Ion Optical Optimization Method for an Ultrahigh Resolution Planar Multireflection Time-of-Flight Mass Analyzer Using the Hill Climbing Algorithm
A novel ion optical optimization method for planar multireflection time-of-flight mass spectrometry (MR-TOFMS) is introduced in this paper. The multiparameters of the gridless mirror model, including geometric and voltage parameters, are automatically optimized using a self-made program created in SIMION 8.1. Combining with the hill climbing algorithm and parallel computing technique, this method substantially enhances optimization efficiency and accuracy. The fitting results demonstrated that the ion optical performance of the gridless mirror reached up to fourth-order isochronicity with respect to the energy spread and third-order isochronicity with respect to the spatial and angular spread. As a result, the gridless mirror model achieved an aberration limit resolution of 1.7 million under realistic ion beam conditions. Due to constraints of periodic lenses, the aberration limit resolution of the planar MR-TOFMS was optimized to 600k. These results indicate that the hill climbing algorithm is an effective method to search the optimal solutions in complex ion optical systems.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:35 |
---|---|
Enthalten in: |
Journal of the American Society for Mass Spectrometry - 35(2024), 3 vom: 06. März, Seite 575-581 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Chen, Yi [VerfasserIn] |
---|
Links: |
---|
Themen: |
---|
Anmerkungen: |
Date Revised 06.03.2024 published: Print-Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.1021/jasms.3c00417 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM368107876 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM368107876 | ||
003 | DE-627 | ||
005 | 20240306232837.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240207s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1021/jasms.3c00417 |2 doi | |
028 | 5 | 2 | |a pubmed24n1318.xml |
035 | |a (DE-627)NLM368107876 | ||
035 | |a (NLM)38321587 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Chen, Yi |e verfasserin |4 aut | |
245 | 1 | 0 | |a Ion Optical Optimization Method for an Ultrahigh Resolution Planar Multireflection Time-of-Flight Mass Analyzer Using the Hill Climbing Algorithm |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 06.03.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a A novel ion optical optimization method for planar multireflection time-of-flight mass spectrometry (MR-TOFMS) is introduced in this paper. The multiparameters of the gridless mirror model, including geometric and voltage parameters, are automatically optimized using a self-made program created in SIMION 8.1. Combining with the hill climbing algorithm and parallel computing technique, this method substantially enhances optimization efficiency and accuracy. The fitting results demonstrated that the ion optical performance of the gridless mirror reached up to fourth-order isochronicity with respect to the energy spread and third-order isochronicity with respect to the spatial and angular spread. As a result, the gridless mirror model achieved an aberration limit resolution of 1.7 million under realistic ion beam conditions. Due to constraints of periodic lenses, the aberration limit resolution of the planar MR-TOFMS was optimized to 600k. These results indicate that the hill climbing algorithm is an effective method to search the optimal solutions in complex ion optical systems | ||
650 | 4 | |a Journal Article | |
700 | 1 | |a Chen, Ping |e verfasserin |4 aut | |
700 | 1 | |a Cao, Yixue |e verfasserin |4 aut | |
700 | 1 | |a Hua, Lei |e verfasserin |4 aut | |
700 | 1 | |a Li, Haiyang |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of the American Society for Mass Spectrometry |d 1990 |g 35(2024), 3 vom: 06. März, Seite 575-581 |w (DE-627)NLM089758196 |x 1879-1123 |7 nnns |
773 | 1 | 8 | |g volume:35 |g year:2024 |g number:3 |g day:06 |g month:03 |g pages:575-581 |
856 | 4 | 0 | |u http://dx.doi.org/10.1021/jasms.3c00417 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 35 |j 2024 |e 3 |b 06 |c 03 |h 575-581 |