Is It Time to Move Beyond TIR to TITR? Real-World Data from Over 20,000 Users of Continuous Glucose Monitoring in Patients with Type 1 and Type 2 Diabetes

The growing use of continuous glucose monitoring (CGM) has been supported by expert consensus and clinical guidelines on glycemic management in diabetes with time in range (TIR 70-180 mg/dL) representing a key CGM-derived glucose metric. Time in tight range (TITR) has also been proposed for clinical use, spanning largely normal glucose levels of 70-140 mg/dL. However, keeping such narrow glucose ranges can be challenging, and understanding the factors modulating TITR can help achieve these tight glycemic targets. Our real-life study aimed to evaluate the relationship between average glucose (AG) and TIR/TITR in a large cohort (n = 22,006) of CGM users, divided into four groups: self-identified as having type 1 diabetes (T1D) treated with insulin using multiple daily injections (MDI) or pumps; type 2 diabetes (T2D) on MDI or insulin pumps; T2D on basal insulin only; and T2D not on insulin treatment. The T2D groups, regardless of treatment type, displayed the highest TIR and TITR values, associated with lowest glycemic variability measured as glucose coefficient of variation (CV; 23-30%). The T1D group showed the lowest TIR and TITR, associated with the highest CVs (36-38%). Overall, higher CV was associated with lower TIR and TITR for AG values below 180 and 140 mg/dL, respectively, with the reverse holding true for AG values above these thresholds. The discordance between AG and TIR/TITR was less pronounced in T2D compared with T1D, attributed to lower CV in the former group. It was also observed that TITR has advantages over TIR for assessing glycemia status and progress toward more stringent A1C, particularly when approaching normal glucose levels. The data detail how CV affects the AG relationship with TIR/TITR, which has implications for CGM interpretation. In many instances TITR, rather than TIR, may be preferable to employ once AG falls below 140 mg/dL and near-normal glucose levels are required clinically.

Medienart:

E-Artikel

Erscheinungsjahr:

2024

Erschienen:

2024

Enthalten in:

Zur Gesamtaufnahme - volume:26

Enthalten in:

Diabetes technology & therapeutics - 26(2024), 3 vom: 31. März, Seite 203-210

Sprache:

Englisch

Beteiligte Personen:

Dunn, Timothy C [VerfasserIn]
Ajjan, Ramzi A [VerfasserIn]
Bergenstal, Richard M [VerfasserIn]
Xu, Yongjin [VerfasserIn]

Links:

Volltext

Themen:

Blood Glucose
Continuous glucose monitoring
Glucose
IY9XDZ35W2
Insulin, Regular, Human
Journal Article
Review
Time in range
Time in tight range

Anmerkungen:

Date Completed 07.03.2024

Date Revised 07.03.2024

published: Print

Citation Status MEDLINE

doi:

10.1089/dia.2023.0565

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM369341465