting further investigation | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Analgesia | |
650 | 4 | |a Apelin | |
650 | 4 | |a Cross-Tolerance | |
650 | 4 | |a Morphine | |
650 | 4 | |a Rats | |
700 | 1 | |a Esmaeili-Mahani, Saeed |e verfasserin |4 aut | |
700 | 1 | |a Kobeissy, Firas |e verfasserin |4 aut | |
700 | 1 | |a Thomas, Theresa Currier |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of studies on alcohol and drugs |d 2007 |g (2024) vom: 22. März |w (DE-627)NLM167005537 |x 1938-4114 |7 nnns |
773 | 1 | 8 | |g year:2024 |g day:22 |g month:03 |
856 | 4 | 0 | |u http://dx.doi.org/10.15288/jsad.23-00377 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |j 2024 |b 22 |c 03 |