Effect of ultrafiltration on whole blood coagulation profile during cardiopulmonary bypass in cardiac surgery : a retrospective analysis
BACKGROUND: Ultrafiltration (UF) would enhance coagulation profiles by concentrating coagulation elements during cardiopulmonary bypass (CPB) for cardiac surgery.
METHODS: We retrospectively reviewed electronic medical records of 75 patients who had undergone cardiac surgery with rotational thromboelastometry-based coagulation management in a university hospital and analyzed the UF-induced changes in the maximum clot firmness (MCF) of extrinsically activated test with tissue factor (EXTEM) during CPB in 30 patients.
RESULTS: The median volume of filtered-free water was 1,350 ml, and median hematocrit was significantly increased from 22.5% to 25.5%. As the primary measure, UF significantly increased the median MCF-EXTEM from 48.0 mm to 50.5 mm (P = 0.015, effect size r = 0.44). The area under the receiver operating characteristic curve pre-UF MCF-EXTEM for discrimination of any increase of MCF-EXTEM after applying UF was 0.89 (95% CI [0.77, 1.00], P < 0.001), and its cut-off value was 50.5 mm (specificity of 81.8% and sensitivity of 84.2% in Youden's J statistic). In the secondary analyses using the cut-off value, UF significantly increased the median MCF-EXTEM from 40.5 mm to 42.5 mm in 18 patients with pre-UF MCF-EXTEM ≤ 50.5 mm. However, it did not increase MCF-EXTEM in 12 patients with pre-UF MCF-EXTEM > 50.5 mm. There was a significant interaction between pre-UF MCF-EXTEM values and applying UF (P < 0.001 for the subgroup, P = 0.046 for UF, P = 0.003 for interaction).
CONCLUSIONS: Applying UF improved clot firmness, and the improvement was more pronounced when pre-UF MCF-EXTEM had been reduced during CPB.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2024 |
---|---|
Erschienen: |
2024 |
Enthalten in: |
Zur Gesamtaufnahme - volume:77 |
---|---|
Enthalten in: |
Korean journal of anesthesiology - 77(2024), 2 vom: 18. Apr., Seite 236-245 |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Lee, Jaemoon [VerfasserIn] |
---|
Links: |
---|
Themen: |
Blood coagulation |
---|
Anmerkungen: |
Date Completed 02.04.2024 Date Revised 03.04.2024 published: Print-Electronic Citation Status MEDLINE |
---|
doi: |
10.4097/kja.23698 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM367775522 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM367775522 | ||
003 | DE-627 | ||
005 | 20240403235326.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240130s2024 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.4097/kja.23698 |2 doi | |
028 | 5 | 2 | |a pubmed24n1363.xml |
035 | |a (DE-627)NLM367775522 | ||
035 | |a (NLM)38287212 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Lee, Jaemoon |e verfasserin |4 aut | |
245 | 1 | 0 | |a Effect of ultrafiltration on whole blood coagulation profile during cardiopulmonary bypass in cardiac surgery |b a retrospective analysis |
264 | 1 | |c 2024 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Completed 02.04.2024 | ||
500 | |a Date Revised 03.04.2024 | ||
500 | |a published: Print-Electronic | ||
500 | |a Citation Status MEDLINE | ||
520 | |a BACKGROUND: Ultrafiltration (UF) would enhance coagulation profiles by concentrating coagulation elements during cardiopulmonary bypass (CPB) for cardiac surgery | ||
520 | |a METHODS: We retrospectively reviewed electronic medical records of 75 patients who had undergone cardiac surgery with rotational thromboelastometry-based coagulation management in a university hospital and analyzed the UF-induced changes in the maximum clot firmness (MCF) of extrinsically activated test with tissue factor (EXTEM) during CPB in 30 patients | ||
520 | |a RESULTS: The median volume of filtered-free water was 1,350 ml, and median hematocrit was significantly increased from 22.5% to 25.5%. As the primary measure, UF significantly increased the median MCF-EXTEM from 48.0 mm to 50.5 mm (P = 0.015, effect size r = 0.44). The area under the receiver operating characteristic curve pre-UF MCF-EXTEM for discrimination of any increase of MCF-EXTEM after applying UF was 0.89 (95% CI [0.77, 1.00], P < 0.001), and its cut-off value was 50.5 mm (specificity of 81.8% and sensitivity of 84.2% in Youden's J statistic). In the secondary analyses using the cut-off value, UF significantly increased the median MCF-EXTEM from 40.5 mm to 42.5 mm in 18 patients with pre-UF MCF-EXTEM ≤ 50.5 mm. However, it did not increase MCF-EXTEM in 12 patients with pre-UF MCF-EXTEM > 50.5 mm. There was a significant interaction between pre-UF MCF-EXTEM values and applying UF (P < 0.001 for the subgroup, P = 0.046 for UF, P = 0.003 for interaction) | ||
520 | |a CONCLUSIONS: Applying UF improved clot firmness, and the improvement was more pronounced when pre-UF MCF-EXTEM had been reduced during CPB | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a Blood coagulation | |
650 | 4 | |a Cardiac surgical procedures | |
650 | 4 | |a Cardiopulmonary bypass | |
650 | 4 | |a Retrospective studies | |
650 | 4 | |a Thoracic surgery | |
650 | 4 | |a Thrombelastography | |
650 | 4 | |a Ultrafiltration. | |
700 | 1 | |a Lee, Dong-Kyu |e verfasserin |4 aut | |
700 | 1 | |a Kwon, Won-Kyoung |e verfasserin |4 aut | |
700 | 1 | |a Lee, Sookyung |e verfasserin |4 aut | |
700 | 1 | |a Oh, Chung-Sik |e verfasserin |4 aut | |
700 | 1 | |a Görlinger, Klaus |e verfasserin |4 aut | |
700 | 1 | |a Kim, Tae-Yop |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Korean journal of anesthesiology |d 2009 |g 77(2024), 2 vom: 18. Apr., Seite 236-245 |w (DE-627)NLM198358962 |x 2005-7563 |7 nnns |
773 | 1 | 8 | |g volume:77 |g year:2024 |g number:2 |g day:18 |g month:04 |g pages:236-245 |
856 | 4 | 0 | |u http://dx.doi.org/10.4097/kja.23698 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 77 |j 2024 |e 2 |b 18 |c 04 |h 236-245 |