Insight into roles of carbon anodes for removal of refractory organic contaminants in electro-peroxone system : Mechanism, performance and stability
Copyright © 2024 Elsevier B.V. All rights reserved..
Electro-peroxone (EP) is a novel technique for the removal of refractory organic contaminants (ROCs), while the role of anode in this system is neglected. In this work, the EP system with graphite felt anode (EP-GF) and activated carbon fiber anode (EP-ACF) was developed to enhance ibuprofen (IBP) removal. The results showed that 91.2% and 98.6% of IBP was removed within 20 min in EP-GF and EP-ACF, respectively. Hydroxy radical (O⋅H) was identified as the dominant reactive species, contributing 80.9% and 54.0% of IBP removal in EP-ACF and EP-GF systems, respectively. The roles of adsorption in EP-ACF and direct electron transfer in EP-GF cannot be ignored. Due to the differences in mechanism, EP-GF and EP-ACF systems were suitable for the removal of O⋅H-resistant ROCs (e.g., oxalic acid and pyruvic acid) and non-O⋅H-resistant ROCs (e.g., IBP and nitrobenzene), respectively. Both systems had excellent stability relying on the introduction of oxygen functional groups on the anode, and their electrolysis energy consumption was significantly lower than that of EP-Pt system. The three degradation pathways of IBP were proposed, and the toxicity of intermediates were evaluated. In general, carbon anodes have a good application prospect in the removal of ROCs in EP systems.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:469 |
---|---|
Enthalten in: |
Journal of hazardous materials - 469(2024) vom: 05. Apr., Seite 133957 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Dong, Zekun [VerfasserIn] |
---|
Links: |
---|
Themen: |
Carbon anode |
---|
Anmerkungen: |
Date Revised 06.04.2024 published: Print-Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1016/j.jhazmat.2024.133957 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM369424301 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM369424301 | ||
003 | DE-627 | ||
005 | 20240407232340.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240308s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jhazmat.2024.133957 |2 doi | |
028 | 5 | 2 | |a pubmed24n1368.xml |
035 | |a (DE-627)NLM369424301 | ||
035 | |a (NLM)38452678 | ||
035 | |a (PII)S0304-3894(24)00536-3 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Dong, Zekun |e verfasserin |4 aut | |
245 | 1 | 0 | |a Insight into roles of carbon anodes for removal of refractory organic contaminants in electro-peroxone system |b Mechanism, performance and stability |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 06.04.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Copyright © 2024 Elsevier B.V. All rights reserved. | ||
520 | |a Electro-peroxone (EP) is a novel technique for the removal of refractory organic contaminants (ROCs), while the role of anode in this system is neglected. In this work, the EP system with graphite felt anode (EP-GF) and activated carbon fiber anode (EP-ACF) was developed to enhance ibuprofen (IBP) removal. The results showed that 91.2% and 98.6% of IBP was removed within 20 min in EP-GF and EP-ACF, respectively. Hydroxy radical (O⋅H) was identified as the dominant reactive species, contributing 80.9% and 54.0% of IBP removal in EP-ACF and EP-GF systems, respectively. The roles of adsorption in EP-ACF and direct electron transfer in EP-GF cannot be ignored. Due to the differences in mechanism, EP-GF and EP-ACF systems were suitable for the removal of O⋅H-resistant ROCs (e.g., oxalic acid and pyruvic acid) and non-O⋅H-resistant ROCs (e.g., IBP and nitrobenzene), respectively. Both systems had excellent stability relying on the introduction of oxygen functional groups on the anode, and their electrolysis energy consumption was significantly lower than that of EP-Pt system. The three degradation pathways of IBP were proposed, and the toxicity of intermediates were evaluated. In general, carbon anodes have a good application prospect in the removal of ROCs in EP systems | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Carbon anode | |
650 | 4 | |a DFT | |
650 | 4 | |a Dynamics | |
650 | 4 | |a Electro-peroxone | |
650 | 4 | |a Refractory organic contaminants | |
700 | 1 | |a Yao, Jie |e verfasserin |4 aut | |
700 | 1 | |a Hu, Zhihui |e verfasserin |4 aut | |
700 | 1 | |a Yang, Jiao |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Yan |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of hazardous materials |d 1998 |g 469(2024) vom: 05. Apr., Seite 133957 |w (DE-627)NLM093662688 |x 1873-3336 |7 nnns |
773 | 1 | 8 | |g volume:469 |g year:2024 |g day:05 |g month:04 |g pages:133957 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jhazmat.2024.133957 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 469 |j 2024 |b 05 |c 04 |h 133957 |