The value of quantitative contrast-enhanced ultrasonography analysis in evaluating central retinal artery microcirculation in patients with diabetes mellitus : comparison with colour Doppler imaging
Copyright © 2024 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved..
AIM: To compare the efficacy of quantitative contrast-enhanced ultrasonography (CEUS) analysis and colour Doppler ultrasound (CDU) in evaluating central retinal artery (CRA) microcirculation in patients with diabetes mellitus (DM).
MATERIALS AND METHODS: In this prospective study, a total of 55 patients (98 eyes) with DM were enrolled as the study group. They were compared to 46 age-matched healthy volunteers (92 eyes) who were selected as the control group. Each patient underwent CDU and subsequent CEUS examination. CDU and quantitative CEUS parameters were evaluated. The diagnostic efficiency of the diagnostic performance of CEUS and CDU was evaluated and compared, and the scale thresholds of predictive indicators for the diagnosis of proliferative diabetic retinopathy (PDR) were evaluated using receiver operating characteristics (ROC) curve analyses.
RESULTS: Group pairwise comparisons showed that the end diastolic velocity (EDV) and arrival time (AT) of CRA were significant predictors for PDR by CDU and by quantitative CEUS analysis, respectively (all p<0.05). The ROC curve analysis showed that the area under the curve value of AT was significantly higher than that of EDV (0.875 versus 0.634, p=0.0002). Accordingly, an AT cut-off value of 1.07 seconds resulted a sensitivity of 90.62 % and a specificity of 79.31 %.
CONCLUSION: Quantitative CEUS analysis can improve the accuracy of clinical staging of diabetic retinopathy for the patients with DM, and the AT showed the best diagnostic efficiency.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:79 |
---|---|
Enthalten in: |
Clinical radiology - 79(2024), 4 vom: 30. März, Seite e560-e566 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Xu, Y [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Completed 11.03.2024 Date Revised 11.03.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.1016/j.crad.2024.01.011 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM368260267 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM368260267 | ||
003 | DE-627 | ||
005 | 20240311232253.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240210s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.crad.2024.01.011 |2 doi | |
028 | 5 | 2 | |a pubmed24n1323.xml |
035 | |a (DE-627)NLM368260267 | ||
035 | |a (NLM)38336532 | ||
035 | |a (PII)S0009-9260(24)00032-1 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Xu, Y |e verfasserin |4 aut | |
245 | 1 | 4 | |a The value of quantitative contrast-enhanced ultrasonography analysis in evaluating central retinal artery microcirculation in patients with diabetes mellitus |b comparison with colour Doppler imaging |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 11.03.2024 | ||
500 | |a Date Revised 11.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a Copyright © 2024 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved. | ||
520 | |a AIM: To compare the efficacy of quantitative contrast-enhanced ultrasonography (CEUS) analysis and colour Doppler ultrasound (CDU) in evaluating central retinal artery (CRA) microcirculation in patients with diabetes mellitus (DM) | ||
520 | |a MATERIALS AND METHODS: In this prospective study, a total of 55 patients (98 eyes) with DM were enrolled as the study group. They were compared to 46 age-matched healthy volunteers (92 eyes) who were selected as the control group. Each patient underwent CDU and subsequent CEUS examination. CDU and quantitative CEUS parameters were evaluated. The diagnostic efficiency of the diagnostic performance of CEUS and CDU was evaluated and compared, and the scale thresholds of predictive indicators for the diagnosis of proliferative diabetic retinopathy (PDR) were evaluated using receiver operating characteristics (ROC) curve analyses | ||
520 | |a RESULTS: Group pairwise comparisons showed that the end diastolic velocity (EDV) and arrival time (AT) of CRA were significant predictors for PDR by CDU and by quantitative CEUS analysis, respectively (all p<0.05). The ROC curve analysis showed that the area under the curve value of AT was significantly higher than that of EDV (0.875 versus 0.634, p=0.0002). Accordingly, an AT cut-off value of 1.07 seconds resulted a sensitivity of 90.62 % and a specificity of 79.31 % | ||
520 | |a CONCLUSION: Quantitative CEUS analysis can improve the accuracy of clinical staging of diabetic retinopathy for the patients with DM, and the AT showed the best diagnostic efficiency | ||
650 | 4 | |a Journal Article | |
650 | 7 | |a Contrast Media |2 NLM | |
700 | 1 | |a Zhu, X Y |e verfasserin |4 aut | |
700 | 1 | |a Feng, H |e verfasserin |4 aut | |
700 | 1 | |a Yu, X P |e verfasserin |4 aut | |
700 | 1 | |a Wang, Y |e verfasserin |4 aut | |
700 | 1 | |a Rong, X |e verfasserin |4 aut | |
700 | 1 | |a Qi, T Y |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Clinical radiology |d 1960 |g 79(2024), 4 vom: 30. März, Seite e560-e566 |w (DE-627)NLM000049220 |x 1365-229X |7 nnns |
773 | 1 | 8 | |g volume:79 |g year:2024 |g number:4 |g day:30 |g month:03 |g pages:e560-e566 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.crad.2024.01.011 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 79 |j 2024 |e 4 |b 30 |c 03 |h e560-e566 |