In this study, we constructed an UV-C illumination chamber using commercially available germicidal lamps and other locally available low-cost components for general-purpose biological decontamination purposes. The illumination chamber provides uniform illumination of around 1 J/cm2 in under 5 min across the chamber. The control mechanism was developed to automate the on/off process and make it more secure minimizing health and other electrical safety. To validate the decontamination efficacy of the UV-C Illumination Chamber we performed the Geobacillus spore strip culture assay. Additionally, we performed the viral load measurement by identifying the COVID-19-specific N-gene and ORF1 gene on surgical masks. The gold standard RT-qPCR measurement was performed to detect and quantify the COVID-19-specific gene on the mask sample. The biochemical assay was conducted on the control and test group to identify the presence of different types of bacteria, and fungi before and after exposure under the illumination chamber. The findings of our study revealed satisfactory decontamination efficacy test results. Therefore, it could be an excellent device in healthcare settings as a disinfection tool for biological decontamination such as SAR-CoV-2 virus, personal protection equipment (PPE), (including n95, k95 respirators, and surgical masks), and other common pathogens.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:10 |
---|---|
Enthalten in: |
Heliyon - 10(2024), 5 vom: 15. März, Seite e26348 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Mohsin, Abu S M [VerfasserIn] |
---|
Links: |
---|
Themen: |
Biological decontamination and pathogens |
---|
Anmerkungen: |
Date Revised 06.03.2024 published: Electronic-eCollection Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1016/j.heliyon.2024.e26348 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM369297067 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM369297067 | ||
003 | DE-627 | ||
005 | 20240306233247.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240305s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.heliyon.2024.e26348 |2 doi | |
028 | 5 | 2 | |a pubmed24n1318.xml |
035 | |a (DE-627)NLM369297067 | ||
035 | |a (NLM)38439842 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Mohsin, Abu S M |e verfasserin |4 aut | |
245 | 1 | 0 | |a Design optimization and validation of UV-C illumination chamber for filtering facepiece respirators |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 06.03.2024 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a © 2024 The Authors. | ||
520 | |a In this study, we constructed an UV-C illumination chamber using commercially available germicidal lamps and other locally available low-cost components for general-purpose biological decontamination purposes. The illumination chamber provides uniform illumination of around 1 J/cm2 in under 5 min across the chamber. The control mechanism was developed to automate the on/off process and make it more secure minimizing health and other electrical safety. To validate the decontamination efficacy of the UV-C Illumination Chamber we performed the Geobacillus spore strip culture assay. Additionally, we performed the viral load measurement by identifying the COVID-19-specific N-gene and ORF1 gene on surgical masks. The gold standard RT-qPCR measurement was performed to detect and quantify the COVID-19-specific gene on the mask sample. The biochemical assay was conducted on the control and test group to identify the presence of different types of bacteria, and fungi before and after exposure under the illumination chamber. The findings of our study revealed satisfactory decontamination efficacy test results. Therefore, it could be an excellent device in healthcare settings as a disinfection tool for biological decontamination such as SAR-CoV-2 virus, personal protection equipment (PPE), (including n95, k95 respirators, and surgical masks), and other common pathogens | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Biological decontamination and pathogens | |
650 | 4 | |a Decontamination efficacy | |
650 | 4 | |a Facepiece respirators | |
650 | 4 | |a Personal protection equipment (PPE) | |
650 | 4 | |a SAR-CoV-2 virus | |
650 | 4 | |a UV-C illumination chamber | |
700 | 1 | |a Jamiruddin, Mohd Raeed |e verfasserin |4 aut | |
700 | 1 | |a Peyal, Md Mahmudul Kabir |e verfasserin |4 aut | |
700 | 1 | |a Sharmin, Shahana |e verfasserin |4 aut | |
700 | 1 | |a Ahmed, Ashfaq |e verfasserin |4 aut | |
700 | 1 | |a Puspita, Afrin Hossain |e verfasserin |4 aut | |
700 | 1 | |a Sharfuddin, A A M |e verfasserin |4 aut | |
700 | 1 | |a Malik, Afrida |e verfasserin |4 aut | |
700 | 1 | |a Hasib, Al |e verfasserin |4 aut | |
700 | 1 | |a Suchona, Sanjida Akter |e verfasserin |4 aut | |
700 | 1 | |a Chowdhury, Arshad M |e verfasserin |4 aut | |
700 | 1 | |a Kabir, Eva Rahman |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Heliyon |d 2015 |g 10(2024), 5 vom: 15. März, Seite e26348 |w (DE-627)NLM255913095 |x 2405-8440 |7 nnns |
773 | 1 | 8 | |g volume:10 |g year:2024 |g number:5 |g day:15 |g month:03 |g pages:e26348 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.heliyon.2024.e26348 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 10 |j 2024 |e 5 |b 15 |c 03 |h e26348 |