Afterglow Nanoprobe-Enabled Quantitative Lateral Flow Immunoassay by a Palm-Size Device for Household Healthcare
Lateral flow immunoassay (LFIA), a classical point-of-care testing (POCT) technique, plays an important role in disease screening and healthcare monitoring. However, traditional LFIA is either designed for qualitative analysis or requires expensive equipment for quantification, limiting its use in household diagnosis. In this study, we proposed a new generation of LFIA for household health monitoring by using ultralong organic phosphorescence (UOP) nanomaterials as afterglow nanoprobes with a self-developed palm-size sensing device. The UOP nanoprobes exhibit a phosphorescence signal with a second-level lifetime, which completely avoids the interference from excitation light and biological background fluorescence. Therefore, an ultraminiaturized and low-cost UOP nanosensor was successfully designed by eliminating the complex optical path and filtering systems. We chose an inflammatory factor, C-reactive protein (CRP), for household POCT validation. The whole analysis was completed within 9 min. A limit of detection (LOD) of 0.54 ng/mL of CRP antigen was achieved with high stability and good specificity, which is comparable to laboratory instruments and fully satisfying the clinical diagnosis requirement.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:96 |
---|---|
Enthalten in: |
Analytical chemistry - 96(2024), 12 vom: 26. März, Seite 4891-4900 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Guo, Jiuchuan [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 27.03.2024 Date Revised 27.03.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1021/acs.analchem.3c05448 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM369524063 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM369524063 | ||
003 | DE-627 | ||
005 | 20240328000110.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240311s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1021/acs.analchem.3c05448 |2 doi | |
028 | 5 | 2 | |a pubmed24n1351.xml |
035 | |a (DE-627)NLM369524063 | ||
035 | |a (NLM)38462674 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Guo, Jiuchuan |e verfasserin |4 aut | |
245 | 1 | 0 | |a Afterglow Nanoprobe-Enabled Quantitative Lateral Flow Immunoassay by a Palm-Size Device for Household Healthcare |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 27.03.2024 | ||
500 | |a Date Revised 27.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Lateral flow immunoassay (LFIA), a classical point-of-care testing (POCT) technique, plays an important role in disease screening and healthcare monitoring. However, traditional LFIA is either designed for qualitative analysis or requires expensive equipment for quantification, limiting its use in household diagnosis. In this study, we proposed a new generation of LFIA for household health monitoring by using ultralong organic phosphorescence (UOP) nanomaterials as afterglow nanoprobes with a self-developed palm-size sensing device. The UOP nanoprobes exhibit a phosphorescence signal with a second-level lifetime, which completely avoids the interference from excitation light and biological background fluorescence. Therefore, an ultraminiaturized and low-cost UOP nanosensor was successfully designed by eliminating the complex optical path and filtering systems. We chose an inflammatory factor, C-reactive protein (CRP), for household POCT validation. The whole analysis was completed within 9 min. A limit of detection (LOD) of 0.54 ng/mL of CRP antigen was achieved with high stability and good specificity, which is comparable to laboratory instruments and fully satisfying the clinical diagnosis requirement | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Zhou, Yudong |e verfasserin |4 aut | |
700 | 1 | |a Cheng, Jie |e verfasserin |4 aut | |
700 | 1 | |a Chen, Fuli |e verfasserin |4 aut | |
700 | 1 | |a Xu, Jiahui |e verfasserin |4 aut | |
700 | 1 | |a Yang, Lirong |e verfasserin |4 aut | |
700 | 1 | |a Shi, Huifang |e verfasserin |4 aut | |
700 | 1 | |a An, Zhongfu |e verfasserin |4 aut | |
700 | 1 | |a Guo, Jinhong |e verfasserin |4 aut | |
700 | 1 | |a Ma, Xing |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Analytical chemistry |d 1965 |g 96(2024), 12 vom: 26. März, Seite 4891-4900 |w (DE-627)NLM000025771 |x 1520-6882 |7 nnns |
773 | 1 | 8 | |g volume:96 |g year:2024 |g number:12 |g day:26 |g month:03 |g pages:4891-4900 |
856 | 4 | 0 | |u http://dx.doi.org/10.1021/acs.analchem.3c05448 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 96 |j 2024 |e 12 |b 26 |c 03 |h 4891-4900 |