Artificial Multi-Stimulus-Responsive E-Skin Based on an Ionic Film with a Counter-Ion Exchange Reagent
© 2024 Wiley-VCH GmbH..
Sensing pressure and temperature are two important functions of human skin that integrate different types of tactile receptors. In this paper, a deformable artificial flexible multi-stimulus-responsive sensor is demonstrated that can distinguish mechanical pressure from temperature by measuring the impedance and the electrical phase at the same frequency without signal interference. The electrical phase, which is used for measuring the temperature, is totally independent of the pressure by controlling the surface micro-shapes and the ion content of the ionic film. By doping the counter-ion exchange reagent into the ionic liquid before pouring, the upper temperature measuring limit increases from 35 to 50 °C, which is higher than the human body temperature and the ambient temperature on Earth. The sensor shows high sensitivity to pressure (up to 0.495 kPa-1 ) and a wide temperature sensing range (-10 to 50 °C). A multimodal ion-electronic skin (IEM -skin) with an 8 × 8 multi-stimulus-responsive sensor array is fabricated and can successfully sense the distribution of temperature and pressure at the same time. Finally, the sensors are used for monitoring the touching motions of a robot-arm finger controlled by a remote interactive glove and successfully detect the touching states and the temperature changes of different objects.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - year:2024 |
---|---|
Enthalten in: |
Small (Weinheim an der Bergstrasse, Germany) - (2024) vom: 22. Feb., Seite e2310847 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Chen, Baozhong [VerfasserIn] |
---|
Links: |
---|
Themen: |
Counter-ion exchange reagent |
---|
Anmerkungen: |
Date Revised 22.02.2024 published: Print-Electronic Citation Status Publisher |
---|
doi: |
10.1002/smll.202310847 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM368758257 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM368758257 | ||
003 | DE-627 | ||
005 | 20240222233325.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240222s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1002/smll.202310847 |2 doi | |
028 | 5 | 2 | |a pubmed24n1302.xml |
035 | |a (DE-627)NLM368758257 | ||
035 | |a (NLM)38385814 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Chen, Baozhong |e verfasserin |4 aut | |
245 | 1 | 0 | |a Artificial Multi-Stimulus-Responsive E-Skin Based on an Ionic Film with a Counter-Ion Exchange Reagent |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 22.02.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status Publisher | ||
520 | |a © 2024 Wiley-VCH GmbH. | ||
520 | |a Sensing pressure and temperature are two important functions of human skin that integrate different types of tactile receptors. In this paper, a deformable artificial flexible multi-stimulus-responsive sensor is demonstrated that can distinguish mechanical pressure from temperature by measuring the impedance and the electrical phase at the same frequency without signal interference. The electrical phase, which is used for measuring the temperature, is totally independent of the pressure by controlling the surface micro-shapes and the ion content of the ionic film. By doping the counter-ion exchange reagent into the ionic liquid before pouring, the upper temperature measuring limit increases from 35 to 50 °C, which is higher than the human body temperature and the ambient temperature on Earth. The sensor shows high sensitivity to pressure (up to 0.495 kPa-1 ) and a wide temperature sensing range (-10 to 50 °C). A multimodal ion-electronic skin (IEM -skin) with an 8 × 8 multi-stimulus-responsive sensor array is fabricated and can successfully sense the distribution of temperature and pressure at the same time. Finally, the sensors are used for monitoring the touching motions of a robot-arm finger controlled by a remote interactive glove and successfully detect the touching states and the temperature changes of different objects | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a counter-ion exchange reagent | |
650 | 4 | |a e-skin | |
650 | 4 | |a flexible tactile-temperature sensor | |
650 | 4 | |a multi-stimulus-responsive | |
700 | 1 | |a Shen, Kangxin |e verfasserin |4 aut | |
700 | 1 | |a Li, Yaping |e verfasserin |4 aut | |
700 | 1 | |a Huang, Bo |e verfasserin |4 aut | |
700 | 1 | |a Su, Huiming |e verfasserin |4 aut | |
700 | 1 | |a Xu, Jintao |e verfasserin |4 aut | |
700 | 1 | |a Yang, Shuai |e verfasserin |4 aut | |
700 | 1 | |a Zhou, Qi |e verfasserin |4 aut | |
700 | 1 | |a Lan, Linfeng |e verfasserin |4 aut | |
700 | 1 | |a Peng, Junbiao |e verfasserin |4 aut | |
700 | 1 | |a Cao, Yong |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Small (Weinheim an der Bergstrasse, Germany) |d 2005 |g (2024) vom: 22. Feb., Seite e2310847 |w (DE-627)NLM167400452 |x 1613-6829 |7 nnns |
773 | 1 | 8 | |g year:2024 |g day:22 |g month:02 |g pages:e2310847 |
856 | 4 | 0 | |u http://dx.doi.org/10.1002/smll.202310847 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |j 2024 |b 22 |c 02 |h e2310847 |