The importance of interdigitating screw fixation of the trochlea in double plate osteosynthesis of low transcondylar distal humerus fractures : A biomechanical study
Copyright © 2024. Published by Elsevier Ltd..
OBJECTIVE: The trochlea is of great importance for the stability of the elbow and its fixation in low transcondylar fractures of the distal humerus is especially challenging. The aim of this study was to determine the optimal trochlea fixation in double plate osteosynthesis of intraarticular distal humerus fractures.
METHODS: A low transcondylar, C3-type distal humerus fracture was created in 20 fresh-frozen human cadaveric humeri. The samples were then randomly divided into two groups of 10 specimens each. Double plate osteosynthesis was performed in both groups. In group A, the two most distal screws of the lateral plate were inserted into the trochlea fragment. In group B, these screws did not extend into the trochlea. Displacement under cyclic loading and ultimate failure loads were determined for all specimens.
RESULTS: Group A showed significantly less displacement under cyclic loading in each measurement interval (0.92 mm vs. 1.53 mm after 100 cycles, p = 0 0.006; 1.10 mm vs. 1.84 mm after 1000 cycles, p = 0.007; 1.18 mm vs. 1.98 mm after 2000 cycles, p = 0.008). The ultimate failure load was significantly higher in group A than in group B (345.61 ± 120.389 N vs. 238.42 ± 131.61 N, p = 0.037).
CONCLUSIONS: Fixation of the trochlea with interdigitating screws in double plate osteosynthesis of low-condylar type C distal humerus fractures results in superior construct stability.
LEVEL OF EVIDENCE: not applicable (biomechanical).
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:55 |
---|---|
Enthalten in: |
Injury - 55(2024), 4 vom: 15. März, Seite 111486 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Lappen, Sebastian [VerfasserIn] |
---|
Links: |
---|
Themen: |
Distal humerus |
---|
Anmerkungen: |
Date Completed 19.03.2024 Date Revised 19.03.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.injury.2024.111486 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM369372476 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM369372476 | ||
003 | DE-627 | ||
005 | 20240319232931.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240307s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.injury.2024.111486 |2 doi | |
028 | 5 | 2 | |a pubmed24n1336.xml |
035 | |a (DE-627)NLM369372476 | ||
035 | |a (NLM)38447478 | ||
035 | |a (PII)S0020-1383(24)00173-6 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Lappen, Sebastian |e verfasserin |4 aut | |
245 | 1 | 4 | |a The importance of interdigitating screw fixation of the trochlea in double plate osteosynthesis of low transcondylar distal humerus fractures |b A biomechanical study |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 19.03.2024 | ||
500 | |a Date Revised 19.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2024. Published by Elsevier Ltd. | ||
520 | |a OBJECTIVE: The trochlea is of great importance for the stability of the elbow and its fixation in low transcondylar fractures of the distal humerus is especially challenging. The aim of this study was to determine the optimal trochlea fixation in double plate osteosynthesis of intraarticular distal humerus fractures | ||
520 | |a METHODS: A low transcondylar, C3-type distal humerus fracture was created in 20 fresh-frozen human cadaveric humeri. The samples were then randomly divided into two groups of 10 specimens each. Double plate osteosynthesis was performed in both groups. In group A, the two most distal screws of the lateral plate were inserted into the trochlea fragment. In group B, these screws did not extend into the trochlea. Displacement under cyclic loading and ultimate failure loads were determined for all specimens | ||
520 | |a RESULTS: Group A showed significantly less displacement under cyclic loading in each measurement interval (0.92 mm vs. 1.53 mm after 100 cycles, p = 0 0.006; 1.10 mm vs. 1.84 mm after 1000 cycles, p = 0.007; 1.18 mm vs. 1.98 mm after 2000 cycles, p = 0.008). The ultimate failure load was significantly higher in group A than in group B (345.61 ± 120.389 N vs. 238.42 ± 131.61 N, p = 0.037) | ||
520 | |a CONCLUSIONS: Fixation of the trochlea with interdigitating screws in double plate osteosynthesis of low-condylar type C distal humerus fractures results in superior construct stability | ||
520 | |a LEVEL OF EVIDENCE: not applicable (biomechanical) | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Distal humerus | |
650 | 4 | |a Elbow | |
650 | 4 | |a Fracture fixation | |
650 | 4 | |a Humeral fracture | |
650 | 4 | |a Trochlea | |
700 | 1 | |a Siebenlist, Sebastian |e verfasserin |4 aut | |
700 | 1 | |a Leschinger, Tim |e verfasserin |4 aut | |
700 | 1 | |a Kadantsev, Pavel |e verfasserin |4 aut | |
700 | 1 | |a Geyer, Stephanie |e verfasserin |4 aut | |
700 | 1 | |a Wegmann, Kilian |e verfasserin |4 aut | |
700 | 1 | |a Müller, Lars-Peter |e verfasserin |4 aut | |
700 | 1 | |a Hackl, Michael |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Injury |d 1970 |g 55(2024), 4 vom: 15. März, Seite 111486 |w (DE-627)NLM000324183 |x 1879-0267 |7 nnns |
773 | 1 | 8 | |g volume:55 |g year:2024 |g number:4 |g day:15 |g month:03 |g pages:111486 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.injury.2024.111486 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 55 |j 2024 |e 4 |b 15 |c 03 |h 111486 |