Transvaginal Sonography for the Preoperative Assessment of Parametrial Deep Infiltrating Endometriosis : A Diagnostic Accuracy Study

© 2024 S. Karger AG, Basel..

OBJECTIVE: The aim of the study was to evaluate the diagnostic accuracy for parametria endometriosis (PE) of transvaginal sonography (TVS) performed following a systematic approach for the assessment of the lateral parametria.

DESIGN: A diagnostic accuracy study was employed based on a prospective observational design.

PARTICIPANTS: All consecutive patients who underwent laparoscopic surgery for endometriosis between January 2016 and December 2020 were considered.

SETTING: The study was conducted at endometriosis referral hospitals.

METHODS: We prospectively collected clinical, imaging, and surgical data of all consecutive patients who underwent laparoscopic surgery for endometriosis between January 2016 and December 2020. A standardized technique with a systematic approach for the assessment of the lateral parametria following specific anatomic landmarks was used for the TVS. The diagnostic accuracy for PE in TVS was assessed using the intraoperative and pathologic diagnosis of PE as the gold standard.

RESULTS: In 476 patients who underwent surgery, PE was identified in 114 out of 476 patients (23.95%): 91 left and 54 right PE out of 476 surgical procedures were identified (19.12% vs. 11.34%; p = 0.001); bilateral involvement in 27.19% (31/114 patients) cases. The sensitivity of TVS for PE was 90.74% (79.70-96.92%, 95% CI) for the right side and 87.91% (79.40-93.81%, 95% CI) for the left side. The specificity was almost identical for both sides (98.58% vs. 98.18%). For the right parametrium, the positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 63.82 (28.70-141.90, 95% CI) and 0.09 (0.04-0.22, 95% CI), respectively. On the left parametrium, the PLR and NLR were 48.35 (23.12-101.4, 95% CI) and 0.12 (0.07-0.21, 95% CI), respectively. The diagnostic accuracy for right and left PE was 97.69% (95.90-98.84%, 95% CI) and 96.22% (94.04-97.74%, 95% CI), respectively.

LIMITATIONS: The principal limit is the high dependence of TVS on the operator experience. Therefore, although a standardized approach following precise definitions of anatomical landmarks was used, we cannot conclude that the observed accuracy of TVS for PE is the same for all sonographers. In this regard, the learning curve was not assessed. In the case of negative TVS for parametrial involvement with an absent intraoperative suspect, a complete dissection of the parametrium was not performed to avoid surgical complications; therefore, cases of minor PE may be missed, underestimating false negatives.

CONCLUSIONS: TVS performed following a systematic approach for assessing the lateral parametria seems to have good diagnostic accuracy for PE with large changes in the posttest probability of parametrial involvement based on the TVS evaluation. Considering the clinical and surgical implications of PE, further studies implementing a standardized approach for assessing the parametrium by TVS are recommended to confirm our observations and implement a standardized protocol in clinical practice.

Medienart:

E-Artikel

Erscheinungsjahr:

2024

Erschienen:

2024

Enthalten in:

Zur Gesamtaufnahme - volume:89

Enthalten in:

Gynecologic and obstetric investigation - 89(2024), 2 vom: 20., Seite 111-119

Sprache:

Englisch

Beteiligte Personen:

Garzon, Simone [VerfasserIn]
Laganà, Antonio Simone [VerfasserIn]
Guerriero, Stefano [VerfasserIn]
Alcázar, Juan Luis [VerfasserIn]
Dababou, Susan [VerfasserIn]
Uccella, Stefano [VerfasserIn]
Scioscia, Marco [VerfasserIn]

Links:

Volltext

Themen:

Deep infiltrating endometriosis
Diagnostic accuracy
Journal Article
Observational Study
Parametrial endometriosis
Transvaginal sonography

Anmerkungen:

Date Completed 15.04.2024

Date Revised 15.04.2024

published: Print-Electronic

Citation Status MEDLINE

doi:

10.1159/000535940

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM368679993