Turning Antibodies into Ratiometric Bioluminescent Sensors for Competition-Based Homogeneous Immunoassays
Here we present LUCOS (Luminescent Competition Sensor), a modular and broadly applicable bioluminescent diagnostic platform enabling the detection of both small molecules and protein biomarkers. The construction of LUCOS sensors entails the covalent and site-specific coupling of a bioluminescent sensor component to an analyte-specific antibody via protein G-mediated photoconjugation. Target detection is accomplished through intramolecular competition with a tethered analyte competitor for antibody binding. We established two variants of LUCOS: an inherent ratiometric LUCOSR variant and an intensiometric LUCOSI version, which can be used for ratiometric detection upon the addition of a split calibrator luciferase. To demonstrate the versatility of the LUCOS platform, sensors were developed for the detection of the small molecule cortisol and the protein biomarker NT-proBNP. Sensors for both targets displayed analyte-dependent changes in the emission ratio and enabled detection in the micromolar concentration range (KD,app = 16-92 μM). Furthermore, we showed that the response range of the LUCOS sensor can be adjusted by attenuating the affinity of the tethered NT-proBNP competitor, which enabled detection in the nanomolar concentration range (KD,app = 317 ± 26 nM). Overall, the LUCOS platform offers a highly versatile and easy method to convert commercially available monoclonal antibodies into bioluminescent biosensors that provide a homogeneous alternative for the competitive immunoassay.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:9 |
---|---|
Enthalten in: |
ACS sensors - 9(2024), 3 vom: 22. März, Seite 1401-1409 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
van Aalen, Eva A [VerfasserIn] |
---|
Links: |
---|
Themen: |
Antibodies |
---|
Anmerkungen: |
Date Completed 25.03.2024 Date Revised 28.03.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1021/acssensors.3c02478 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM368706486 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM368706486 | ||
003 | DE-627 | ||
005 | 20240329000550.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240222s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1021/acssensors.3c02478 |2 doi | |
028 | 5 | 2 | |a pubmed24n1353.xml |
035 | |a (DE-627)NLM368706486 | ||
035 | |a (NLM)38380622 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a van Aalen, Eva A |e verfasserin |4 aut | |
245 | 1 | 0 | |a Turning Antibodies into Ratiometric Bioluminescent Sensors for Competition-Based Homogeneous Immunoassays |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 25.03.2024 | ||
500 | |a Date Revised 28.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Here we present LUCOS (Luminescent Competition Sensor), a modular and broadly applicable bioluminescent diagnostic platform enabling the detection of both small molecules and protein biomarkers. The construction of LUCOS sensors entails the covalent and site-specific coupling of a bioluminescent sensor component to an analyte-specific antibody via protein G-mediated photoconjugation. Target detection is accomplished through intramolecular competition with a tethered analyte competitor for antibody binding. We established two variants of LUCOS: an inherent ratiometric LUCOSR variant and an intensiometric LUCOSI version, which can be used for ratiometric detection upon the addition of a split calibrator luciferase. To demonstrate the versatility of the LUCOS platform, sensors were developed for the detection of the small molecule cortisol and the protein biomarker NT-proBNP. Sensors for both targets displayed analyte-dependent changes in the emission ratio and enabled detection in the micromolar concentration range (KD,app = 16-92 μM). Furthermore, we showed that the response range of the LUCOS sensor can be adjusted by attenuating the affinity of the tethered NT-proBNP competitor, which enabled detection in the nanomolar concentration range (KD,app = 317 ± 26 nM). Overall, the LUCOS platform offers a highly versatile and easy method to convert commercially available monoclonal antibodies into bioluminescent biosensors that provide a homogeneous alternative for the competitive immunoassay | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a BRET | |
650 | 4 | |a antibodies | |
650 | 4 | |a biosensors | |
650 | 4 | |a competition assay | |
650 | 4 | |a homogeneous immunoassay | |
650 | 4 | |a small molecules | |
650 | 7 | |a Antibodies, Monoclonal |2 NLM | |
650 | 7 | |a Luciferases |2 NLM | |
650 | 7 | |a EC 1.13.12.- |2 NLM | |
700 | 1 | |a Lurvink, Joep J J |e verfasserin |4 aut | |
700 | 1 | |a Vermeulen, Leandra |e verfasserin |4 aut | |
700 | 1 | |a van Gerven, Benice |e verfasserin |4 aut | |
700 | 1 | |a Ni, Yan |e verfasserin |4 aut | |
700 | 1 | |a Arts, Remco |e verfasserin |4 aut | |
700 | 1 | |a Merkx, Maarten |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t ACS sensors |d 2016 |g 9(2024), 3 vom: 22. März, Seite 1401-1409 |w (DE-627)NLM257485090 |x 2379-3694 |7 nnns |
773 | 1 | 8 | |g volume:9 |g year:2024 |g number:3 |g day:22 |g month:03 |g pages:1401-1409 |
856 | 4 | 0 | |u http://dx.doi.org/10.1021/acssensors.3c02478 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 9 |j 2024 |e 3 |b 22 |c 03 |h 1401-1409 |