Short- to Mid-Term Clinical and Radiological Results of Selective Laser Melting Highly Porous Titanium Cup in Primary Total Hip Arthroplasty
(1) Background: The aim of this study was to evaluate short- to mid-term clinical and radiological results in patients undergoing primary total hip arthroplasty (THA) with the use of a Selective Laser Melting 3D-printed highly porous titanium acetabular cup (Jump System Traser®, Permedica Orthopaedics). (2) Methods: We conducted a retrospective study and collected prospective data on 125 consecutive patients who underwent primary THA with the use of highly porous titanium cup. Each patient was evaluated preoperatively and postoperatively with a clinical and radiological assessment. (3) Results: The final cohort consisted of 104 patients evaluated after a correct value of 52 (38-74) months. The median Harris Hip Score (HHS) significantly improved from 63.7 (16-95.8) preoperatively to 94.8 (38.2-95.8) postoperatively (p < 0.001), with higher improvement associated with higher age at surgery (β = 0.22, p = 0.025). On postoperative radiographs, the average acetabular cup inclination and anteversion were 46° (30°-57°) and 15° (1°-32°), respectively. All cups radiographically showed signs of osseointegration with no radiolucency observed, or component loosening. (4) Conclusions: The use of this highly porous acetabular cup in primary THA achieved excellent clinical, functional, and radiological results at mid-term follow-up. A better clinical recovery can be expected in older patients. The radiological evaluation showed excellent osseointegration of the cup with complete absence of periprosthetic radiolucent lines.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:13 |
---|---|
Enthalten in: |
Journal of clinical medicine - 13(2024), 4 vom: 08. Feb. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Familiari, Filippo [VerfasserIn] |
---|
Links: |
---|
Anmerkungen: |
Date Revised 27.02.2024 published: Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.3390/jcm13040969 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM368882594 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM368882594 | ||
003 | DE-627 | ||
005 | 20240229164702.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240229s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/jcm13040969 |2 doi | |
028 | 5 | 2 | |a pubmed24n1309.xml |
035 | |a (DE-627)NLM368882594 | ||
035 | |a (NLM)38398281 | ||
035 | |a (PII)969 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Familiari, Filippo |e verfasserin |4 aut | |
245 | 1 | 0 | |a Short- to Mid-Term Clinical and Radiological Results of Selective Laser Melting Highly Porous Titanium Cup in Primary Total Hip Arthroplasty |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 27.02.2024 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a (1) Background: The aim of this study was to evaluate short- to mid-term clinical and radiological results in patients undergoing primary total hip arthroplasty (THA) with the use of a Selective Laser Melting 3D-printed highly porous titanium acetabular cup (Jump System Traser®, Permedica Orthopaedics). (2) Methods: We conducted a retrospective study and collected prospective data on 125 consecutive patients who underwent primary THA with the use of highly porous titanium cup. Each patient was evaluated preoperatively and postoperatively with a clinical and radiological assessment. (3) Results: The final cohort consisted of 104 patients evaluated after a correct value of 52 (38-74) months. The median Harris Hip Score (HHS) significantly improved from 63.7 (16-95.8) preoperatively to 94.8 (38.2-95.8) postoperatively (p < 0.001), with higher improvement associated with higher age at surgery (β = 0.22, p = 0.025). On postoperative radiographs, the average acetabular cup inclination and anteversion were 46° (30°-57°) and 15° (1°-32°), respectively. All cups radiographically showed signs of osseointegration with no radiolucency observed, or component loosening. (4) Conclusions: The use of this highly porous acetabular cup in primary THA achieved excellent clinical, functional, and radiological results at mid-term follow-up. A better clinical recovery can be expected in older patients. The radiological evaluation showed excellent osseointegration of the cup with complete absence of periprosthetic radiolucent lines | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Harris hip score (HHS) | |
650 | 4 | |a SLM 3D-printed highly porous titanium acetabular cup | |
650 | 4 | |a bone sclerosis | |
650 | 4 | |a heterotopic ossifications | |
650 | 4 | |a highly porous titanium | |
650 | 4 | |a osseointegration | |
650 | 4 | |a primary total hip arthroplasty | |
650 | 4 | |a radiolucency | |
650 | 4 | |a selective laser melting (SLM) | |
700 | 1 | |a Barone, Alessandro |e verfasserin |4 aut | |
700 | 1 | |a De Gori, Marco |e verfasserin |4 aut | |
700 | 1 | |a Banci, Lorenzo |e verfasserin |4 aut | |
700 | 1 | |a Palco, Michelangelo |e verfasserin |4 aut | |
700 | 1 | |a Simonetta, Roberto |e verfasserin |4 aut | |
700 | 1 | |a Gasparini, Giorgio |e verfasserin |4 aut | |
700 | 1 | |a Mercurio, Michele |e verfasserin |4 aut | |
700 | 1 | |a Calafiore, Giuseppe |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of clinical medicine |d 2012 |g 13(2024), 4 vom: 08. Feb. |w (DE-627)NLM230666310 |x 2077-0383 |7 nnns |
773 | 1 | 8 | |g volume:13 |g year:2024 |g number:4 |g day:08 |g month:02 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/jcm13040969 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 13 |j 2024 |e 4 |b 08 |c 02 |