The learning curve for using intestinal ultrasonography
Copyright © 2024. Published by Elsevier Ltd..
BACKGROUND AND AIMS: Intestinal ultrasonography (IUS) is challenging to learn. This prospective study examined how the accuracy of IUS increases with operator experience ("learning curve") and if prior abdominal ultrasound experience facilitates the learning process.
METHODS: The study included two trainees with limited abdominal ultrasound experience (< 50 exams) and two with extensive experience (> 500 exams). Each trainee performed 99 examinations and reported four IUS findings. An expert sonographer repeated the exam, and concordance (k) between the expert and trainees was assessed in three consecutive testing periods of 33 exams each.
RESULTS: A progressive improvement in concordance was observed for all IUS findings from Period 1 to Period 3, overall and for both groups of trainees, although those with experience in abdominal ultrasound had faster learning curves. The minimum number of examinations required to achieve concordance with the expert operator for detecting increased bowel wall thickness was 84 and detecting bowel dilatation was 79. However, a minimum of 97 examinations was necessary to achieve concordance for detecting intra-abdominal complications, considered an advanced IUS competence.
CONCLUSION: Basic competence in IUS can be acquired with relatively few examinations, while advanced competence requires more extensive training, particularly for gastroenterologists without abdominal ultrasound experience.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - year:2024 |
---|---|
Enthalten in: |
Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver - (2024) vom: 05. Feb. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Bezzio, Cristina [VerfasserIn] |
---|
Links: |
---|
Themen: |
Bowel ultrasound |
---|
Anmerkungen: |
Date Revised 06.02.2024 published: Print-Electronic Citation Status Publisher |
---|
doi: |
10.1016/j.dld.2024.01.192 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM368101150 |
---|
LEADER | 01000naa a22002652 4500 | ||
---|---|---|---|
001 | NLM368101150 | ||
003 | DE-627 | ||
005 | 20240207232410.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240207s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.dld.2024.01.192 |2 doi | |
028 | 5 | 2 | |a pubmed24n1283.xml |
035 | |a (DE-627)NLM368101150 | ||
035 | |a (NLM)38320914 | ||
035 | |a (PII)S1590-8658(24)00222-6 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Bezzio, Cristina |e verfasserin |4 aut | |
245 | 1 | 4 | |a The learning curve for using intestinal ultrasonography |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 06.02.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status Publisher | ||
520 | |a Copyright © 2024. Published by Elsevier Ltd. | ||
520 | |a BACKGROUND AND AIMS: Intestinal ultrasonography (IUS) is challenging to learn. This prospective study examined how the accuracy of IUS increases with operator experience ("learning curve") and if prior abdominal ultrasound experience facilitates the learning process | ||
520 | |a METHODS: The study included two trainees with limited abdominal ultrasound experience (< 50 exams) and two with extensive experience (> 500 exams). Each trainee performed 99 examinations and reported four IUS findings. An expert sonographer repeated the exam, and concordance (k) between the expert and trainees was assessed in three consecutive testing periods of 33 exams each | ||
520 | |a RESULTS: A progressive improvement in concordance was observed for all IUS findings from Period 1 to Period 3, overall and for both groups of trainees, although those with experience in abdominal ultrasound had faster learning curves. The minimum number of examinations required to achieve concordance with the expert operator for detecting increased bowel wall thickness was 84 and detecting bowel dilatation was 79. However, a minimum of 97 examinations was necessary to achieve concordance for detecting intra-abdominal complications, considered an advanced IUS competence | ||
520 | |a CONCLUSION: Basic competence in IUS can be acquired with relatively few examinations, while advanced competence requires more extensive training, particularly for gastroenterologists without abdominal ultrasound experience | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Bowel ultrasound | |
650 | 4 | |a Crohn's disease (CD) | |
650 | 4 | |a Gastrointestinal ultrasound | |
650 | 4 | |a Inflammatory bowel disease (IBD) | |
650 | 4 | |a Ulcerative colitis (UC) | |
700 | 1 | |a Saibeni, Simone |e verfasserin |4 aut | |
700 | 1 | |a Vernero, Marta |e verfasserin |4 aut | |
700 | 1 | |a Furfaro, Federica |e verfasserin |4 aut | |
700 | 1 | |a Monteleone, Michela |e verfasserin |4 aut | |
700 | 1 | |a Ribaldone, Davide |e verfasserin |4 aut | |
700 | 1 | |a Fiorino, Gionata |e verfasserin |4 aut | |
700 | 1 | |a Friedman, Antony B |e verfasserin |4 aut | |
700 | 1 | |a Armuzzi, Alessandro |e verfasserin |4 aut | |
700 | 1 | |a Scalvini, Davide |e verfasserin |4 aut | |
700 | 1 | |a Maconi, Giovanni |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver |d 2000 |g (2024) vom: 05. Feb. |w (DE-627)NLM108968790 |x 1878-3562 |7 nnns |
773 | 1 | 8 | |g year:2024 |g day:05 |g month:02 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.dld.2024.01.192 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |j 2024 |b 05 |c 02 |