Relationship Between Increased Oxygen Uptake and Lactate Production With Progressive Incremental Electrode Skeletal Muscle Stimulation : A Pilot Study
Copyright © 2024, Tamura et al..
Background Belt electrode skeletal muscle stimulation (B-SES) is an alternative exercise therapy for those with difficulty performing voluntary exercise. However, it is unknown whether oxygen uptake (VO2) in B-SES is comparable to cardiopulmonary exercise test (CPX) as assessed by voluntary exercise. This study aimed to evaluate oxygen uptake (VO2) and lactate (LA) production in incremental B-SES compared to ergometer CPX and to determine the relationship with ergometer CPX. Methods This study included 10 healthy young Japanese participants. Using a crossover design, all participants underwent incremental B-SES CPX and ergometer CPX using a 20 W ramp. Serum lactic acid concentration (LA) was measured serially before, during, and after B-SES. The tolerability of B-SES was adjusted with the change in LA level (⊿LA). Results Peak VO2 during B-SES (14.1±3.3 mL/kg/min) was significantly lower than ergometer peak VO2 (30.2±6.2 mL/kg/min, P<0.001). B-SES peak VO2 was similar to the anaerobic threshold (AT) VO2 on ergometer CPX (15.1±2.6 mL/kg/min). LA (Rest: 1.4±0.3, Peak: 2.8±0.8 mmol) and plasma noradrenalin (Rest: 0.2±0.1, Peak: 0.4±0.1 ng/mL) levels increased after B-SES. No significant correlation was observed between B-SES peak VO2 and ergometer CPX. However, after adjusting for B-SES, tolerability, it (peak VO2 of B-SES /⊿LA) correlated with peak VO2 (r=0.688, p=0.028) on the ergometer. Conclusion Peak VO2 of the passively progressive B-SES almost reached the AT value of the ergometer CPX without adverse events. Peak VO2 of B-SES adjusted with ⊿LA may be used to predict peak VO2 in ergometer CPX.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:16 |
---|---|
Enthalten in: |
Cureus - 16(2024), 1 vom: 13. Jan., Seite e51919 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Tamura, Yuma [VerfasserIn] |
---|
Links: |
---|
Themen: |
Belt-like electrode skeletal muscle stimulation |
---|
Anmerkungen: |
Date Revised 10.02.2024 published: Electronic-eCollection Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.7759/cureus.51919 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM368229823 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM368229823 | ||
003 | DE-627 | ||
005 | 20240210233404.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240209s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.7759/cureus.51919 |2 doi | |
028 | 5 | 2 | |a pubmed24n1287.xml |
035 | |a (DE-627)NLM368229823 | ||
035 | |a (NLM)38333497 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Tamura, Yuma |e verfasserin |4 aut | |
245 | 1 | 0 | |a Relationship Between Increased Oxygen Uptake and Lactate Production With Progressive Incremental Electrode Skeletal Muscle Stimulation |b A Pilot Study |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 10.02.2024 | ||
500 | |a published: Electronic-eCollection | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Copyright © 2024, Tamura et al. | ||
520 | |a Background Belt electrode skeletal muscle stimulation (B-SES) is an alternative exercise therapy for those with difficulty performing voluntary exercise. However, it is unknown whether oxygen uptake (VO2) in B-SES is comparable to cardiopulmonary exercise test (CPX) as assessed by voluntary exercise. This study aimed to evaluate oxygen uptake (VO2) and lactate (LA) production in incremental B-SES compared to ergometer CPX and to determine the relationship with ergometer CPX. Methods This study included 10 healthy young Japanese participants. Using a crossover design, all participants underwent incremental B-SES CPX and ergometer CPX using a 20 W ramp. Serum lactic acid concentration (LA) was measured serially before, during, and after B-SES. The tolerability of B-SES was adjusted with the change in LA level (⊿LA). Results Peak VO2 during B-SES (14.1±3.3 mL/kg/min) was significantly lower than ergometer peak VO2 (30.2±6.2 mL/kg/min, P<0.001). B-SES peak VO2 was similar to the anaerobic threshold (AT) VO2 on ergometer CPX (15.1±2.6 mL/kg/min). LA (Rest: 1.4±0.3, Peak: 2.8±0.8 mmol) and plasma noradrenalin (Rest: 0.2±0.1, Peak: 0.4±0.1 ng/mL) levels increased after B-SES. No significant correlation was observed between B-SES peak VO2 and ergometer CPX. However, after adjusting for B-SES, tolerability, it (peak VO2 of B-SES /⊿LA) correlated with peak VO2 (r=0.688, p=0.028) on the ergometer. Conclusion Peak VO2 of the passively progressive B-SES almost reached the AT value of the ergometer CPX without adverse events. Peak VO2 of B-SES adjusted with ⊿LA may be used to predict peak VO2 in ergometer CPX | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a belt-like electrode skeletal muscle stimulation | |
650 | 4 | |a cardiopulmonary exercise test | |
650 | 4 | |a electric skeletal muscle stimulation | |
650 | 4 | |a exercise tolerance | |
650 | 4 | |a lactic acid | |
650 | 4 | |a peak oxygen uptake | |
700 | 1 | |a Ochiai, Kaori |e verfasserin |4 aut | |
700 | 1 | |a Takahashi, Momo |e verfasserin |4 aut | |
700 | 1 | |a Takahashi, Harunori |e verfasserin |4 aut | |
700 | 1 | |a Tomoe, Takashi |e verfasserin |4 aut | |
700 | 1 | |a Sugiyama, Takushi |e verfasserin |4 aut | |
700 | 1 | |a Otani, Naoyuki |e verfasserin |4 aut | |
700 | 1 | |a Sugimura, Hiroyuki |e verfasserin |4 aut | |
700 | 1 | |a Toyoda, Shigeru |e verfasserin |4 aut | |
700 | 1 | |a Yasu, Takanori |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Cureus |d 2013 |g 16(2024), 1 vom: 13. Jan., Seite e51919 |w (DE-627)NLM24118083X |x 2168-8184 |7 nnns |
773 | 1 | 8 | |g volume:16 |g year:2024 |g number:1 |g day:13 |g month:01 |g pages:e51919 |
856 | 4 | 0 | |u http://dx.doi.org/10.7759/cureus.51919 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 16 |j 2024 |e 1 |b 13 |c 01 |h e51919 |