Sustainable reduction of phone-call interruptions by 35% in a medical imaging department using an automatic voicemail and custom call redirection system

Copyright © 2024. Published by Elsevier Inc..

BACKGROUND: Have you ever been in the trenches of a complicated study only to be interrupted by a not-so urgent phone-call? We were, repeatedly- unfortunately.

PURPOSE: To increase productivity of radiologists by quantifying the main source of interruptions (phone-calls) to the workflow of radiologists, and too assess the implemented solution.

MATERIALS AND METHODS: To filter calls to the radiology consultant on duty, we introduced an automatic voicemail and custom call redirection system. Thus, instead of directly speaking with radiology consultants, clinicians were to first categorize their request and dial accordingly: 1. Inpatient requests, 2. Outpatient requests, 3. Directly speak with the consultant radiologist. Inpatient requests (1) and outpatient requests (2) were forwarded to MRI technologists or clerks, respectively. Calls were monitored in 15-minute increments continuously for an entire year (March 2022 until and including March 2023). Subsequently, both the frequency and category of requests were assessed.

RESULTS: 4803 calls were recorded in total: 3122 (65 %) were forwarded to a radiologist on duty. 870 (18.11 %) concerned inpatients, 274 (5.70 %) outpatients, 430 (8.95 %) dialed the wrong number, 107 (2.23 %) made no decision. Throughout the entire year the percentage of successfully avoided interruptions was relatively stable and fluctuated between low to high 30 % range (Mean per month 35 %, Median per month 34.45 %).

CONCLUSIONS: This is the first analysis of phone-call interruptions to consultant radiologists in an imaging department for 12 continuous months. More than 35 % of requests did not require the input of a specialist trained radiologist. Hence, installing an automated voicemail and custom call redirection system is a sustainable and simple solution to reduce phone-call interruptions by on average 35 % in radiology departments. This solution was well accepted by referring clinicians. The installation required a one-time investment of only 2h and did not cost any money.

Medienart:

E-Artikel

Erscheinungsjahr:

2024

Erschienen:

2024

Enthalten in:

Zur Gesamtaufnahme - volume:53

Enthalten in:

Current problems in diagnostic radiology - 53(2024), 2 vom: 26. März, Seite 246-251

Sprache:

Englisch

Beteiligte Personen:

Achangwa, Ngwe Rawlings [VerfasserIn]
Nierobisch, Nathalie [VerfasserIn]
Ludovichetti, Riccardo [VerfasserIn]
Negrão de Figueiredo, Giovanna [VerfasserIn]
Kupka, Michael [VerfasserIn]
De Vere-Tyndall, Anthony [VerfasserIn]
Frauenfelder, Thomas [VerfasserIn]
Kulcsar, Zsolt [VerfasserIn]
Hainc, Nicolin [VerfasserIn]

Links:

Volltext

Themen:

Cost effective
Error
Interruption
Journal Article
Medical imaging
Patient safety
Radiology
Report
Sustainable

Anmerkungen:

Date Completed 05.03.2024

Date Revised 05.03.2024

published: Print-Electronic

Citation Status MEDLINE

doi:

10.1067/j.cpradiol.2024.01.004

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM367812207