Identification rate of Legionella species in non-purulent sputum culture is comparable to that in purulent sputum culture in Legionella pneumonia
Many Legionella pneumonia patients do not produce sputum, and it is unknown whether purulent sputum is required for the identification of Legionella species. This study aimed to evaluate the identification rate of Legionella species based on sputum quality and the factors predictive of Legionella infection. This study included Legionella pneumonia patients at Kurashiki Central Hospital from November 2000 to December 2022. Sputum quality, based on gram staining, was classified as the following: Geckler 1/2, 3/6 and 4/5. Geckler 4/5 was defined as purulent sputum. The sputa of 104 of 124 Legionella pneumonia patients were cultured. Fifty-four patients (51.9%) were identified with Legionella species, most of which were Legionella pneumophila serogroup 1 (81.5%). The identification rates of Legionella species according to sputum quality were 57.1% (16/28) in Geckler 1/2 sputum, 50.0% (34/68) in Geckler 3/6 sputum, and 50.0% (4/8) in Geckler 4/5 sputum, which were not significantly different (P = 0.86). On multivariate analysis, pre-culture treatment with anti-Legionella antimicrobials (odds ratio [OR] 0.26, 95% confidence interval [CI] 0.06-0.91), Pneumonia Severity Index class ≥IV (OR 2.57 [95% CI 1.02-6.71]), and intensive care unit admission (OR 3.08, 95% CI 1.06-10.09) correlated with the ability to identify Legionella species, but sputum quality did not (OR 0.88, 95% CI 0.17-4.41). The identification rate of Legionella species in non-purulent sputum was similar to that in purulent sputum. For the diagnosis of Legionella pneumonia, sputum should be collected before administering anti-Legionella antibiotics and cultured regardless of sputum quality.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:62 |
---|---|
Enthalten in: |
Journal of clinical microbiology - 62(2024), 4 vom: 10. Apr., Seite e0166523 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Ito, Akihiro [VerfasserIn] |
---|
Links: |
---|
Themen: |
Diagnosis |
---|
Anmerkungen: |
Date Completed 11.04.2024 Date Revised 12.04.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1128/jcm.01665-23 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM369913019 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM369913019 | ||
003 | DE-627 | ||
005 | 20240412233043.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240319s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1128/jcm.01665-23 |2 doi | |
028 | 5 | 2 | |a pubmed24n1373.xml |
035 | |a (DE-627)NLM369913019 | ||
035 | |a (NLM)38501659 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Ito, Akihiro |e verfasserin |4 aut | |
245 | 1 | 0 | |a Identification rate of Legionella species in non-purulent sputum culture is comparable to that in purulent sputum culture in Legionella pneumonia |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 11.04.2024 | ||
500 | |a Date Revised 12.04.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Many Legionella pneumonia patients do not produce sputum, and it is unknown whether purulent sputum is required for the identification of Legionella species. This study aimed to evaluate the identification rate of Legionella species based on sputum quality and the factors predictive of Legionella infection. This study included Legionella pneumonia patients at Kurashiki Central Hospital from November 2000 to December 2022. Sputum quality, based on gram staining, was classified as the following: Geckler 1/2, 3/6 and 4/5. Geckler 4/5 was defined as purulent sputum. The sputa of 104 of 124 Legionella pneumonia patients were cultured. Fifty-four patients (51.9%) were identified with Legionella species, most of which were Legionella pneumophila serogroup 1 (81.5%). The identification rates of Legionella species according to sputum quality were 57.1% (16/28) in Geckler 1/2 sputum, 50.0% (34/68) in Geckler 3/6 sputum, and 50.0% (4/8) in Geckler 4/5 sputum, which were not significantly different (P = 0.86). On multivariate analysis, pre-culture treatment with anti-Legionella antimicrobials (odds ratio [OR] 0.26, 95% confidence interval [CI] 0.06-0.91), Pneumonia Severity Index class ≥IV (OR 2.57 [95% CI 1.02-6.71]), and intensive care unit admission (OR 3.08, 95% CI 1.06-10.09) correlated with the ability to identify Legionella species, but sputum quality did not (OR 0.88, 95% CI 0.17-4.41). The identification rate of Legionella species in non-purulent sputum was similar to that in purulent sputum. For the diagnosis of Legionella pneumonia, sputum should be collected before administering anti-Legionella antibiotics and cultured regardless of sputum quality | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Legionella pneumonia | |
650 | 4 | |a diagnosis | |
650 | 4 | |a predictive factor | |
650 | 4 | |a purulent sputum | |
650 | 4 | |a sputum culture | |
700 | 1 | |a Ishida, Tadashi |e verfasserin |4 aut | |
700 | 1 | |a Tachibana, Hiromasa |e verfasserin |4 aut | |
700 | 1 | |a Nakanishi, Yosuke |e verfasserin |4 aut | |
700 | 1 | |a Kawataki, Masanori |e verfasserin |4 aut | |
700 | 1 | |a Yamazaki, Akio |e verfasserin |4 aut | |
700 | 1 | |a Washio, Yasuyoshi |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of clinical microbiology |d 1975 |g 62(2024), 4 vom: 10. Apr., Seite e0166523 |w (DE-627)NLM000005460 |x 1098-660X |7 nnns |
773 | 1 | 8 | |g volume:62 |g year:2024 |g number:4 |g day:10 |g month:04 |g pages:e0166523 |
856 | 4 | 0 | |u http://dx.doi.org/10.1128/jcm.01665-23 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 62 |j 2024 |e 4 |b 10 |c 04 |h e0166523 |