2.5-Minute Fast Brain MRI with Multiple Contrasts in Acute Ischemic Stroke
© 2024. The Author(s)..
PURPOSE: To assess the performance of a 2.5-minute multi-contrast brain MRI sequence (NeuroMix) in diagnosing acute cerebral infarctions.
METHODS: Adult patients with a clinical suspicion of acute ischemic stroke were retrospectively included. Brain MRI at 3 T included NeuroMix and routine clinical MRI (cMRI) sequences, with DWI/ADC, T2-FLAIR, T2-weighted, T2*, SWI-EPI, and T1-weighted contrasts. Three radiologists (R1-3) independently assessed NeuroMix and cMRI for the presence of acute infarcts (DWI ↑, ADC = or ↓) and infarct-associated abnormalities on other image contrasts. Sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC) were calculated and compared using DeLong's test. Inter- and intra-rater agreements were studied with kappa statistics. Relative DWI (rDWI) and T2-FLAIR (rT2-FLAIR) signal intensity for infarctions were semi-automatically rendered, and the correlation between methods was evaluated.
RESULTS: According to the reference standard, acute infarction was present in 34 out of 44 (77%) patients (63 ± 17 years, 31 men). Other infarct-associated signal abnormalities were reported in similar frequencies on NeuroMix and cMRI (p > .08). Sensitivity for infarction detection was 94%, 100%, and 94% evaluated by R1, R2, R3, for NeuroMix and 94%, 100%, and 100% for cMRI. Specificity was 100%, 90%, and 100% for NeuroMix and 100%, 100%, and 100% for cMRI. AUC for NeuroMix was .97, .95, and .97 and .97, 1, and 1 for cMRI (DeLong p = 1, .32, .15), respectively. Inter- and intra-rater agreement was κ = .88-1. The correlation between NeuroMix and cMRI was R = .73 for rDWI and R = .83 for rT2-FLAIR.
CONCLUSION: Fast multi-contrast MRI NeuroMix has high diagnostic performance for detecting acute cerebral infarctions.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:66 |
---|---|
Enthalten in: |
Neuroradiology - 66(2024), 5 vom: 02. Apr., Seite 737-747 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Kits, Annika [VerfasserIn] |
---|
Links: |
---|
Themen: |
DWI/T2-FLAIR mismatch |
---|
Anmerkungen: |
Date Completed 22.04.2024 Date Revised 26.04.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1007/s00234-024-03331-0 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM369523113 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM369523113 | ||
003 | DE-627 | ||
005 | 20240426233857.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240311s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1007/s00234-024-03331-0 |2 doi | |
028 | 5 | 2 | |a pubmed24n1388.xml |
035 | |a (DE-627)NLM369523113 | ||
035 | |a (NLM)38462584 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Kits, Annika |e verfasserin |4 aut | |
245 | 1 | 0 | |a 2.5-Minute Fast Brain MRI with Multiple Contrasts in Acute Ischemic Stroke |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 22.04.2024 | ||
500 | |a Date Revised 26.04.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a © 2024. The Author(s). | ||
520 | |a PURPOSE: To assess the performance of a 2.5-minute multi-contrast brain MRI sequence (NeuroMix) in diagnosing acute cerebral infarctions | ||
520 | |a METHODS: Adult patients with a clinical suspicion of acute ischemic stroke were retrospectively included. Brain MRI at 3 T included NeuroMix and routine clinical MRI (cMRI) sequences, with DWI/ADC, T2-FLAIR, T2-weighted, T2*, SWI-EPI, and T1-weighted contrasts. Three radiologists (R1-3) independently assessed NeuroMix and cMRI for the presence of acute infarcts (DWI ↑, ADC = or ↓) and infarct-associated abnormalities on other image contrasts. Sensitivity, specificity, and the area under the receiver operating characteristic curve (AUC) were calculated and compared using DeLong's test. Inter- and intra-rater agreements were studied with kappa statistics. Relative DWI (rDWI) and T2-FLAIR (rT2-FLAIR) signal intensity for infarctions were semi-automatically rendered, and the correlation between methods was evaluated | ||
520 | |a RESULTS: According to the reference standard, acute infarction was present in 34 out of 44 (77%) patients (63 ± 17 years, 31 men). Other infarct-associated signal abnormalities were reported in similar frequencies on NeuroMix and cMRI (p > .08). Sensitivity for infarction detection was 94%, 100%, and 94% evaluated by R1, R2, R3, for NeuroMix and 94%, 100%, and 100% for cMRI. Specificity was 100%, 90%, and 100% for NeuroMix and 100%, 100%, and 100% for cMRI. AUC for NeuroMix was .97, .95, and .97 and .97, 1, and 1 for cMRI (DeLong p = 1, .32, .15), respectively. Inter- and intra-rater agreement was κ = .88-1. The correlation between NeuroMix and cMRI was R = .73 for rDWI and R = .83 for rT2-FLAIR | ||
520 | |a CONCLUSION: Fast multi-contrast MRI NeuroMix has high diagnostic performance for detecting acute cerebral infarctions | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a DWI/T2-FLAIR mismatch | |
650 | 4 | |a Diagnostic performance | |
650 | 4 | |a Fast imaging | |
650 | 4 | |a Ischemic stroke | |
650 | 4 | |a Multi-contrast MRI | |
650 | 4 | |a NeuroMix | |
700 | 1 | |a Al-Saadi, Jonathan |e verfasserin |4 aut | |
700 | 1 | |a De Luca, Francesca |e verfasserin |4 aut | |
700 | 1 | |a Janzon, Fredrik |e verfasserin |4 aut | |
700 | 1 | |a Mazya, Michael V |e verfasserin |4 aut | |
700 | 1 | |a Lundberg, Johan |e verfasserin |4 aut | |
700 | 1 | |a Sprenger, Tim |e verfasserin |4 aut | |
700 | 1 | |a Skare, Stefan |e verfasserin |4 aut | |
700 | 1 | |a Delgado, Anna Falk |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Neuroradiology |d 1971 |g 66(2024), 5 vom: 02. Apr., Seite 737-747 |w (DE-627)NLM000263672 |x 1432-1920 |7 nnns |
773 | 1 | 8 | |g volume:66 |g year:2024 |g number:5 |g day:02 |g month:04 |g pages:737-747 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s00234-024-03331-0 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 66 |j 2024 |e 5 |b 02 |c 04 |h 737-747 |