Liver Magnetic Resonance Elastography : Focus on Methodology, Technique, and Feasibility
Magnetic resonance elastography (MRE) is an imaging technique that combines low-frequency mechanical vibrations with magnetic resonance imaging to create visual maps and quantify liver parenchyma stiffness. As in recent years, diffuse liver diseases have become highly prevalent worldwide and could lead to a chronic condition with different stages of fibrosis. There is a strong necessity for a non-invasive, highly accurate, and standardised quantitative assessment to evaluate and manage patients with different stages of fibrosis from diagnosis to follow-up, as the actual reference standard for the diagnosis and staging of liver fibrosis is biopsy, an invasive method with possible peri-procedural complications and sampling errors. MRE could quantitatively evaluate liver stiffness, as it is a rapid and repeatable method with high specificity and sensitivity. MRE is based on the propagation of mechanical shear waves through the liver tissue that are directly proportional to the organ's stiffness, expressed in kilopascals (kPa). To obtain a valid assessment of the real hepatic stiffness values, it is mandatory to obtain a high-quality examination. To understand the pearls and pitfalls of MRE, in this review, we describe our experience after one year of performing MRE from indications and patient preparation to acquisition, quality control, and image analysis.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:14 |
---|---|
Enthalten in: |
Diagnostics (Basel, Switzerland) - 14(2024), 4 vom: 09. Feb. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Zerunian, Marta [VerfasserIn] |
---|
Links: |
---|
Themen: |
Diffuse liver disease |
---|
Anmerkungen: |
Date Revised 27.02.2024 published: Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.3390/diagnostics14040379 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM368863980 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM368863980 | ||
003 | DE-627 | ||
005 | 20240229164549.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240229s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/diagnostics14040379 |2 doi | |
028 | 5 | 2 | |a pubmed24n1309.xml |
035 | |a (DE-627)NLM368863980 | ||
035 | |a (NLM)38396418 | ||
035 | |a (PII)379 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Zerunian, Marta |e verfasserin |4 aut | |
245 | 1 | 0 | |a Liver Magnetic Resonance Elastography |b Focus on Methodology, Technique, and Feasibility |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 27.02.2024 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Magnetic resonance elastography (MRE) is an imaging technique that combines low-frequency mechanical vibrations with magnetic resonance imaging to create visual maps and quantify liver parenchyma stiffness. As in recent years, diffuse liver diseases have become highly prevalent worldwide and could lead to a chronic condition with different stages of fibrosis. There is a strong necessity for a non-invasive, highly accurate, and standardised quantitative assessment to evaluate and manage patients with different stages of fibrosis from diagnosis to follow-up, as the actual reference standard for the diagnosis and staging of liver fibrosis is biopsy, an invasive method with possible peri-procedural complications and sampling errors. MRE could quantitatively evaluate liver stiffness, as it is a rapid and repeatable method with high specificity and sensitivity. MRE is based on the propagation of mechanical shear waves through the liver tissue that are directly proportional to the organ's stiffness, expressed in kilopascals (kPa). To obtain a valid assessment of the real hepatic stiffness values, it is mandatory to obtain a high-quality examination. To understand the pearls and pitfalls of MRE, in this review, we describe our experience after one year of performing MRE from indications and patient preparation to acquisition, quality control, and image analysis | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Review | |
650 | 4 | |a diffuse liver disease | |
650 | 4 | |a fibrosis | |
650 | 4 | |a imaging biomarker | |
650 | 4 | |a magnetic resonance | |
650 | 4 | |a magnetic resonance elastography | |
700 | 1 | |a Masci, Benedetta |e verfasserin |4 aut | |
700 | 1 | |a Caruso, Damiano |e verfasserin |4 aut | |
700 | 1 | |a Pucciarelli, Francesco |e verfasserin |4 aut | |
700 | 1 | |a Polici, Michela |e verfasserin |4 aut | |
700 | 1 | |a Nardacci, Stefano |e verfasserin |4 aut | |
700 | 1 | |a De Santis, Domenico |e verfasserin |4 aut | |
700 | 1 | |a Iannicelli, Elsa |e verfasserin |4 aut | |
700 | 1 | |a Laghi, Andrea |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Diagnostics (Basel, Switzerland) |d 2011 |g 14(2024), 4 vom: 09. Feb. |w (DE-627)NLM250111136 |x 2075-4418 |7 nnns |
773 | 1 | 8 | |g volume:14 |g year:2024 |g number:4 |g day:09 |g month:02 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/diagnostics14040379 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 14 |j 2024 |e 4 |b 09 |c 02 |