Fixation of Proximal flange of Lumen Apposing Metal Stent using Through-the-Scope Endoscopic Suturing System to Prevent Stent Migration in Single-Session EUS-directed Transgastric ERCP : A Pilot Study
Copyright © 2024 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved..
BACKGROUND AND AIMS: With the global obesity pandemic, clinical scenarios requiring urgent ERCP in patients with gastric bypass surgery are on the rise and Single-Session Endoscopic Ultrasound-Directed Transgastric Endoscopic Retrograde Cholangiopancreatography (SS-EDGE) can effectively address these technical challenges. The aim of this study was to evaluate and describe safe and effective use of through-the-scope endoscopic suturing system for anchoring the lumen apposing metal stents (LAMS) during SS-EDGE.
METHODS: Six patients with Roux-en-Y gastric bypass (RYGB) underwent SS-EDGE at our center. Through-the-scope endoscopic suturing system was used for anchoring the lumen apposing metal stents (LAMS) during SS-EDGE.
RESULTS: Clinical and technical success was achieved in all six patients without any adverse events related to the procedure. No stent migration, pneumoperitoneum or gastrointestinal perforation noted. Upon 4 weeks follow-up, no stent migration was noted with Through-the-scope suturing system remained anchored. LAMS along with tacks were removed and gastric fistulae were successfully closed endoscopically in all patients to prevent weight gain.
CONCLUSION: Use of through-the-scope endoscopic suturing can be a safe, reliable, and potentially cost-effective novel technique for LAMS fixation to successfully perform SS-EDGE in RYGB patients.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - year:2024 |
---|---|
Enthalten in: |
Gastrointestinal endoscopy - (2024) vom: 19. Feb. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Khan, Hafiz Muzaffar Akbar [VerfasserIn] |
---|
Links: |
---|
Themen: |
Journal Article |
---|
Anmerkungen: |
Date Revised 21.02.2024 published: Print-Electronic Citation Status Publisher |
---|
doi: |
10.1016/j.gie.2024.02.013 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM368728943 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM368728943 | ||
003 | DE-627 | ||
005 | 20240222233037.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240222s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.gie.2024.02.013 |2 doi | |
028 | 5 | 2 | |a pubmed24n1302.xml |
035 | |a (DE-627)NLM368728943 | ||
035 | |a (NLM)38382885 | ||
035 | |a (PII)S0016-5107(24)00110-X | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Khan, Hafiz Muzaffar Akbar |e verfasserin |4 aut | |
245 | 1 | 0 | |a Fixation of Proximal flange of Lumen Apposing Metal Stent using Through-the-Scope Endoscopic Suturing System to Prevent Stent Migration in Single-Session EUS-directed Transgastric ERCP |b A Pilot Study |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 21.02.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status Publisher | ||
520 | |a Copyright © 2024 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved. | ||
520 | |a BACKGROUND AND AIMS: With the global obesity pandemic, clinical scenarios requiring urgent ERCP in patients with gastric bypass surgery are on the rise and Single-Session Endoscopic Ultrasound-Directed Transgastric Endoscopic Retrograde Cholangiopancreatography (SS-EDGE) can effectively address these technical challenges. The aim of this study was to evaluate and describe safe and effective use of through-the-scope endoscopic suturing system for anchoring the lumen apposing metal stents (LAMS) during SS-EDGE | ||
520 | |a METHODS: Six patients with Roux-en-Y gastric bypass (RYGB) underwent SS-EDGE at our center. Through-the-scope endoscopic suturing system was used for anchoring the lumen apposing metal stents (LAMS) during SS-EDGE | ||
520 | |a RESULTS: Clinical and technical success was achieved in all six patients without any adverse events related to the procedure. No stent migration, pneumoperitoneum or gastrointestinal perforation noted. Upon 4 weeks follow-up, no stent migration was noted with Through-the-scope suturing system remained anchored. LAMS along with tacks were removed and gastric fistulae were successfully closed endoscopically in all patients to prevent weight gain | ||
520 | |a CONCLUSION: Use of through-the-scope endoscopic suturing can be a safe, reliable, and potentially cost-effective novel technique for LAMS fixation to successfully perform SS-EDGE in RYGB patients | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Roux-en-Y gastric bypass (RYGB) | |
650 | 4 | |a Through-the-scope endoscopic suturing system | |
650 | 4 | |a single-session EUS-directed transgastric ERCP (EDGE) | |
700 | 1 | |a Hussain, Azhar |e verfasserin |4 aut | |
700 | 1 | |a Kumar, Vishnu Charan Suresh |e verfasserin |4 aut | |
700 | 1 | |a Yang, Dennis |e verfasserin |4 aut | |
700 | 1 | |a Hasan, Muhammad Khalid |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Gastrointestinal endoscopy |d 1965 |g (2024) vom: 19. Feb. |w (DE-627)NLM000030139 |x 1097-6779 |7 nnns |
773 | 1 | 8 | |g year:2024 |g day:19 |g month:02 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.gie.2024.02.013 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |j 2024 |b 19 |c 02 |