Testing the limits of multiplex respiratory virus assays for SARS-CoV-2 at high cycle threshold values : Comparative performance of cobas 6800/8800 SARS-CoV-2 & Influenza A/B, Xpert Xpress SARS-CoV-2/Flu/RSV, and cobas Liat SARS-CoV-2 & Influenza A/B

© Association of Medical Microbiology and Infectious Disease Canada (AMMI Canada), 2023..

Background: Multiplex real-time RT-PCR assays for respiratory pathogens are valuable tools to optimize laboratory workflow and turnaround time. At a time when resurgence of influenza and respiratory syncytial virus (RSV) cases have been widely observed along with continued transmission of SARS-CoV-2, timely identification of all circulating respiratory viruses is crucial. This study evaluates the detection of low viral loads of SARS-CoV-2 by four multiplex molecular assays: Roche cobas 6800/8800 SARS-CoV-2 & Influenza A/B Test, Cepheid Xpert Xpress SARS-CoV-2/Flu/RSV, cobas Liat SARS-CoV-2 & Influenza A/B, and a laboratory-developed test (LDT).

Methods: Retrospective upper respiratory tract specimens positive for various respiratory viruses at a range of cycle threshold (Ct) values (18-40) were tested by four multiplex assays. Positive and negative percent agreement (PPA and NPA) with validated RT-PCR assays were calculated.

Results: A total of 82 samples were assessed, with discordant results observed in a portion of the samples (10/82, 12.2%) where Ct values were >33. The majority of the discordant results (6/10, 60%) were false negatives. Overall, PPA was 100% (58/58) for cobas 6800, 97.4% (38/39) for GeneXpert, 100% (17/17) for Liat, and 90.5% (57/63) for the LDT. PPA for the LDT increased to 92.1% after manual review of amplification curves.

Conclusions: Commercial multiplex respiratory virus assays have good performance for samples with medium to high viral loads (Ct values <33). Laboratories should consider appropriate test result review and confirmation protocols to optimize sensitivity, and may consider reporting samples with additional interpretive comments when low viral loads are detected.

Medienart:

E-Artikel

Erscheinungsjahr:

2024

Erschienen:

2024

Enthalten in:

Zur Gesamtaufnahme - volume:8

Enthalten in:

Journal of the Association of Medical Microbiology and Infectious Disease Canada = Journal officiel de l'Association pour la microbiologie medicale et l'infectiologie Canada - 8(2024), 4 vom: 15. Jan., Seite 328-335

Sprache:

Englisch

Beteiligte Personen:

Matic, Nancy [VerfasserIn]
Lawson, Tanya [VerfasserIn]
Ritchie, Gordon [VerfasserIn]
Lowe, Christopher F [VerfasserIn]
Romney, Marc G [VerfasserIn]

Links:

Volltext

Themen:

Journal Article
Multiplex
Panel
Respiratory
SARS-CoV-2

Anmerkungen:

Date Revised 23.01.2024

published: Electronic-eCollection

Citation Status PubMed-not-MEDLINE

doi:

10.3138/jammi-2022-0039

funding:

Förderinstitution / Projekttitel:

PPN (Katalog-ID):

NLM367411172