Steel drills versus zirconia drills on heat generation at the surgical site of dental implants : A systematic review and meta-analysis
© 2023 THE AUTHORS..
Objective: The aim was to evaluate the difference in the heat generated between zirconia (Zr) and steel (SS) drills, during implant site preparation.
Material and methods: This systematic review followed the PRISMA methodology criteria and used the JBI Critical Assessment Guidelines for Quasi-Experimental Studies for quality assessment. The electronic search was conducted by using the PubMed/MEDLINE, Embase, and Cochrane Library databases to January 2023. The formulated population, intervention, comparison, outcome (PICO) question was "Do zirconia drills generate less heat than steel drills during implant site preparation?". The meta-analysis was based on an inverse variance (IV) method.
Results: This review included 10 studies in vitro that used zirconia drills compared to steel drills with or without coatings. The meta-analysis indicated a significant difference between Zr drills and SS drills, with a lower bone temperature variation with Zr drills.
Conclusions: Despite the limitations of this review, it was concluded that Zr drills had significantly less temperature variation than SS drills.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:36 |
---|---|
Enthalten in: |
The Saudi dental journal - 36(2024), 1 vom: 13. Jan., Seite 1-10 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Augusto Alves Bento, Victor [VerfasserIn] |
---|
Links: |
---|
Themen: |
Ceramics |
---|
Anmerkungen: |
Date Revised 21.02.2024 published: Print-Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1016/j.sdentj.2023.09.001 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM368654362 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM368654362 | ||
003 | DE-627 | ||
005 | 20240222092119.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240220s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.sdentj.2023.09.001 |2 doi | |
028 | 5 | 2 | |a pubmed24n1301.xml |
035 | |a (DE-627)NLM368654362 | ||
035 | |a (NLM)38375375 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Augusto Alves Bento, Victor |e verfasserin |4 aut | |
245 | 1 | 0 | |a Steel drills versus zirconia drills on heat generation at the surgical site of dental implants |b A systematic review and meta-analysis |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 21.02.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a © 2023 THE AUTHORS. | ||
520 | |a Objective: The aim was to evaluate the difference in the heat generated between zirconia (Zr) and steel (SS) drills, during implant site preparation | ||
520 | |a Material and methods: This systematic review followed the PRISMA methodology criteria and used the JBI Critical Assessment Guidelines for Quasi-Experimental Studies for quality assessment. The electronic search was conducted by using the PubMed/MEDLINE, Embase, and Cochrane Library databases to January 2023. The formulated population, intervention, comparison, outcome (PICO) question was "Do zirconia drills generate less heat than steel drills during implant site preparation?". The meta-analysis was based on an inverse variance (IV) method | ||
520 | |a Results: This review included 10 studies in vitro that used zirconia drills compared to steel drills with or without coatings. The meta-analysis indicated a significant difference between Zr drills and SS drills, with a lower bone temperature variation with Zr drills | ||
520 | |a Conclusions: Despite the limitations of this review, it was concluded that Zr drills had significantly less temperature variation than SS drills | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Review | |
650 | 4 | |a Ceramics | |
650 | 4 | |a Dental Implants | |
650 | 4 | |a Hot Temperature | |
650 | 4 | |a Osteotomy | |
650 | 4 | |a Stainless Steel | |
700 | 1 | |a Marcela de Luna Gomes, Jessica |e verfasserin |4 aut | |
700 | 1 | |a Davi Del Rei Daltro Rosa, Cleber |e verfasserin |4 aut | |
700 | 1 | |a Pedro Justino de Oliveira Limirio, João |e verfasserin |4 aut | |
700 | 1 | |a Micheline Dos Santos, Daniela |e verfasserin |4 aut | |
700 | 1 | |a Coelho Goiato, Marcelo |e verfasserin |4 aut | |
700 | 1 | |a Piza Pellizzer, Eduardo |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t The Saudi dental journal |d 1997 |g 36(2024), 1 vom: 13. Jan., Seite 1-10 |w (DE-627)NLM092652042 |x 1013-9052 |7 nnns |
773 | 1 | 8 | |g volume:36 |g year:2024 |g number:1 |g day:13 |g month:01 |g pages:1-10 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.sdentj.2023.09.001 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 36 |j 2024 |e 1 |b 13 |c 01 |h 1-10 |