The Effects of Exercise on Cardiogenic Shock with an Intra-Aortic Balloon Pump : A Case Report
This case report describes the exercise program on a hospitalized 54-year-old male patient with cardiogenic shock waiting for a heart transplant assisted by an intra-aortic balloon pump, a temporary mechanical circulatory support device. The temporary mechanical circulatory support device, an intra-aortic balloon pump, was placed in the left subclavian artery, enabling the exercise protocol. Measurements and values from Swan-Ganz catheter, blood sample, brain natriuretic peptide (NT-proBNP), and high-sensitivity C-reactive protein (hs-CRP), as well as the six-minute walk test (6MWT) and venous oxygen saturation (SvO2) were obtained before and after an exercise protocol. The exercise training protocol involved the use of an unloaded bed cycle ergometer once a day, for a maximum of 30 minutes, to the tolerance limit. No adverse events or events related to the dislocation of the intra-aortic balloon pump were observed during the exercise protocol. The exercise program resulted in higher SvO2 levels, with an increased 6MWT with lower Borg dyspnea scores (312 meters vs. 488 meters and five points vs. three points, respectively). After completing the ten-day exercise protocol, the patient underwent a non-complicated heart transplant surgery and a full recovery in the ICU. This study showed that exercise is a feasible option for patients with cardiogenic shock who are using an intra-aortic balloon pump and that it is well-tolerated with no reported adverse events.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:121 |
---|---|
Enthalten in: |
Arquivos brasileiros de cardiologia - 121(2024), 1 vom: 20., Seite e20230537 |
Sprache: |
Portugiesisch |
---|
Weiterer Titel: |
Efeitos do Exercício em Choque Cardiogênico e Balão Intra-Aórtico: Um Relato de Caso |
---|
Beteiligte Personen: |
Ferreira, Vanessa M [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 22.03.2024 Date Revised 22.03.2024 published: Electronic-eCollection Citation Status MEDLINE |
---|
doi: |
10.36660/abc.20230537 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM370013824 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM370013824 | ||
003 | DE-627 | ||
005 | 20240323001649.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240322s2024 xx |||||o 00| ||por c | ||
024 | 7 | |a 10.36660/abc.20230537 |2 doi | |
028 | 5 | 2 | |a pubmed24n1341.xml |
035 | |a (DE-627)NLM370013824 | ||
035 | |a (NLM)38511808 | ||
035 | |a (PII)S0066-782X2024000100701 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a por | ||
100 | 1 | |a Ferreira, Vanessa M |e verfasserin |4 aut | |
245 | 1 | 4 | |a The Effects of Exercise on Cardiogenic Shock with an Intra-Aortic Balloon Pump |b A Case Report |
246 | 3 | 3 | |a Efeitos do Exercício em Choque Cardiogênico e Balão Intra-Aórtico: Um Relato de Caso |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 22.03.2024 | ||
500 | |a Date Revised 22.03.2024 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status MEDLINE | ||
520 | |a This case report describes the exercise program on a hospitalized 54-year-old male patient with cardiogenic shock waiting for a heart transplant assisted by an intra-aortic balloon pump, a temporary mechanical circulatory support device. The temporary mechanical circulatory support device, an intra-aortic balloon pump, was placed in the left subclavian artery, enabling the exercise protocol. Measurements and values from Swan-Ganz catheter, blood sample, brain natriuretic peptide (NT-proBNP), and high-sensitivity C-reactive protein (hs-CRP), as well as the six-minute walk test (6MWT) and venous oxygen saturation (SvO2) were obtained before and after an exercise protocol. The exercise training protocol involved the use of an unloaded bed cycle ergometer once a day, for a maximum of 30 minutes, to the tolerance limit. No adverse events or events related to the dislocation of the intra-aortic balloon pump were observed during the exercise protocol. The exercise program resulted in higher SvO2 levels, with an increased 6MWT with lower Borg dyspnea scores (312 meters vs. 488 meters and five points vs. three points, respectively). After completing the ten-day exercise protocol, the patient underwent a non-complicated heart transplant surgery and a full recovery in the ICU. This study showed that exercise is a feasible option for patients with cardiogenic shock who are using an intra-aortic balloon pump and that it is well-tolerated with no reported adverse events | ||
650 | 4 | |a Case Reports | |
700 | 1 | |a Rodrigues, Dayane Nunes |e verfasserin |4 aut | |
700 | 1 | |a Contreras, Carlos Alberto Mendez |e verfasserin |4 aut | |
700 | 1 | |a Rossi, João M |e verfasserin |4 aut | |
700 | 1 | |a Ramos, Rui Fernando |e verfasserin |4 aut | |
700 | 1 | |a Oliveira, Gustavo |e verfasserin |4 aut | |
700 | 1 | |a Oliveira, Mayron F |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Arquivos brasileiros de cardiologia |d 1950 |g 121(2024), 1 vom: 20., Seite e20230537 |w (DE-627)NLM000272981 |x 1678-4170 |7 nnns |
773 | 1 | 8 | |g volume:121 |g year:2024 |g number:1 |g day:20 |g pages:e20230537 |
856 | 4 | 0 | |u http://dx.doi.org/10.36660/abc.20230537 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 121 |j 2024 |e 1 |b 20 |h e20230537 |