Validation of Quantitative Flow Ratio-Derived Virtual Angioplasty with Post-Angioplasty Fractional Flow Reserve-The QIMERA-I Study
Background: Quantitative flow ratio (QFR) virtual angioplasty with pre-PCI residual QFR showed better results compared with an angiographic approach to assess post-PCI functional results. However, correlation with pre-PCI residual QFR and post-PCI fractional flow reserve (FFR) is lacking. Methods: A multicenter prospective study including consecutive patients with angiographically 50-90% coronary lesions and positive QFR results. All patients were evaluated with QFR, hyperemic and non-hyperemic pressure ratios (NHPR) before and after the index PCI. Pre-PCI residual QFR (virtual angioplasty) was calculated and compared with post-PCI fractional flow reserve (FFR), QFR and NHPR. Results: A total of 84 patients with 92 treated coronary lesions were included, with a mean age of 65.5 ± 10.9 years and 59% of single vessel lesions being the left anterior descending artery in 69%. The mean vessel diameter was 2.82 ± 0.41 mm. Procedural success was achieved in all cases, with a mean number of implanted stents of 1.17 ± 0.46. The baseline QFR value was 0.69 ± 0.12 and baseline FFR and NHPR were 0.73 ± 0.08 and 0.82 ± 0.11, respectively. Mean post-PCI FFR increased to 0.87 ± 0.05 whereas residual QFR had been estimated as 0.95 ± 0.05, showing poor correlation with post-PCI FFR (0.163; 95% CI:0.078-0.386) and low diagnostic accuracy (30.9%, 95% CI:20-43%). Conclusions: In this analysis, the results of QFR-based virtual angioplasty did not seem to accurately correlate with post-PCI FFR.
Medienart: |
E-Artikel |
---|
Erscheinungsjahr: |
2023 |
---|---|
Erschienen: |
2023 |
Enthalten in: |
Zur Gesamtaufnahme - volume:11 |
---|---|
Enthalten in: |
Journal of cardiovascular development and disease - 11(2023), 1 vom: 31. Dez. |
Sprache: |
Englisch |
---|
Beteiligte Personen: |
Amat-Santos, Ignacio J [VerfasserIn] |
---|
Links: |
---|
Themen: |
Coronary physiology |
---|
Anmerkungen: |
Date Revised 28.01.2024 published: Electronic Citation Status PubMed-not-MEDLINE |
---|
doi: |
10.3390/jcdd11010014 |
---|
funding: |
|
---|---|
Förderinstitution / Projekttitel: |
|
PPN (Katalog-ID): |
NLM367393778 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLM367393778 | ||
003 | DE-627 | ||
005 | 20240128231957.0 | ||
007 | cr uuu---uuuuu | ||
008 | 240122s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/jcdd11010014 |2 doi | |
028 | 5 | 2 | |a pubmed24n1273.xml |
035 | |a (DE-627)NLM367393778 | ||
035 | |a (NLM)38248884 | ||
035 | |a (PII)14 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 1 | |a Amat-Santos, Ignacio J |e verfasserin |4 aut | |
245 | 1 | 0 | |a Validation of Quantitative Flow Ratio-Derived Virtual Angioplasty with Post-Angioplasty Fractional Flow Reserve-The QIMERA-I Study |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ƒaComputermedien |b c |2 rdamedia | ||
338 | |a ƒa Online-Ressource |b cr |2 rdacarrier | ||
500 | |a Date Revised 28.01.2024 | ||
500 | |a published: Electronic | ||
500 | |a Citation Status PubMed-not-MEDLINE | ||
520 | |a Background: Quantitative flow ratio (QFR) virtual angioplasty with pre-PCI residual QFR showed better results compared with an angiographic approach to assess post-PCI functional results. However, correlation with pre-PCI residual QFR and post-PCI fractional flow reserve (FFR) is lacking. Methods: A multicenter prospective study including consecutive patients with angiographically 50-90% coronary lesions and positive QFR results. All patients were evaluated with QFR, hyperemic and non-hyperemic pressure ratios (NHPR) before and after the index PCI. Pre-PCI residual QFR (virtual angioplasty) was calculated and compared with post-PCI fractional flow reserve (FFR), QFR and NHPR. Results: A total of 84 patients with 92 treated coronary lesions were included, with a mean age of 65.5 ± 10.9 years and 59% of single vessel lesions being the left anterior descending artery in 69%. The mean vessel diameter was 2.82 ± 0.41 mm. Procedural success was achieved in all cases, with a mean number of implanted stents of 1.17 ± 0.46. The baseline QFR value was 0.69 ± 0.12 and baseline FFR and NHPR were 0.73 ± 0.08 and 0.82 ± 0.11, respectively. Mean post-PCI FFR increased to 0.87 ± 0.05 whereas residual QFR had been estimated as 0.95 ± 0.05, showing poor correlation with post-PCI FFR (0.163; 95% CI:0.078-0.386) and low diagnostic accuracy (30.9%, 95% CI:20-43%). Conclusions: In this analysis, the results of QFR-based virtual angioplasty did not seem to accurately correlate with post-PCI FFR | ||
650 | 4 | |a Journal Article | |
650 | 4 | |a coronary physiology | |
650 | 4 | |a fractional flow reserve | |
650 | 4 | |a quantitative flow ratio | |
650 | 4 | |a virtual angioplasty | |
700 | 1 | |a Marengo, Giorgio |e verfasserin |4 aut | |
700 | 1 | |a Sánchez-Luna, Juan Pablo |e verfasserin |4 aut | |
700 | 1 | |a Cortés Villar, Carlos |e verfasserin |4 aut | |
700 | 1 | |a Rivero Crespo, Fernando |e verfasserin |4 aut | |
700 | 1 | |a Jiménez Díaz, Víctor Alfonso |e verfasserin |4 aut | |
700 | 1 | |a de la Torre Hernández, José María |e verfasserin |4 aut | |
700 | 1 | |a Pérez de Prado, Armando |e verfasserin |4 aut | |
700 | 1 | |a Sabaté, Manel |e verfasserin |4 aut | |
700 | 1 | |a López-Palop, Ramón |e verfasserin |4 aut | |
700 | 1 | |a Vegas Valle, José Miguel |e verfasserin |4 aut | |
700 | 1 | |a Suárez de Lezo, Javier |e verfasserin |4 aut | |
700 | 1 | |a Fernandez Cordon, Clara |e verfasserin |4 aut | |
700 | 1 | |a Gonzalez, Jose Carlos |e verfasserin |4 aut | |
700 | 1 | |a García-Gómez, Mario |e verfasserin |4 aut | |
700 | 1 | |a Redondo, Alfredo |e verfasserin |4 aut | |
700 | 1 | |a Carrasco Moraleja, Manuel |e verfasserin |4 aut | |
700 | 1 | |a San Román, J Alberto |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of cardiovascular development and disease |d 2014 |g 11(2023), 1 vom: 31. Dez. |w (DE-627)NLM248446517 |x 2308-3425 |7 nnns |
773 | 1 | 8 | |g volume:11 |g year:2023 |g number:1 |g day:31 |g month:12 |
856 | 4 | 0 | |u http://dx.doi.org/10.3390/jcdd11010014 |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a GBV_NLM | ||
951 | |a AR | ||
952 | |d 11 |j 2023 |e 1 |b 31 |c 12 |