Successful Suture-Free Repair of Left Ventricular Rupture Using the EVARREST Patch

© 2024 The Authors. Published by The Texas Heart Institute®..

Left ventricular free wall rupture is a lethal complication of myocardial infarction. Although emergent surgical repair is the treatment of choice, the method of repair remains highly individualized. This report presents a case of spontaneous coronary artery dissection in a patient with Turner syndrome that led to left ventricular free wall rupture and was successfully repaired on cardiopulmonary bypass using a suture-free technique with the EVARREST Fibrin Sealant Patch.